• 제목/요약/키워드: zero-loss

검색결과 524건 처리시간 0.023초

Zero-Current-Switching in Full-Bridge DC-DC Converters Based on Activity Auxiliary Circuit

  • Chu, Enhui;Lu, Ping;Xu, Chang;Bao, Jianqun
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.353-362
    • /
    • 2019
  • To address the problem of circulating current loss in the traditional zero-current switching (ZCS) full-bridge (FB) DC/DC converter, a ZCS FB DC/DC converter topology and modulation strategy is proposed in this paper. The strategy can achieve ZCS turn on and zero-voltage and zero-current switching (ZVZCS) turn off for the primary switches and realize ZVZCS turn on and zero-voltage switching (ZVS) turn off for the auxiliary switches. Moreover, its resonant circuit power is small. Compared with the traditional phase shift full-bridge converter, the new converter decreases circulating current loss and does not increase the current stress of the primary switches and the voltage stress of the rectifier diodes. The diodes turn off naturally when the current decreases to zero. Thus, neither reverse recovery current nor loss on diodes occurs. In this paper, we analyzed the operating principle, steady-state characteristics and soft-switching conditions and range of the converter in detail. A 740 V/1 kW, 100 kHz experimental prototype was established, verifying the effectiveness of the converter through experimental results.

Feasible Power Loss Analysis and Estimation of Auxiliary Resonant DC Link Assisted Soft-Switching Inverter with New Zero Vector Generation Method

  • Manabu Kurokawa;Claudio Y. Inaba;M. Rukonuzzaman;Eiji Hiraki;Yoshihiro Konishi;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this paper is to improve power conversion efficiency of three-phase soft-switching voltage-source inverter with an auxiliary resonant dc link (ARDCL) snubber circuit. Firstly, the operation principle of ARDCL snubber circuit is described. Secondly, this paper proposes an effictive generation method of zero voltage vector for three-phase voltage-source soft-switching inverter in power losses in which power losses in the ARDCL snubber circuit can be reduced. In particular, zero voltage holding interval in the inverter DC busline can be controlled due to the new generation scheme of zero voltage vector. Thirdly, a simulator for power loss analysis for power loss characteristics based on actual system, is developed. the validity of developed. The validity of developed simulator of proved with experimental results. Finally, power efficency of three-phase inverter is estimated according to high carrier frequency by using the simulatior.

Novel Zero-Current-Switching (BCS) PWM Switch Cell Minimizing Additional Conduction Loss

  • Park, Hang-Seok;Cho, B.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제12B권1호
    • /
    • pp.37-43
    • /
    • 2002
  • This paper proposes a new zero-current switching (ZCS) pulse-width modulation (PWM) switch cell that has no additional conduction loss of the main switch. In this cell, the main switch and the auxiliary switch turn on and turn off under zero current condition. The diodes commutate softly and the reverse recovery problems are alleviated. The conduction loss and the current stress of the main switch are minimized, since the resonating current for the soft switching does not flow through the main switch. Based on the proposed ZCS PWM switch cell, a new family of dc to dc PWM converters is derived. The new family of ZCS PWM converters is suitable for the high power applications employing IGBTs. Among the new family of dc to dc PWM converters, a boost converter was taken as an example and has been analyzed. Design guidelines with a design example are described and verified by experimental results from the 2.5㎾ prototype boost converter operating at 40KHz.

熱源의 熱損失을 考慮한 內的 可逆사이클의 運轉條件 (The operational conditions of the endoreversible cycle considering the heat loss from the heat source)

  • 김수연;정평석
    • 대한기계학회논문집
    • /
    • 제11권4호
    • /
    • pp.663-667
    • /
    • 1987
  • The conventional model of the heat engine involves the inconsistency with the real engine that the power becomes to be zero at the maximum effectiveness condition. In order to improve this defect, a new model of the heat engine is proposed, in which the heat loss from the heat source is taken into account. In accordance with this model, both the power and effectiveness have their respective extremum with respect to operating conditions, and the effectiveness always becomes to be zero when the power is zero.

전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법 (Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI)

  • 박준철;박찬배;백제훈;곽상신
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-279
    • /
    • 2015
  • A zero vector selection method to reduce switching losses for model predictive control (MPC) of voltage source inverter is proposed. A conventional MPC of voltage source inverter has not been proposed, and a method to select the redundancy of the zero vector is required for this study. In this paper, the redundancy of the zero vectors is selected with generating a zero sequence voltage to reduce switching losses. The zero vector of 2-level inverter is determined by determining sign of the zero sequence voltage. In the proposed method, the quality of the current is retained and switching loss can be reduced compared with the conventional method. This result was verified by P-sim simulation and experiments.

