Acknowledgement
This work was supported by the technology development program (grant number S2910908) funded by the Ministry of SMEs and Startups (MSS, Korea) and research fund offered from Catholic University of Pusan.
References
- de Moura MB, Rodrigues RB, Pinto LM, de Araujo CA, Novais VR, Junior PCS. Influence of screw surface treatment on retention of implant-supported fixed partial dentures. J Oral Implantol. 2017;43:254-260. https://doi.org/10.1563/aaid-joi-D-16-00145
- Moraes SL, Pellizzer EP, Verri FR, Santiago JF Jr, Silva JV. Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios. Comput Methods Biomech Biomed Engin. 2015;18:689-696. https://doi.org/10.1080/10255842.2013.820719
- Quaresma SE, Cury PR, Sendyk WR, Sendyk C. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone. J Oral Implantol. 2008;34:1-6. https://doi.org/10.1563/1548-1336(2008)34[1:afeaot]2.0.co;2
- Lee MK, Kim KJ. Three dimensional finite element analysis of the stress on supporting bone by the abutment materials of dental implant. J Korean Acad Dent Technol. 2018;40:41-47.
- Carvalho MA, Sotto-Maior BS, Del Bel Cury AA, Pessanha Henriques GE. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis. J Prosthet Dent. 2014;112:1096-1102. https://doi.org/10.1016/j.prosdent.2014.03.015
- Brune A, Stiesch M, Eisenburger M, Greuling A. The effect of different occlusal contact situations on periimplant bone stress - a contact finite element analysis of indirect axial loading. Mater Sci Eng C Mater Biol Appl. 2019;99:367-373. https://doi.org/10.1016/j.msec.2019.01.104
- Ahmed WM, Troczynski T, McCullagh AP, Wyatt CCL, Carvalho RM. The influence of altering sintering protocols on the optical and mechanical properties of zirconia: a review. J Esthet Restor Dent. 2019;31:423-430. https://doi.org/10.1111/jerd.12492
- Kelly JR, Denry I. Stabilized zirconia as a structural ceramic: an overview. Dent Mater. 2008;24:289-298. https://doi.org/10.1016/j.dental.2007.05.005
- Ichikawa Y, Akagawa Y, Nikai H, Tsuru H. Tissue compatibility and stability of a new zirconia ceramic in vivo. J Prosthet Dent. 1992;68:322-326. https://doi.org/10.1016/0022-3913(92)90338-B
- Kohal RJ, Weng D, Bachle M, Strub JR. Loaded custommade zirconia and titanium implants show similar osseointegration: an animal experiment. J Periodontol. 2004;75:1262-1268. https://doi.org/10.1902/jop.2004.75.9.1262
- Delgado-Ruiz RA, Gomez Moreno G, Aguilar-Salvatierra A, Markovic A, Mate-Sanchez JE, Calvo-Guirado JL. Human fetal osteoblast behavior on zirconia dental implants and zirconia disks with microstructured surfaces. An experimental in vitro study. Clin Oral Implants Res. 2016;27:e144-e153. https://doi.org/10.1111/clr.12585
- Degidi M, Artese L, Scarano A, Perrotti V, Gehrke P, Piattelli A. Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in periimplant soft tissues around titanium and zirconium oxide healing caps. J Periodontol. 2006;77:73-80. https://doi.org/10.1902/jop.2006.77.1.73
- Hong MH. Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis. J Tech Dent. 2020;42:348-354. https://doi.org/10.14347/jtd.2020.42.4.348
- Gehrke P, Alius J, Fischer C, Erdelt KJ, Beuer F. Retentive strength of two-piece CAD/CAM zirconia implant abutments. Clin Implant Dent Relat Res. 2014;16:920-925. https://doi.org/10.1111/cid.12060
- Shin S, Kim CS, Cho W, Jeong CM, Jeon YC, Yun JH. Mechanical strength of zirconia abutment in implant restoration. J Dent Rehabil Appl Sci. 2009;25:349-360.
- Hwang HJ, Kim SK, Lee JH, Heo SJ, Koak JY, Yoo SY. Comparative analysis between zirconia implant and titanium implant. J Korean Dent Sci. 2012;5:48-53. https://doi.org/10.5856/JKDS.2012.5.2.48
- Belser UC, Grutter L, Vailati F, Bornstein MM, Weber HP, Buser D. Outcome evaluation of early placed maxillary anterior single-tooth implants using objective esthetic criteria: a cross-sectional, retrospective study in 45 patients with a 2- to 4-year follow-up using pink and white esthetic scores. J Periodontol. 2009;80:140-151. https://doi.org/10.1902/jop.2009.080435
- Caglar A, Bal BT, Karakoca S, Aydin C, Yilmaz H, Sarisoy S. Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants. Int J Oral Maxillofac Implants. 2011;26:961-969.
- Verri FR, Cruz RS, Lemos CA, de Souza Batista VE, Almeida DA, Verri AC, et al. Influence of bicortical techniques in internal connection placed in premaxillary area by 3D finite element analysis. Comput Methods Biomech Biomed Engin. 2017;20:193-200. https://doi.org/10.1080/10255842.2016.1209188
- do Nascimento C, Pedrazzi V, Miani PK, Moreira LD, de Albuquerque RF Jr. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface. Clin Oral Implants Res. 2009;20:1394-1397. https://doi.org/10.1111/j.1600-0501.2009.01769.x
- Ha SR, Kim SH, Lee JB, Han JS, Yeo IS, Yoo SH, et al. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement thickness. Ceram Int. 2016;42:14928-14936. https://doi.org/10.1016/j.ceramint.2016.06.133
- Yun MJ, Kim CW, Jeong CM, Seo SU. Three-dimensional finite element analysis for comparison between titanium implant abutment and zirconia implant abutment. J Dent Rehabil Appl Sci. 2011;27:51-61.
- Joos M, Sailer I, Filippi A, Mukaddam K, Rosentritt M, Kuhl S. Stability of screw-retention in two-piece zirconia implants: an in vitro study. Clin Oral Implants Res. 2020;31:607-614. https://doi.org/10.1111/clr.13597
- Lee SH, Lee KB, Hong MH. Finite element analysis of screw-tightening torque applied to custom and conventional abutment. Glob J Health Sci. 2017;9:165-178.
- Kohal RJ, Papavasiliou G, Kamposiora P, Tripodakis A, Strub JR. Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. Int J Prosthodont. 2002;15:189-194.
- Zembic A, Sailer I, Jung RE, Hammerle CH. Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res. 2009;20:802-808. https://doi.org/10.1111/j.1600-0501.2009.01717.x
- Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res. 2004;15:401-412. https://doi.org/10.1111/j.1600-0501.2004.01022.x
- Shadid R, Sadaqa N. A comparison between screw- and cement-retained implant prostheses. A literature review. J Oral Implantol. 2012;38:298-307. https://doi.org/10.1563/AAID-JOI-D-10-00146
- Katsavochristou A, Koumoulis D. Incidence of abutment screw failure of single or splinted implant prostheses: a review and update on current clinical status. J Oral Rehabil. 2019;46:776-786. https://doi.org/10.1111/joor.12817
- Shin HM, Cho W, Jeong CM. Influence of tungsten carbide/carbon coating on the preload and tightening torque of implant abutment screws. J Dent Rehabil Appl Sci. 2009;25:53-59.