• 제목/요약/키워드: zero order

검색결과 1,593건 처리시간 0.034초

THE ORDER AND SPEED OF CONVERGENCE FOR THE k-FOLD PSEUDO-OLVER'S METHOD LOCATING A SIMPLE REAL ZERO

  • Kim, Young Ik
    • 충청수학회지
    • /
    • 제19권1호
    • /
    • pp.49-56
    • /
    • 2006
  • A convergence behavior is under investigation near a simple real zero for the k-fold pseudo-Olver's method defined by extending the classical Olver's method. The order of convergence is shown to be at least k+3. The asymptotic error constant is explicitly given in terms of k and the corresponding simple zero. Various numerical examples with a proposed zero-finding algorithm are successfully confirmed with the use of symbolic and computational ability of Mathematica.

  • PDF

Zero-Order 압축 방식에서 ECG 데이터 압축률 예측과 적용에 관한 연구 (A Study on Prediction and Application of ECG Data Compression Rate at Zero-Oder Compression)

  • 안형민;김영길
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.513-516
    • /
    • 1999
  • I here are many kinds of method to compress data. To very simple methods from very complex methods, a kind is various. In this study, the simplest form of the Tolerance-Comparison method, zero-order method is used. Using this method, despite using low speed CPUs, it is possible to compress real time data. So this method is suitable for ECG holler system. In this study, to complement zero-order method, it is needed to develop prediction technique and to research ways to apply the technique.

  • PDF

On Nonovershooting or Monotone Nondecreasing Step Response of Second-Order Systems

  • Kwon, Byung-Moon;Lee, Myung-Eui;Kwon, Oh-Kyu
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.283-288
    • /
    • 2002
  • This paper has shown that the impulse and the unit step responses of 2nd-order systems can be computed by an analytic method. Three different 2nd-order systems are investigated: the prototype system, the system with one LHP(left half plane) real zero and the system with one RHP(right half plane) real zero. It has also shown that the effects of the LHP or the RHP zero are very serious when the zero is getting closer to the origin on the complex plane. Based on these analytic results, this paper has presented two sufficient and necessary conditions for 2nd-order linear SISO(single-input/single-output) stable systems to have the nonovershooting and the monotone nondecreasing step response, respectively. The latter condition can be extended to the sufficient conditions for the monotone nondecreasing step response of high-order systems.

DEFICIENCY ZERO NON-METACYCLIC p-GROUPS OF ORDER LESS THAN 1000

  • Jamali, Ali-Reza
    • Journal of applied mathematics & informatics
    • /
    • 제16권1_2호
    • /
    • pp.303-306
    • /
    • 2004
  • There are 49 non-metacyclic p-groups of order less than 1000 with trivial Schur multiplier. In this paper we give a list of deficiency zero presentations for these groups.

이차 이산시스템의 Peak Overshoot을 최소화하기 위한 영점의 위치 설계 (Design of the Zero Location for Minimizing the Peak Overshoot of Second Order Discrete Systems)

  • 이재석;정태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.512-514
    • /
    • 1999
  • The damping ratio $\zeta$ of a continuous 2nd order response which passes all the points of the discrete response of a 2nd order discrete system(envelope curve) is a function of only the location of the closed-loop pole and ie not at all related to the location of the zero. And the peak overshoot of the envelope curve is uniquely specified by the damping ratio $\zeta$, which is a function of solely the closed-loop pole location, and the angle $\alpha$ which is determined by the relative location of the zero with respect to the closed-loop complex pole. Therefore, if the zero slides on the real axis with the closed-loop complex poles being fixed, then the angle $\alpha$ changes however the damping ratio $\zeta$ does not. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is function of $\alpha$ or the system zero. In this thesis the effects of the relative location of the zero on the system performance of a second order discrete system is studied.

  • PDF

영가철 및 개질 영가철을 이용한 triclosan의 환원분해 특성 (Reduction Characteristics of Triclosan using Zero-valent Iron and Modified Zero-valent Iron)

  • 최정학;김영훈
    • 한국환경과학회지
    • /
    • 제26권7호
    • /
    • pp.859-868
    • /
    • 2017
  • In this study, the reductive dechlorination of triclosan using zero-valent iron (ZVI, $Fe^0$) and modified zero-valent iron (i.e., acid-washed iron (Aw/Fe) and palladium-coated iron (Pd/Fe)) was experimentally investigated, and the reduction characteristics were evaluated by analyzing the reaction kinetics. Triclosan could be reductively decomposed using zero-valent iron. The degradation rates of triclosan were about 50% and 67% when $Fe^0$ and Aw/Fe were used as reductants, respectively, after 8 h of reaction. For the Pd/Fe system, the degradation rate was about 57% after 1 h of reaction. Thus, Pd/Fe exhibited remarkable performance in the reductive degradation of triclosan. Several dechlorinated intermediates were predicted by GC-MS spectrum, and 2-phenoxyphenol was detected as the by-product of the decomposition reaction of triclosan, indicating that reductive dechlorination occurred continuously. As the reaction proceeded, the pH of the solution increased steadily; the pH increase for the Pd/Fe system was smaller than that for the $Fe^0$ and Aw/Fe system. Further, zero-order, first-order, and second-order kinetic models were used to analyze the reaction kinetics. The first-order kinetic model was found to be the best with good correlation for the $Fe^0$ and Aw/Fe system. However, for the Pd/Fe system, the experimental data were evaluated to be well fitted to the second-order kinetic model. The reaction rate constants (k) were in the order of Pd/Fe > Aw/Fe > $Fe^0$, with the rate constant of Pd/Fe being much higher than that of the other two reductants.

