Signal and Noise Analysis of Indirect-Conversion Digital Radiography Detectors Using Linear-systems Transfer Theory (선형시스템 전달이론을 이용한 간접변환방식 디지털 래디오그라피 디텍터의 신호 및 잡음 분석)

  • Yun, Seung-Man;Lim, Chang-Hwy;Han, Jong-Chul;Joe, Ok-La;Kim, Jung-Min;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.261-273
    • /
    • 2010
  • For the use of Indirect-conversion CMOS (complementary metal-oxide-semiconductor) detectors for digital x-ray radiography and their better designs, we have theoretically evaluated the spatial-frequency-dependent detective quantum efficiency (DQE) using the cascaded linear-systems transfer theory. In order to validate the developed model, the DQE was experimentally determined by the measured modulation-transfer function (MTF) and noise-power spectrum, and the estimated incident x-ray fluence under the mammography beam quality of W/Al. From the comparison between the theoretical and experimental DQEs, the overall tendencies were well agreed. Based on the developed model, we have investigated the DQEs values with respect to various design parameters of the CMOS x-ray detector such as phosphor quantum efficiency, Swank noise, photodiode quantum efficiency and the MTF of various scintillator screens. This theoretical approach is very useful tool for the understanding of the developed imaging systems as well as helpful for the better design or optimization for new development.

Soaking method & Particle In Binder method를 적용한 Photoconductor materials의 제작방식에 따른 X-ray Detector film 제작 및 전기적 특성평가

  • Lee, Yeong-Gyu;Yun, Min-Seok;Kim, Min-U;Kim, Yun-Seok;Jeong, Suk-Hui;Jeon, Seung-Pyo;Park, Geun-U;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.72-72
    • /
    • 2009
  • 본 연구에서는 Photoconductor materials 기반의 평판형 X-ray Detector film 제작에 관한 연구를 수행하였다. 기존의 광도전성 물질로 사용되어 오던 비정질 셀레늄(Amorphous seleinum; a-Se) 기반의 디지털 방사선 검출기 보다 높은 신호 및 동작 특성을 가지는 Mercury Iodide(HgI2)와 열적, 전기적 특성이 안정적이며, 소자의 동작특성이 우수한 Lead Oxide(PbO) 기반의 X-ray Detector film의 개발에 있어서 각각 HgI2 및 PbO 두 물질 층을 적정비율에 맞추어 제작함으로써 최적의 X-ray Detector를 구현하고자 하였다. 이는 빠른 영상획득을 통해 기존의 방식이 가지는 문제점을 해결하고 의료기기 디지털화를 구현할 수 있는 차세대 시스템을 개발하고자 하는 것이다. 본 연구에서는 기존의 진공증착법의 두꺼운 대면적 필름의 제조가 어려운 문제점을 해결하고자 Particle In Binder method(PIB) 방법을 이용하여 $3"{\times}3"$사이즈의 두께 $200{\mu}m$의 다결정의 Photoconductor 필름을 제조하여 전기적 특성을 평가하였다. 제작된 필름의 전기적 특성을 dark current, X-선 sensitivity와 SNR(Signal to -Noise Rate) 등을 측정하여 정량적으로 평가 하였다. 기준 실험으로 진행한 DG 2.1 바인더를 사용한 single-HgI2 층에서 보다 높은 sensitivity 값을 보였지만 높은 dark current로 인해 SNR이 떨어지는 결과를 볼 수 있었다. 본 연구에서 제시하는 두 Photoconductor material의 Soaking method를 이용한 실험에서는 single-HgI2에 해당하는 높은 sensitivity 및 저감된 dark current로 인해 높은 SNR 값을 획득하였다. 하지만 습도와 같은 주변 환경에 의한 재현성 문제로 인한 신호값의 불안정성에 대한 문제점도 남아 있으므로, 차후 최적화된 material 제작 공정을 위한 연구가 꾸준히 진행 되어져야 할 것이다.

  • PDF

Noise Reduction for Dual-energy X-ray Absorptiometry Image using Sparse Representation (Sparse 표현을 이용한 이중 에너지 X 선 흡수 영상 잡음 제거)

  • Kim, Hyungil;Eom, Wonyong;Kim, Dae Hoe;Ro, Yong Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.369-372
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위한 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도 영상은 이중 에너지 X 선 흡수법에 의해 측정되는데, 영상에 존재하는 잡음은 뼈 영역 추출과 골 밀도 계산에 어려움을 주고 있다. 따라서 본 논문에서는 최근 신호처리 분야에서 폭넓게 사용되고 있는 sparse 표현을 도입하여 X 선 영상의 잡음을 제거하는 방법을 제안한다. 실험을 통해 제안한 잡음 제거 방법의 결과가 기존의 방법에 비해 개선됨을 MSR(Mean to Standard deviation Ratio)과 CNR(Contrast to Noise Ratio)을 통해 확인하였다.

