• Title/Summary/Keyword: x-ray image

Search Result 1,278, Processing Time 0.048 seconds

Development of a soft X-ray microscopy system for Biological Application (생물의료용 연 X-선 현미경 시스템 개발)

  • Kim, Gyeong-U;Gwon, Yeong-Man;Kim, Gyu-Gyeom;Min, Jong-Hwan;Park, Jeong-Gwon;Im, Jong-Hyeok;Nam, Gi-Yong;Yun, Gwon-Ha;Min, Jin-Yeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.264-265
    • /
    • 2005
  • In this paper the conceptual design and development of a compact vertical type soft x-ray microscope is described. This x-ray microscope operates in the water window wavelength region(2.3 ${\sim}$ 4.4nm), where natural contrast between carbon(protein) and oxygen(water) allows imaging of unstained biological material their natural, hydrated environment. Until now, operational x-ray microscopes are based on synchrotron radiation sources, which limit their accessibility. Many biologists would benefit from having the x-ray microscope as a tool among other tools in their own laboratory, For this purpose we introduced the compact vertical type soft X-ray microscope with 50 nm resolution for biomedical application. The compact vertical type soft x-ray microscope is based on a laser plasma x-ray source, doubled ellipsoidal condenser reflective optics, diffractive zone plate optics and MCP coupled with CCD to record an x-ray image.

  • PDF

Development of the Imaging Optical System for the 545 nm Fluorescent Plate of X-ray (X선용 545 nm 형광판 결상광학계 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2008
  • To develop an imaging optical system for the 545 nm fluorescent plate of X-ray. Methods: We designed and manufactured a new imaging optical system for the 545 nm fluorescent plate of X-ray by Sigma 2000 program after deciding the design comparison standards referred to Canon CX2-70 model. Results: The characteristics of the new imaging optical system for the 545 nm fluorescent plate of X-ray have the magnification of -0.225x, the image field size of $90mm{\times}90mm$, and the 0.033 mm resolution line width at the 30% MTF value criterion. These mean that the new model has a capability of deciphering for the more large screen and the resolution of deciphering is superior to that of Canon CX2-70 model. Also the image side NA (-0.196) of the new model is about $\sqrt{2}$ times than that (-0.139) of CX2-70 and the object side NA (0.044) of the new model is about 2 times than that (0.022) of CX2-70. These mean that the sensitivity of the film in the new design model is able to be increased to about 4 times and there is the possibility of reducing the bombed time of X-ray to 1/4 times. Conclusions: We could design and manufacture the imaging optical system for the 545 nm fluorescent plate of X-ray having the possibility of reducing the bombed time of X-ray to 1/4 times in comparision to Canon CX2-70 model, the characteristics of which have the image field size of $90mm{\times}90mm$ and the MTF of 30% or more at 15 lines/mm criterion.

  • PDF

Evaluation of Usefulness of Assertive Devices to Improve the Accuracy in Skull lateral X-ray Projection (두개골 측방향 X-선 촬영에서 정확도 향상을 위한 촬영 보조 기구의 유용성 평가)

  • Bo-Seok Chang
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2024
  • In X-ray projection, Unskilled radiologists become skilled through fail exam. This causes the patient to be exposed to unnecessary radiation. In this study, pre-position unskilled radiologic technologist presented ways to improve clinical proficiency. presented a skull lateral x-ray projection practice method using visual, spatial, and assistive devices. In addition, the accuracy and usefulness of the use of assistive devices were evaluated. When X-ray images were taken based on learning, the rotational spacing, which indicates image distortion, was 7.85 ± 1.45 mm and the tiliting spacing was 4.84 ± 0.5 mm. When practicing using visual aids, the rotational spacing is 4.4 ± 0.76 mm and the inclination spacing is 3.01 ± 0.87 mm. using a spatial compensation device, the rotational spacing is 5.2 ± 0.69 mm and the tiliting spacing is 3.33 ± 0.61 mm. Skull lateral X-ray Image distortion caused by empirical photography practice decreased by 5.4%, but image distortion caused by tilting increased by 1.2%. When practicing using a visual assistive devices, the degree of rotational spacing by 40.1% and the tiliting spacing decreased by 30.7% compared to the empirical x-ray exposure practice. When using spatial assistive devices, the rotation interval was reduced by 41.7% and the tilting interval by 23.7% compared to conventional empirical x-ray exposure practice. Therefore, if an unskilled radiologist practices using visual and spatial aids,the accuracy will be improved in skull lateral x-ray projection.

