• Title/Summary/Keyword: $\rho$-power

Search Result 351, Processing Time 0.023 seconds

A Study on the Customer Voltage Characteristic of Distribution System with Large Scale PV (대용량 태양광발전이 연계된 배전계통의 수용가 전압 특성해석에 관한 연구)

  • Kim, Byung-Ki;Ryu, Kyung-Sang;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • This paper deals with the analysis of the customer voltage characteristic in distribution system interconnected with large scale PV system. There would be many power quality issues which are caused by reverse power flow of PV system interconnected with distribution system. In order to analyze the effect of PV system on the customer voltage, detailed modeling method of distribution system and modified modelling method of PV system are proposed using PSCAD/EMTDC in this paper. So far, less than dozens KW of PV system can be simulated with the existing modelling method. Therefore, a new modeling method which can simulate the large scale PV system is proposed by considering the relationship equation on the phase and voltage in the current control algorithm. From the simulation result of proposed modelling method, it is confirmed that an optimal operation method in distribution system is suggested by analyzing the effect of PV system on customer voltage.

A Sensitivity and Performance Analysis for Torque Mode Switching on 2MW Direct Drive Wind Turbine Generator (2MW급 직접구동형 풍력발전기의 풍황 민감도 및 토크모드 스위칭 성능 해석)

  • Rho, Joo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1455-1460
    • /
    • 2014
  • Wind turbine generators were designed on general regulations of wind condition. At real situations, it could be different from the design conditions. There are many control methods and definitions of transient region, because an efficient wind turbine generator control logic is the important matter in generator performance and annual energy production at real conditions. In this document, the power generation sensitivity for wind speed and turbulence intensities was defined to know the sensitive transient region. Wind conditions are applied for the ranges of 7~10m/s mean wind speed and 14~20% turbulence intensity. The sensibility of HR-D86 wind generator was increased in transient region(8~10m/s) on power curve diagram through a torque control to a pitch control. And then GH-bladed simulations was performed for performance analysis of the torque mode switching in transient region on 2MW direct drive wind generator(HR-D86) which is designed IEC class II for onshore. Through the sensitivity and performance analysis, the sensitivity for real wind condition could be the performance index for an wind generator. And the torque mode switching in transient region can increase the mean power generation on HR-D86 wind turbine generator.

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

Design and Implementation of Eco-friendly Power Supply System for Moveable-weir Using PV Module and Li-ion Battery (태양광모듈과 리튬이온전지를 이용한 가동보용 친환경 전원공급장치의 설계 및 구현)

  • Kang, Min-Kwan;Choi, Sung-Sik;Nam, Yang-Hyeon;Lee, Hu-Dong;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.186-193
    • /
    • 2018
  • Generally, it is difficult to operate moveable-weir due to the expensive cost of the facility management and manpower consumption. Also, when it is installed in a remote area, there is a problem that the cost of connection for power system increases as well as the operating cost. Therefore, this paper proposes an optimal design algorithm to replace an existing power system with an Eco-friendly power supply system for movable-weir using PCS, PV module and lithium-ion battery. Also, this paper proposes a modeling method of environment-friendly power supply system for a movable-weir based on the PSCAD/EMTDC S/W and implements 5[kW] prototype environment-friendly power supply system. As a result of the performance test using the S/W modeling and the prototype system, it is confirmed that the proposed system has stable characteristics in the independent operation mode and the interconnection mode.

A Study on the Optimal Distribution toss Management Using toss factor in Power Distribution Systems (분산형전원이 도입된 배전계통의 손실산정기법에 관한 연구)

  • Rho Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.3
    • /
    • pp.231-240
    • /
    • 2005
  • Recently, the needs and concerns for the power loss are increasing according to the energy conservation at the level of the national policies and power utilities's business strategies. Especially, the issue of the power loss is the main factor for the determining the electric pricing rates in the circumstances of the deregulation of electrical industry. However, because of the lacking of management for power loss load factors (LLF) it is difficult to make a calculation for the power loss and to make a decision for the electric rates. And loss factor (k-factor) in korea, which is a most important factor for calculation of the distribution power loss, has been used as a fixed value of 0.32 since the fiscal year 1973, There(ore, this study presents the statistical calculation methods of the loss factors classified by load types and seasons by using the practical data of 65 primary feeders which are selected by proper procedures. Based on the above the algorithms and methods, the optimal method of the distribution loss management classified by facilities such as primary feeders, distribution transformers and secondary feeders is presented. The simulation results show the effectiveness and usefulness of the proposed methods.

  • PDF

Activation of IL-1β, IGF-1 and IGF-2 in Injured Rat Skeletal Muscle by Low Power He-Ne IR Laser and Electrical Stimulation (저출력레이저와 전기자극에 의한 골격근 손상 흰쥐의 IL-1β, IGF-1, IGF-2 활성)

  • Kim, Jong-Soon;Rho, Min-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.251-262
    • /
    • 2008
  • In this study we investigated the effects of physical therapeutic intervention through electromyography, ultrasonographic imaging and changes of the IL-$1{\beta}$, IGF-1 and IGF-2 in skeletal muscle of rats injured experimentally. The twenty Sprague-Dawley male rats were randomly divided into the 4 groups: a normal, a control, a low power laser and a neuromuscular electrical stimulation group. Abnormal spontaneous activities had not been shown, both in normal and skeletal muscle injured rats. The maximum diameter of the calf muscle was significantly increased in the low power laser and neuromuscular electrical stimulation groups compared with control group. The level of the serum IL-$1{\beta}$ was more decreased in the low power laser and neuromuscular electrical stimulation groups than that of control group. The activation level of the IGF-1 and the IGF-2 were significantly higher in the control, low power laser and neuromuscular electrical stimulation groups than that of normal group. However, there was no statistically significant difference among the control, low power laser and neuromuscular electrical stimulation groups.