이차 이산 시스템의 Peak Overshoot을 최소화하기 위한 영점의 위치 설계 (Design of the Zero Location for Minimizing the Peak Overshoot of Second-Order Discrete Systems)

  • 이재석;정태상
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권11호
    • /
    • pp.483-493
    • /
    • 2002
  • The damping ratio ${\xi}$ of the unit-step response of a second-order discrete system is a function of only the location of the closed-loop poles and is not directly related to the location of the system zero. However, the peak overshoot of the response is the function of both the damping ratio ${\xi}$ and an angle ${\alpha}$, which is the phasor angle of the damped sinusoidal response and is determined by the relative location of the zero with respect to the closed-loop poles. Therefore, if the zero and the open-loop poles are relatively adjusted, through pole-zero cancellation, to maintain the desired (or designed) closed-loop poles, the damping ratio ${\xi}$ will also be maintained, while the angle ${\alpha}$ changes. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is considered as a function of the angle ${\alpha}$ or the system zero location. In this paper the effects of the relative location of the zero on the system performance of a second-order discrete system is studied, and a design method of digital compensator which achieves a minimum peak overshoot while maintaining the desired system mode and the damping ratio of the unit step response is presented.

UNIQUENESS OF q-SHIFT DIFFERENCE-DIFFERENTIAL POLYNOMIAL OF MEROMORPHIC AND ENTIRE FUNCTION WITH ZERO-ORDER

  • V. NAGARJUN;V. HUSNA;VEENA
    • Journal of applied mathematics & informatics
    • /
    • 제41권2호
    • /
    • pp.247-263
    • /
    • 2023
  • In this article, we investigate the uniqueness problem of q-shift difference polynomial of meromorphic (entire) function with zero-order. Consequently, we prove three results with significantly generalize the results of Goutam Haldar.

Theoretical Calculation of Zero Field Splitting of $Mn^{2+}$ Ion in $LiTaO_3$Crystal

  • Yeom, T.H;Lee, S.H
    • Journal of Magnetics
    • /
    • 제6권3호
    • /
    • pp.77-79
    • /
    • 2001
  • The semi-empirical superposition model has been applied to calculate the zero field splitting parameters of $Mn^{2+}$ion in $LiTaO_3$ single crystal, assuming that $Mn^{2+}$ion occupies one of two possible sites: $Li^{l+} \;or\; Ta^{5+}$ site, respectively. The 2nd-order axial zero field splitting parameters are $958\times10^{-4}cm^{-1}\; at\; Li^{1+}$ site and $193\times 10^{-4}cm^{-1} \;at\; Ta^{5+}$ site for $Mn^{2+}$ions. The 4th-order zero field splitting parameters at $Li^{l+} \;and\; Ta^{5+}$ sites are also determined. These calculated zero field splitting parameters are very important to determine the substitutional sites of doped impurity ions in $LiTaO_3$ crystal.

  • PDF

외삽법과 고주파 영차홀드 출력이 포함된 가상 스프링 모델의 안정성 영역 분석 (Stability Analysis for a Virtual Spring Model with an Extrapolation and High-frequency ZOH)

  • 이경노
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.12-17
    • /
    • 2018
  • 가상환경에 대한 현실감을 증강시키기 위해서는 햅틱 시스템의 안정성을 유지하면서 가상환경 모델의 강성을 최대한 크게 할 수 있는 방법이 필요하다. 이에 기존 연구에서 영차홀드 대신 일차홀드를 적용하는 방법이 제시되었고, 영차홀드를 이용할 때보다 가상 스프링의 안정성 영역을 더 크게 확보할 수 있음을 시뮬레이션을 통해 제시했다. 그렇지만 실제로 시스템을 구현하는 측면에서 보면, 영차홀드가 일반적이고 손쉬운 방법이다. 이에 본 논문에서는 영차홀드를 사용하지만, 일차홀드와 동등한 안정성 영역을 확보하기 위한 방법으로 외삽법과 고주파 영차홀드 출력 방법을 제안한다. 제안된 방법에 대한 시뮬레이션을 통해 고주파 영차홀드의 샘플링 주기가 작아질수록 가상 스프링의 안정성 영역이 일차홀드를 적용한 경우와 거의 같아짐을 보였고, 기존 연구에서 제시된 영차홀드만을 적용한 경우보다는 수 배에서 수십 배 안정성 영역이 더 커질수 있음을 보였다. 따라서 제안된 방법을 통해 가상 환경 속 강체에 대한 현실감을 증강시킬 수 있을 것으로 기대된다.