농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 - (A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall -)

  • 박미란;최정만;이정훈
    • 한국농촌건축학회논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.

영전압 영전류 스위칭 방식의 컨버터 (Zero voltage and zero current switched converters)

  • 정규범
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.120-124
    • /
    • 1998
  • In this paper, new zero voltage and zero current switched PWM(Pulse Width Modulated) converters are suggested. The main and auxiliary switch of the converters satisfy soft switching conditions, which are zero voltage or zero current switching of the switches. The switching characteristics of the proposed converters are experimentally verified by boost typed converter, which has 250 kHz switching frequency. For the 250 kHz operation, turn on period of auxiliary switch is about 1/40 for switching period of 4 ${\mu}\textrm{s}$. Therefore, the conduction loss of auxiliary switch is reduced.

  • PDF

보조 스위치의 전도손실을 줄인 영전압 스위칭 방식의 컨버터 (Zero Voltage Switched Converter with Reduced Conduction Loss of Auxiliary Switch)

  • 정규범
    • 전자공학회논문지S
    • /
    • 제36S권2호
    • /
    • pp.131-137
    • /
    • 1999
  • 본 논문에서는 주 스위치가 항상 영전압에서 스위칭하는 새로운 영전압 스위칭 방식의 컨버터를 제안하였다. 기존의 영전압 PWM 컨버터의 공진 인덕터와 포화인덕터은 보조 스위치의 전도손실을 줄이기 위하여 두 개의 포화 인덕터로 대체되었다. 따라서, 제안된 컨버터는 주 스위치가 영전압 스위칭되어 스위칭 손실이 적으며, 주 스위치와 보조 스위치의 전도손실을 줄인 특징이 있다. 주 스위치의 영전압 스위칭 특징을 포함한 특징은 200 kHz에서 실행하여 그 결과를 입증하였다.

  • PDF

Innovative Approaches to Increase the Longevity of PRBs Containing Zero-Valent Iron

  • 이태윤;박재우;최은경;허보연
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.122-124
    • /
    • 2002
  • The removal capacity of zero-valent iron for Cr(Ⅵ) was evaluated using batch kinetic tests. The rate constants for zero-valent iron dramatically increased as initial Cr(Ⅵ) concentration decreased. Generally, the reaction rates of Cr(Ⅵ) with zero-valent iron were faster than that of a biotic degradation of Cr(Ⅵ), and furthermore the reaction rates were inversely proportional to the initial Cr(Ⅵ) concentrations. After certain reaction time elapsed. no further decrease of Cr(Ⅵ) was observed, indicating a loss of iron reactivity. The loss of iron reactivity was primarily due to the passivation of iron surfaces with iron-Cr precipitates, but the reactivity of iron was recovered by adding iron-reducing bacteria. Even though the addition of bacteria itself removed Cr(Ⅵ), the combination of iron-reducing bactera and oxidized iron significantly enhanced the reaction rate for Cr(Ⅵ) removal. The results from column tests also confirmed that the innoculation of iron-reducing bacteria to the column containing completely oxidized iron partially enhanced the recovery of the iron reactivity.

  • PDF

Improved Zero-Current-Switching(ZCS) PWM Switch Cell with Minimum Additional Conduction Losses

  • Park, Hang-Seok;Cho, B.H.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.71-77
    • /
    • 2001
  • This paper proposes a new zero-current switching (ZCS) pulse-width modulation (PWM) switch cell that has no additional conduction loss of the main switch. In this cell, the main switch and the auxiliary switch turn on and turn off under zero current condition. The diodes commutate softly and the reverse recovery problems are alleviated. The conduction loss and the current stress of the main switch are minimized, since the resonating current stress of the main switch are minimized, since the resonating current for the soft switching does not flow through the main switch. Based on the proposed ZCS PWM switch cell, a new family of DC to DC PWM converters is derived. The new family of ZCS PWM converters is suitable for the high power applications employing IGBTs. Among the new family of DC to DB PWM converters, a boost converter was taken as an example and has been analyzed. Design guidelines with a design example are described and verified by experimental results from the 2.5 kW prototype converter operating at 40 kHz.

  • PDF