• 제목/요약/키워드: x-ray cross-sectional image

검색결과 38건 처리시간 0.027초

습식 표면개질 처리된 폴리이미드 필름 표면의 특성에 관한 연구 (A Study on Characteristics of Surface Modified Polyimide Film by Wet Process)

  • 구석본;이홍기
    • 한국표면공학회지
    • /
    • 제39권4호
    • /
    • pp.166-172
    • /
    • 2006
  • Metallized Polyimide films are extensively used as base materials in microelectronics, optical and automotive applications. However it is difficult to deposit metals on those because of their structural stabilities. In this work, polyimide films are modified by a wet process with alkalinemetalhydroxide and additives to introduce functional groups. The surface molecular structures of polyimide are investigated using X-ray photoelectron spectroscopy(XPS), fourier transform infrared reflection spectroscopy(FTIR-ATR), atomic force micro-scopic(AFM). XPS spectra and FTIR spectra show that the surface structure of polyimide is converted into potassium polyamate. AFM image and AFM cross-sectional analyses reveal the increased roughness on the modified surface of polyimide films. As a result, it is shown that the adhesion strength between polyimide surface and electroless nickel layer is increased by the nano-anchoring effect.

딥러닝 기반 균열 추출 기법을 통한 수압 파쇄 균열 형상 분석 (Morphological Analysis of Hydraulically Stimulated Fractures by Deep-Learning Segmentation Method)

  • 박지민;김광염;윤태섭
    • 한국지반공학회논문집
    • /
    • 제39권8호
    • /
    • pp.17-28
    • /
    • 2023
  • 본 연구에서는 화강암 시편을 대상으로 파쇄 유체의 점성과 주입 속도를 변화시키며 실내 수압 파쇄 실험을 수행하였고, 3D X-ray CT 촬영을 통해 파쇄 후 시편 내부를 관찰하였다. 이미지 처리에 탁월한 성능을 보이는 합성곱 신경망(Convolutional Neural Network, CNN) 기반 Nested U-Net 모델 구조를 활용하여 CT 이미지 내 수압 파쇄 균열 추출을 수행하였고, 복잡한 형상의 미세균열을 정교하게 추출할 수 있었다. CNN 기반 모델로 추출된 균열을 3차원으로 재구성하여 균열의 부피, 두께, 굴곡도, 균열면 거칠기를 분석하였다. 그 결과 파쇄 유체의 점성이 클수록 균열 부피와 두께가 증가하였고, 굴곡도와 균열면의 거칠기가 감소하는 경향을 보였다. 또한 균열면의 굴곡도와 거칠기 이방성이 존재함을 확인할 수 있었다. 본 연구는, CNN 기반의 균열 추출 모델을 활용해 전통적인 이미지 처리 방법보다 정교한 균열 추출을 수행하고, 이를 기반으로 수압 파쇄 균열의 정량 분석을 성공적으로 수행하였다.

한국인 척추 연구를 위한 형상 / 물성 정보 구축 (Geometry and Property Database for Korean Spine Research)

  • 이승복;이상호;한승호;곽대순
    • 한국콘텐츠학회논문지
    • /
    • 제11권10호
    • /
    • pp.488-493
    • /
    • 2011
  • 한국과학기술정보연구원과 가톨릭대학교 의과대학 가톨릭응용해부연구소에서는 척추 연구자들이 쉽게 사용할 수 있는 기초 자료를 구축하고 있다. 척추 형상 정보를 제공하기 위해 60-80대 기증시신 20여 표본을 활용하여 고해상도 척추 (whole spine) CT (pixel dimension : 0.4x mm, thickness: 0.6mm)를 촬영하고 이를 3차원 모델링 소프트웨어(Mimics, Ver.14, Materialise, Belgium)를 사용하여 3차원 형상 모델(shell model, STL format)로 구축하고, 목, 등, 허리 척추의 주요 부위를 계측하여 수치화 하였다. 시신기반 자료의 한계를 극복하기 위해 고령자 호발 질환을 중심으로 대상 환자를 선정하여 X-Ray, CT, BMD 자료를 구축하여 보강하고 있다. 물리적 성질 정보 구축은 기증시신 10여 표본을 활용하여 임상적, 물리적 골밀도를 측정하고, 목척추(cervical), 등척추(thoracic), 허리척추(lumbar) 부분의 굽힘-폄(flexion-extension), 가쪽 굽힘(lateral bending), 회전(torsion), 압축(body/disc compression) 시험을 수행하여 작용력과 굽힘량의 관계를 구축하고 있다. 구축된 물성 시험 결과는 형상 모델과 함께 제공되어 자료의 활용도를 높이고 있으며, 이를 이용하여 한국인 특성이 반영된 척추 관련 연구 및 제품 개발에 활용 될 수 있다.

