• Title/Summary/Keyword: zone method

Search Result 3,268, Processing Time 0.03 seconds

A Study on the Minimum Zone Algorithm for the Calculation of Roundness (진원도 계산을 위한 Minimum Zone 알고리즘 연구)

  • 이응석;김종길;신양기
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.156-161
    • /
    • 2000
  • Least Squares and Minimum Zone method are known for obtaining a datum or a continuous approximate function of measured data. This study is for a Minimum Zone algorithm for a circle, which is useful to obtain the exact roundness from the reference circle of measured data. The proposed method is compared with the Least Squares Limacon method and Chrystal-Peirce algorithm. A computational algorithm for the Minimum Zone circle is suggested and results in less roundness than the other two methods. This Minimum Zone circle method will be used for other geometrical measured data, such as plane or sphere for obtaining the exact flatness or sphericity.

  • PDF

Drawing of Concentric Zone Border Line using Landsat TM Images

  • Sato, Kiyotada;Yokoyama, Ryuzo
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.13-14
    • /
    • 2003
  • Burgess?s concentric zone model is a famous theory in the geography of city. However, the zone border line drawing method was uncertain. We have developed the method of drawing the border using land use images.

  • PDF

Evaluation of the Smear Zone by Numerical Analysis Method (수치해석에 의한 스미어 존 평가)

  • Kang, Yun;Nam, Yelwoo;Lee, Seombeom;Kim, Hongtaek
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • The vertical drain method recently being used in Korea is divided into the sand drain method, the pack drain method, the paper drain method, and the PBD method according to the drainage. However, these methods generate the disturbed zone called the smear zone when the drainage is penetrated into the in-situ ground. The characteristics of the smear zone generated cause the problems that the coefficient of permeability decreases and the consolidation time becomes longer than expected in the design. Although the size of the smear zone is a very important factor directly influencing the degree of consolidation, in the existing studies, the general value for the size of the smear zone proposed has been used in the design. However, the size of the smear zone proposed by the existing studies cause a loss of economical efficiency because of the inaccuracy of the design. Hence, in this study, the characteristics on the size of the smear zone were analyzed by carrying out the three dimensional numerical analysis and the method to determine the conversion size of the smear zone considering the change of the coefficient of permeability was proposed in order to consider the change of the coefficient of permeability in the actual design.

  • PDF

A Study on Inner Zone Trip Estimation Method in Gravity Model (중력모형에서 존내 분포통행 예측방법에 관한 연구)

  • Ryu, Yeong Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.763-769
    • /
    • 2006
  • Gravity Model estimates target year's distributed trips using three variables like as origin zone's trip production, destination zone's trip attraction and traffic impedance between origin zone centroid and destination zone centroid. Estimating inner zone trip by gravity model is impossible because traffic impedance of inner zone has "0" value. So till today, for estimating inner zone trips, other methods like growth factor model are used. This study proposed inner zone trip estimation method that calculates inner zone's traffic impedance using established gravity model and estimates inner zone trips by putting calculated traffic impedance into the gravity model. 1988 year's surveyed O-D as basic year's O-D, proposed method's and existing methods(growth factor method and regression model)'s estimated results of 1992 year's and 2004 year's were compared with each year's real O-D by $x^2$, RMSE, Correlation coefficient. And resulted that the proposed method is superior than other existing methods.

A Study on Hardening Zone by Vacuum Consolidation Drainage Method (진공압밀 배수공법에 의한 Hardening Zone에 대한 연구)

  • Chung, Youn-In;Kim, Hee-Joong;Chang, Chun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.197-205
    • /
    • 2004
  • The relationships were studied between the range of hardening zone and the intensity of vacuum pressure in case of applying vacuum consolidation drainage method for soil improvement. A testing apparatus was made to measure the range of hardening zone varying the water content and the intensity of vacuum pressure for 3 different the highly compressible dredged clays(Gwangyang, Busan and Mokpo). In case of applying high vacuum pressure, the hardening zone is not spreaded as compared to low vacuum pressure because of the clogging of drainage and developed hardening zone near the drainage.

