Purpose: The purpose of this study was to evaluate the stability of abutment screws used with the zirconia fixture-based implant system and compare them with those used with the existing titanium fixture system via the finite element method. Methods: A single implant-supported restoration was designed for the finite element analysis. A universal analysis program was used to set 8 occlusal points along the direction to the long axis of the implant, and an occlusal load of 700 N was applied. Results: In all models (Zir and Ti-fixture model), the screw threads presented with the highest von Mises stress (VMS) values, whereas the head and end presented with the lowest VMS values. The VMS of the screw used in the zirconia-fixture model was 5.97% lower than that used in the titanium-fixture model (261.258 vs. 276.911 MPa, respectively) despite statistical significance. Furthermore, the zirconia fixture (352.912 MPa) had a higher stress value (8.42%) than the titanium fixture (332.331 MPa). In a completely tightened titanium fixture implant system, the stress was concentrated in the implant-abutment connection interface, the zirconia fixture presented with a stable stress distribution. Conclusion: Although the zirconia fixture demonstrated a high VMS value, owing to the stiffness and elasticity coefficients of the material, the stress generated in the abutment screws was similar in all models. In conclusion, the zirconia fixture-based implant system presented with a more stable stress distribution in the abutment screws than the titanium fixture-based implant system.
최근 심미 보철을 위해 높은 강도와 정밀도를 가지면서 동시에 자연치와 유사한 상아질 색을 구현할 수 있는 세라믹 계열의 지르코니아 임플란트 지대주가 보철 재료로서 각광을 받고 있다. 이에 본 연구에서는 삼차원적 유한요소응력분석을 이용하여 기존의 티타늄 소재의 임플란트 지대주와 지르코니아 소재의 임플란트 지대주의 응력분포비교를 통해 지르코니아 임플란트 지대주의 기계적 안정성을 간접적으로 확인하고자 하였다. 악골에 식립된 internal conical joint type과 external butt joint type의 임플란트 매식체에 티타늄 임플란트 지대주 또는 지르코니아 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 유한요소모형을 설계하였다. 교합면 중심으로부터 3mm 편측에 수직 방향으로 250N의 하중을 인가하여 교합력에 의해 임플란트 지대주에서 발생하는 등가응력분포를 분석하였다. 유한요소분석결과 지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 응력 분포는 유사하게 관찰되었으나 최대등가응력은 임플란트 연결 방식에 상관없이 티타늄 임플란트 지대주에 비해 지르코니아 임플란트 지대주가 약 15% 정도 높게 나타났다. 그럼에도 불구하고 티타늄에 비해 지르코니아의 더 높은 기계적 강도를 고려해 볼 때 임상에서도 기존의 티타늄 임플란트 지대주와 마찬가지로 지르코니아 임플란트 지대주도 임상적인 기계적 안정성을 가질 것으로 생각된다.
목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.
Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.
Purpose: The present study was performed to investigate the effect of abutment inclined angle on the marginal fit of zirconia all-ceramic crown. Methods: The Ti abutments with 3 different inclined angle($2^{\circ}$, $4^{\circ}$ and $6^{\circ}$) were fabricated. The zirconia copings were fabricated for each abutment by using dental CAD/CAM system. The manufactured zirconia copings were duplicated through silicone replica technique, and a replicated specimen was sectioned in the center of bucco-lingual and mesio-distal axial to measure the marginal fit by using a stereo microscope. The results were analyzed using a one-way ANOVA with SPSS 22.0 for Windows(${\alpha}=0.05$). Results: On the bucco-lingual axial, marginal fit was the RL3($41.5{\pm}3.4{\mu}m$), RL2($44.3{\pm}4.3{\mu}m$) and RL1($47.5{\pm}5.7{\mu}m$), respectively. On the mesio-distal axial, marginal fit was the RL3($41.1{\pm}3.7{\mu}m$), RL2($45.7{\pm}5.3{\mu}m$) and RL1($46.2{\pm}4.5{\mu}m$), respectively. One-way ANOVA showed statistically significant difference between groups for marginal fit(p<0.05). Conclusion: For marginal fit of the abutments inclined angle, RL3 specimen was superior. The abutment inclined angle had influence on marginal fit of the zirconia copings. The marginal fit of each group were within clinically acceptable range.