A Tuberculosis Detection Method Using Attention and Sparse R-CNN

  • Xu, Xuebin;Zhang, Jiada;Cheng, Xiaorui;Lu, Longbin;Zhao, Yuqing;Xu, Zongyu;Gu, Zhuangzhuang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2131-2153
    • /
    • 2022
  • To achieve accurate detection of tuberculosis (TB) areas in chest radiographs, we design a chest X-ray TB area detection algorithm. The algorithm consists of two stages: the chest X-ray TB classification network (CXTCNet) and the chest X-ray TB area detection network (CXTDNet). CXTCNet is used to judge the presence or absence of TB areas in chest X-ray images, thereby excluding the influence of other lung diseases on the detection of TB areas. It can reduce false positives in the detection network and improve the accuracy of detection results. In CXTCNet, we propose a channel attention mechanism (CAM) module and combine it with DenseNet. This module enables the network to learn more spatial and channel features information about chest X-ray images, thereby improving network performance. CXTDNet is a design based on a sparse object detection algorithm (Sparse R-CNN). A group of fixed learnable proposal boxes and learnable proposal features are using for classification and location. The predictions of the algorithm are output directly without non-maximal suppression post-processing. Furthermore, we use CLAHE to reduce image noise and improve image quality for data preprocessing. Experiments on dataset TBX11K show that the accuracy of the proposed CXTCNet is up to 99.10%, which is better than most current TB classification algorithms. Finally, our proposed chest X-ray TB detection algorithm could achieve AP of 45.35% and AP50 of 74.20%. We also establish a chest X-ray TB dataset with 304 sheets. And experiments on this dataset showed that the accuracy of the diagnosis was comparable to that of radiologists. We hope that our proposed algorithm and established dataset will advance the field of TB detection.

Restoration of Chest X-ray Image Using Dual Projection Filter (이중 프로젝션 필터를 이용한 흉부 X-선 영상의 복원)

  • 이태수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 1992
  • A new restoration method of chest X -ray image (dual project filter) was proposed to improve SNR(signal to noise ratio) characteristics. In this method, a priori Information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lung region, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

A Study about Reduction Method of the X-Ray Film Image (X선 사진의 감력법에 대한 실험 고찰)

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.55-55
    • /
    • 1991
  • I reduced overexposed X-Ray film image with farmer reduction method and $KMnO_4$ reduction method. The results are as follows : 1. In farmer reduction method, there appears linear decreasing film image density. 2. In $KMnO_4$ reduction method, there appears over proportional reduction. 3. When red prussiate is compared with $KMnO_4$ reduction method, the latter shows more intense reduction. 4. If the reduction solution isn't used within 10 minutes after dilution, it becomes oxidized and the ability is decreased remarkably.

  • PDF

Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application (레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계)

  • 김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

The Diagnosis of Rheumatologic and Degenerative Arthritis by X-ray Sacroiliac Joint Projection (X-ray 엉치엉덩관절 촬영법을 통한 류마티스 및 퇴행성관절염 진단)

  • Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.397-402
    • /
    • 2018
  • The study best image for diagnosis of fracture, dislocation and unilateral degenerative arthritis of the Sacroiliac joint, this study was performed to obtain the best image of the joint space of the hip joint by giving angle change to the pelvis phantom and the x-ray tube. I received evaluation. The results of the Receiver Operating Characteristic that in the case of simple photographs for the detection of joint arthritis and degenerative arthritis in the prone position, the photograph taken in the prone position raises the buttocks of the opposite side of the test by $25^{\circ}{\sim}30^{\circ}$ and the x-ray tube is perpendicular to the sagittal plane passing 2.5 cm inward from the thorny vertebra In the lying position, lift the Sacroiliac joint of the test side by $25^{\circ}{\sim}30^{\circ}$, and take a $5^{\circ}$ angle of the x-ray tube angle toward the foot toward the center of the upper bruch spine from it will be helpful to diagnose arthritis. the center of the upper bruch spine to the side of the ankle joints in the transverse direction And posterior direction, it will be helpful to diagnose arthritis.

Distribution of the Scatter Ray on Chest X-ray Examinations (흉부 X선 촬영 시 산란선 분포 연구)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.255-260
    • /
    • 2012
  • This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist's entrance door, and the opening of the radiological technologist's entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.