X-ray Arcelin Projection Study for Diagnosing Mastoid Process and Petrous Ports (꼭지돌기와 바위부 진단을 위한 엑스선 Arcelin 촬영법 연구)

  • Jun-Haeng Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.301-307
    • /
    • 2024
  • The Study Evaluated Radiography Images using the Mastoid Process Axial Oblique Projection (Arcelin) imaging method for the Diagnosis of Pyramid Ridge, Mastoid Process, Mastoid Process air cells, Tympanum, Internal auditory and petrous in Supine Position. The subjective ROC (receiver operation characteristic) evaluation method was conducted on five Radiological technologists who have worked in the Image medical Department of University Hospitals for more than 8 years, and the Objective Evaluation, signal-to-noise Ratio (SNR), was evaluated and Analyzed. The Cronbach Alpha value was significantly higher at 0.816. In the Image ROC Evaluation Taken by Tilting the X-ray Tube 5°, 10°, 15° toward the leg by 10°, it Scored 34 points, and in the overall evaluation, the SNR scored high at 6,549. In Addition, In the Image Evaluation taken by Tilting the X-ray Tube 5°, 10°, and 15° toward the head, it Scored 32 points In the Image ROC Evaluation taken by tilting 5°, and in the Objective Evaluation, SNR received the highest score of 6,732.

Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2015
  • We studied the compact anode design to develop 100 kW rotating anode X-ray tube with large focal spot 1.2 mm, small focal spot 0.6 mm and tube voltage 150 kV for large hospital digital radiography using computer thermal simulation. The larger thermal radiation effect in a high vacuum can reduce the temperature of anode so the method to increase the surface area of anode is investigated. The anode has the multi-tier shape at the back side of TZM body of anode and also bigger diameter of anode. The number of multi-tiers was varied from 6 to 15 and the diameter of anode was also varied from ${\Phi}74$ to ${\Phi}82$. From ANSYS transient thermal simulation result, we could obtain $1056.4^{\circ}C$ anode maximum temperature when applying 100 kW input power at 0.1 second on target focal track which is less than $1091^{\circ}C$ of the conventional 75 kW X-ray tube with reduced anode weight by 15.5% than the conventional anode. The compact anode of reduced anode weight is able to improve the unwanted noise when the rotor is rotating at high-speed and also reduce the rotational torque which the cost effective stator-coil is possible. It is believed that the anode with 15 ea multi-tiers using ${\Phi}82$ can satisfy with the specification of the anode heat capacity. From the results of this paper, it has been confirmed that the proposed compact anode can be used as the anode of 100 kW rotating anode X-ray tube for digital radiography.

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Noise Power Spectrum of Radiography Detectors: II. Measurement Based on the Spectrum Averaging (방사선 디텍터의 Noise Power Spectrum : II. Spectrum의 평균을 통한 측정)

  • Lee, Eunae;Kim, Dong Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.63-69
    • /
    • 2017
  • In order to observe the noise property of the flat-panel digital radiography detector, measuring the normalized noise power spectrum (NNPS) from acquired x-ray images is conducted. However, the conventional NNPS measurement has an unstable property depending on the acquired image. Averaging the sample periodograms of the input image is usually performed to estimate the NNPS values and increasing the number of samples can provide a reliable NNPS measurement. In this paper, for a finite number of images, two measurement methods, which are based on averaging spectra, such as the image periodogram, are proposed and their performances are analyzed. Using x-ray images acquired from two types of radiography detectors, the two spectrum averaging methods are compared and it is shown that averaging spectra based on the maximal number of combinations of the image pairs provides the best performance in measuring NNPS.

Nonuniform Gain Correction Based on the Filtered Gain Map in Radiography Image Detectors (방사선 영상 디텍터에서 필터링된 이득지도를 사용한 불균일 이득 잡음의 보정)

  • Kim, Dong Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.97-105
    • /
    • 2016
  • Radiography image detector produces digital images by collecting the charges from the incident x-ray photons and converting it to the voltage signals and then the digital signals. The fixed-pattern noise from the nonuinform amplifier gains in the employed multiple readout circuits. In order to correct the nonuniform gains, a gain-correction technique which is based on the gain map is conventionally used. Since the photon noise remains in the designed gain map, the noise contaminates the gain-corrected images. In this paper, experimental observations are conducted for filtering the remained noise in the gain map, and a filter optimization algorithm is proposed to efficiently remove the noise. For acquired x-ray images from detectors, the filtered gain maps are evaluated and it is shown that optimization algorithm can improve the filtering performance even for relatively strong fixed-pattern noises, which cannot be removed by a simple filter.

A Study on DC-DC Converter for X-Ray Using Soft-Switching Method (소프트 스위칭 방식을 이용한 X-Ray용 DC-DC Converter에 관한 연구)

  • Kim, Hack-Seong;Kim, Hyen-Joon;Won, Chung-Yuen;Yoo, Dong-Wook;Ha, Sung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.379-381
    • /
    • 1994
  • This paper is concerned with a zero-voltage soft-switching PWM DC-DC high-pelter converter using IGBTs, which Bakes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-Ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series resonant full-bridge PWM DC-DC high-Power converter operating at a constant frequency:20kHz. This technique brings about dramatic decreases in the switching losses of power devices and their electrical stresses as compared with the commonly-used hard-switching PWM DC-DC power converter. The high-frequency switching operation of the converters has some effective advantages, which consist in the physical reduction in size and weight and lowered acoustic noise.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.