The full sintering process of zirconia has some extent of shrinkage and the custom abutment design should consider the pre-compensation volume of the shape. In this paper, we concentrated to reveal the asymmetric sintering characteristics. The circular profile of all six samples were measured using the three dimensional coordinate machine. After the full sintering process, the profiles were measured again. The roundness were compared to those of the original shapes and the percent of shrinkage were calculated. On the other hand, surface roughness was also investigated after the full sintering process. The final average surface roughness was improved by the sintering of the machined zirconia surface.
Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
The Journal of Advanced Prosthodontics
/
제11권2호
/
pp.105-111
/
2019
PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.
목적: 본 연구의 목적은 세 가지 높이를 가진 티타늄 베이스 임플란트 지대주에서 세 종류의 시멘트가 지르코니아 수복물에서 가지는 제거력을 비교하는 것이다. 연구 재료 및 방법:. 90개의 직경 4.0 mm 임플란트 아날로그가 레진 블록에 식립되었다. 이후 3 mm, 5 mm, 7 mm의 높이를 가지도록 임플란트 지대주를 30개씩 제작하였고, 각 지대주를 스캔하여 지르코니아 수복물 시편을 제작하였다. 임시 시멘트(TB), 반영구 시멘트(CI), 영구 시멘트(FC)를 각자 제조사의 지시에 따라 지대주에 접착하였다. 제작된 90개의 시편은 만능시험기에서 제거력을 시험하였으며, 모든 제거력은 부하량이 하락하기 직전 가장 높은 값에서 측정되었다. 통계 분석은 지대주의 높이, 시멘트의 종류에 대해 각각 Kruskal-Wallis test (P = 0.05) 후 Mann-Whitney U test (P = 0.0167)로 사후 검정 시행하였다. 결과: 임플란트 지대주의 높이에 상관없이 TB에 비해 FC의 제거력이 높았다. CI와 FC간에는 3 mm와 7 mm에서는 유의미한 차이가 있었으나 5 mm에서는 유의미한 차이가 없었다. TB와 CI간에는 5 mm에서만 유의미한 차이가 있었다. 결론: 시멘트의 종류는 지르코니아 수복물의 제거력에 유의미한 영향을 끼쳤으나, 임플란트 지대주의 높이는 유의미한 영향을 주지 않았다.
이전부터 사용된 티타늄, 금합금 지대주 및 최근 사용이 급증한 지르코니아 지대주와 임플란트의 계면에 대한 비교 연구와 동적하중이 계면에 미치는 영향에 관한 연구가 많지 않은 실정이다. 본 연구에서 지대주 종류와 동적 하중에 따른 미세간극의 차이를 주사전자현미경 분석을 통하여 비교평가 하였다. USII ${\phi}3.75{\times}11.5mm$ (Osstem Co., Seoul, Korea) 티타늄 임플란트에 티타늄 지대주, 지르코니아 지대주, 주조 금합금 (UCLA plastic) 지대주를 각 군당 7개씩, 30Ncm의 조임회전력으로 연결하였다. 25-250N의 sine형 동적하중을 장축 방향에서 $30^{\circ}$ 경사로 $10^5$회 시행하였다. 하중 전후에 계면의 미세간극을 순측, 구개측, 근심측, 원심측 부위에서 측정하였고, 그 결과 동적 하중으로 인한 통계적 유의성은 없었다. 지대주 종류에 따른 미세간극을 비교한 결과, 동적하중 시행 전후 모두 UCLA 군과 티타늄 군, UCLA 군과 지르코니아 군 사이에 통계적으로 유의한 차이를 보였다(p<0.05). 티타늄 군과 지르코니아 군 사이에는 유의한 차이를 보이지 않았다. UCLA 지대주는 정밀 연삭된 티타늄, 지르코니아 지대주 보다 더 큰 미세간극을 보였고 $10^5$회 동적하중은 미세간극에 영향을 미치지 않았다.
연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.