A Study on the Ultrnsonic Distance Amplitude Characteristics Curve for Weld Defects Evaluation of Titanium Weld Zone (티타늄 용접부의 용접결함평가를 위한 초음파거리진폭특성곡선에 관한 연구)

  • Yi, Won;Park, Hee-Dong;Yun, In-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • This study proposes integrity evaluation method of weld zone in titanium using titanium distance amplitude characteristics curve(TDACC) and ultrasonic signals. For these purposes, the ultrasonic signals for porosity defects of weld zone in titanium are acquired in the type of time series data and echo strength. 4 lines in the DACC indicated damage evaluation standard of weld zone in titanium. The acquired ultrasonic signals agree fairly well with the measured results of reference block and sensitivity block(defect location, bean1 propagation distance, echo strength, etc). The proposed TDACC in this study agree fairy well with the measured results of weld zone in titanium(weld defects as porosity). The proposed TDACC in this study can be used for integrity evaluation of weld zone in titanium.

Estimation of Fracture Toughness of Dual Phase Steel by J Integral (J積分法 을 이용한 複合組織鋼 의 破壞靭性評價)

  • 김정규;오재민;이완익
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.5
    • /
    • pp.469-475
    • /
    • 1984
  • In dual phase steel composed of martensite and ferrite which are different in deformation behavior, the quantitative estimation of fracture toughness is investigated by the R-curve method and the stretched zone method of JSME Sool. In the homogeneous material J$_{IC}$ value measured by the R-curve method and the stretched zone method are almost equivalent each other, but in the inhomogeneous material J$_{IC}$ value by the stretched zone method is overestimated than that by the R-curve method. Such a overestimation for the J$_{IC}$ is due to the continuous plastic blunting of ferrite after the stretched zone width in martensite reached critical value which overmeasures the critical stretched zone width.width.

Strain Characteristics of Reinforcing materials in the transition zone of slopes (사면의 변이영역에서 보강재의 변형률 특성)

  • 김경태;장대수;장기태;한희수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.119-127
    • /
    • 2003
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are‘active zone’and‘passive zone’. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF

Advanced Indoor Zone Detection with Bluetooth and Ultrasound of Smartphone (스마트폰의 블루투스와 초음파를 이용한 향상된 실내 영역 결정)

  • Kwon, Jin-Se;Lee, Je-Min;Kim, Hyung-Shin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.3
    • /
    • pp.135-141
    • /
    • 2016
  • Indoor zone-based services have continuously become popular by increased prevalence of smartphones. Bluetooth and ultrasound can be used for zone detection. However, bluetooth does not guarantee precise zone detection if the signal degrades due to the obstacles. Ultrasound can be easily forged by recording sound on the smartphone. For that reason, zone detection based on ultrasound has a security hole. To remedy each limitation, we propose an advanced zone detection method, that combines bluetooth and ultrasound. An authentication server issues a one-time password to the user over bluetooth. The user generates an ultrasound signal that encodes the password. In this manner, the proposed method ensures secure and accurate zone detection.

Strain Distribution of transition zone in a nailed wall (네일로 보강된 구조물에서의 변이영역과 변형률 분포)

  • 장기태;남궁한;유병선;김경태;권병근;이선경
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.235-239
    • /
    • 2000
  • For the calculation of internal stability, the hypothesis in conventional design is on the basis of two distinct zones, which are 'active zone' and 'passive zone'. This means that there is an abrupt discontinuous transition from active to passive states across a potential failure line. The existence of a discontinuity of this nature appears physically unreasonable, especially from kinematic considerations. A series of pull-out model tests was undertaken from a wall being rotated about the toe to find the strain distribution mobilized from near the wall face into the deep, stable zone through the centre plane. With this finding of transition zone, the objective of study is aiming at identifying the likely effect of this zone in designing method by comparing with the prevailing design method.

  • PDF