Economic Evaluation Algorithm of Island Micro-grid for Utility and Independent Power Producer (전력회사와 발전사업자 측면에서 도서지역용 마이크로그리드의 경제성평가 알고리즘)

  • Nam, Yang-Hyum;Lee, Hoo-Dong;Kim, Yu-Rim;Marito, Ferrira;Kim, Mi-Young;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1032-1038
    • /
    • 2017
  • Recently, regulation on carbon emissions has been strengthened according to the new climate change convention (COP21) held in Paris, and then Korea has decided to reduce CO2 emissions by 37% until 2030. As one of countermeasures, the government has energetically performed demonstration projects of island micro-grid including solar power, wind power and energy storage system. However, in order to smoothly introduce island micro-grid, it is a critical issue to carry out the economic evaluation for power utility aspect and independent power producer aspect. Therefore, this paper proposes economic evaluation algorithms of island micro-grid which are based on the present worth method, considering cost and benefit factors in the aspect of both sides. Firstly, in case of power utility this paper proposes algorithm to estimate a period of return on investment according to the introduction capacity of distributed generators replacing diesel generator. And also, in case of independent power producer, this paper proposes evaluation algorithm to estimate weighting factor of SMP and benefit rate based on break-even point related with cost and benefit. From a case study result on real island micro-grid model, it is confirmed that proposed algorithms are useful and practical for the economic evaluation of island micro-grid.

A Study on the Algorithm for Multi-Functional Protection Devices in Distribution Systems with New Energy Sources (신 에너지전원이 연계된 배전계통의 통합 보호기기의 알고리즘 개발에 관한 연구)

  • Yoon, Gi-Gab;Kang, Dae-Hoon;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2253-2260
    • /
    • 2009
  • The typical distribution systems have the power flow from distribution substations (sources) to customers (load) only as one direction. However, in the case where new energy power sources are connected to distribution systems, the output variations of new energy sources to distribution systems, which is so called reverse power flow, may cause the bi-directional power flow. So, the reverse power flow has severe impacts on typical power system, for example power quality problems, protection coordination problems, and so on. Therefore, this paper proposes the algorithm for Multi-functional protection devices in distribution systems in the case where new energy sources are interconnected. The proposed algorithm is verified to show the effectiveness by simulating and experimenting the prototype systems.

Game Algorithm for Power Control in Cognitive Radio Networks (전파 인지 네트워크에서 전력 제어를 위한 게임 알고리즘)

  • Rho, Chang-Bae;Halder, N.;Song, Ju-Bin
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.201-207
    • /
    • 2009
  • Recently effective spectrum resource technologies have been studied using a game theorectical approach for cognitive radio networks. Radio resource management is required an effective scheme because the performance of a radio communication system much depends on it's effectiveness. In this paper, we suggest a game theoretical algorithm for adaptive power control which is required an effect scheme in cognitive radio networks. It will be a distributed network. In the network distributed cognitive radio secondary users require an adaptive power control. There are many results which are suggested some possibility of game theoretical approaches for communication resource sharing. However, we suggest a practical game algorithm to achieve Nash equilibrium of all secondary users using a Nash equilibrium theorem in this paper. Particularly, a game model was analyzed for adaptive power control of a cognitive radio network, which is involved in DSSS (Direct Sequence Spread Spectrum) techniques. In case of K=63 and N=12 in the DSSS network, the number of iteration was less than maximum 200 using the suggested algorithm.

  • PDF

Study of a Photovoltaic System as an Emergency Power Supply for Offshore Plant Facilities (해양플랜트 설비의 비상전원공급을 위한 태양광 발전시스템 연구)

  • Choi, Gun Hwan;Lee, Byung Ho;Jung, Rho-Taek;Shin, Kyubo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.279-286
    • /
    • 2018
  • The use of eco-friendly energy in the offshore plant system is expanding because conventional generators are operated by fossil fuel or natural gas. Eco-friendly energy, which replaces existing power generation methods, should be capable of generating the power for lighting protection equipment, airborne fault indication, parameter measurement, and others. Most of the eco-friendly energy used in offshore plant facilities is solar and wind power. In the case of using photovoltaic power, because the structure must be constructed based as flat solar panels, it can be damaged easily by the wind. Therefore, there is a need for a new generation system composed of a spherical structure that does not require a separate structure and is less influenced by the wind. Considering these characteristics, in this study we designed, fabricated, and tested a unit that could provide the most efficient spherical photovoltaic power generation considering wind direction and wind pressure. Our test results indicated that the proposed system reduced costs because it did not require any separate structure, used eco-friendly energy, reduced carbon dioxide emissions, and expanded the proportion of eco-friendly energy use by offshore plant facilities.