방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교 (A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography)

  • 고혜숙;유현미;박동성
    • Restorative Dentistry and Endodontics
    • /
    • 제32권1호
    • /
    • pp.61-68
    • /
    • 2007
  • 이 연구의 목적은 네 종류 file systems의 중심유지능과 근관성형 전후의 상아질 삭제량을 비교하는 것이다. 10-20도의 만곡을 갖는 발거된 20개의 하악 제1대구치의 근심근관(총 40개의 근관)을 근관성형 전에 X선 미세단층촬영 스캐너를 이용하여 스캔하였다. 제 1군은 근관부를 넓힌 후 stainless steel K-Flexofile을 사용하여 step-back technique으로 근관성형하였고, 나머지 군들은 각 제조사의 추천대로 ProFile system (2군), ProTaper system (3군), K3 system (4군)을 사용하여 crown-down technique으로 근관성형하였다. 모든 근관의 근단부 기구조작은 #25 크기까지 시행하였고 근관성형 후 스캔하였다. 3차원 영상 소프트웨어로 근관성형 전후의 스캔된 이미지들을 재구성하여 근관의 전체적 부피 변화를 측정하였다. 또한, 근단공으로부티 1, 3, 5, 7 mm되는 지점의 근관 횡단면을 비교하여 근관성형 전후의 단면적 변화와 중심변위율을 산출하였다. 그 결과, ProTaper와 K3가 다른 file systems보다 상아질을 더 많이 삭제하는 경향을 보였고 모든 실험군에서 중심 변위율은 근단공으로부터 3 mm 지점에서 가장 낮은 수치를 나타냈으며, 3 mm 지점을 제외하고는 ProTaper가 다른 file systems보다 중심유지능이 떨어지는 결과를 얻을 수 있었다 (P < 0.05).

Indium 첨가된 SnO2 후막형 가스센서의 특성 (Characteristics of Indium Doped SnO2 Thick Film for Gas Sensors)

  • 유일;이지영
    • 한국재료학회지
    • /
    • 제20권8호
    • /
    • pp.408-411
    • /
    • 2010
  • Indium doped $SnO_2$ thick films for gas sensors were fabricated by a screen printing method on alumina substrates. The effects of indium concentration on the structural and morphological properties of the $SnO_2$ were investigated by X-ray diffraction and Scanning Electron Microscope. The structural properties of the $SnO_2$:In by X-ray diffraction showed a (110) dominant $SnO_2$ peak. The size of $SnO_2$ particles ranged from 0.05 to $0.1\;{\mu}m$, and $SnO_2$ particles were found to contain many pores, according to the SEM analysis. The thickness of the indium-doped $SnO_2$ thick films for gas sensors was about $20\;{\mu}m$, as confirmed by cross sectional SEM image. Sensitivity of the $SnO_2$:In gas sensor to 2000 ppm of $CO_2$ gas and 50 ppm of H2S gas was investigated for various indium concentrations. The highest sensitivity to $CO_2$ gas and H2S gas of the indium-doped $SnO_2$ thick films was observed at the 8 wt% and 4 wt% indium concentration, respectively. The good sensing performances of indium-doped $SnO_2$ gas sensors to $CO_2$ gas were attributed to the increase of oxygen vacancies and surface area in the $SnO_2$:In. The $SnO_2$:In gas sensors showed good selectivity to $CO_2$ gas.

나선형 단층방사선사진촬영에서 촬영조건이 악골 단면상의 높이, 폭 및 인지도에 미치는 영향 (The effect of different radiographic parameters on the height, width and visibility of cross-sectional image of mandible in spiral tomography)

  • 이태완;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.43-49
    • /
    • 2003
  • Purpose : To evaluate the differences in bone height, bone width, and visibility of posterior spiral tomographic images according to various exposure directions, image layer thickness, and inclination of the mandibular inferior border. Materials and Methods: Six partially and completely edentulous dry mandibles were radiographed using Scanora spiral tomography. Spiral tomography was performed at different exposure directions (dentotangential and maxillotangential projection), image layer thicknesses (2 mm, 4 mm and 8 mm), and at various inclinations to the mandibular border (+ 100, 00 and -10°). The bone height and width was measured using selected tomographic images. The visibility of mandibular canal, crestal bone, and buccal and lingual surfaces were graded as 0, 1, or 2. Results : The bone width at the maxillo-tangential projection was wider than at the dento-tangential projection (p < 0.05). The visibility of buccal and lingual surface at the maxillo-tangential projection was higher than at the dento-tangential projection (p<0.05). Thinner image layer thicknesses resulted in greater visibility of buccal and lingual surfaces (p < 0.05). Bone height was greatest in the -10° group, and at the same time the bone width of the same group was the narrowest (p < 0.05). The visibility of alveolar crest and buccal surface of the + 10° group was the highest, while the visibility of the mandibular canal was greatest in the 00 group. Conclusion: When spiral tomography is performed at the mandibular posterior portion for visualization prior to implant surgery, it is important that the inferior border of mandible be positioned as parallel as possible to the floor. A greater improvement of visibility can be achieved by maintaining a thin image layer thickness when performing spiral tomography.

  • PDF

나노급 Au층 삽입 니켈실리사이드의 미세구조 변화 (Microstructure Evaluation of Nano-thick Au-inserted Nickel Silicides)

  • 윤기정;송오성
    • 한국재료학회지
    • /
    • 제18권1호
    • /
    • pp.5-11
    • /
    • 2008
  • Thermally evaporated 10 nm-Ni/1 nm-Au/(30 nm-poly)Si structures were fabricated in order to investigate the thermal stability of Au-inserted nickel silicide. The silicide samples underwent rapid thermal annealing at $300{\sim}1100^{\circ}C$ for 40 seconds. The sheet resistance was measured using a four-point probe. A scanning electron microscope and a transmission electron microscope were used to determine the cross-sectional structure and surface image. High-resolution X-ray diffraction and a scanning probe microscope were employed for the phase and surface roughness. According to sheet resistance and XRD analyses, nickel silicide with Au had no effect on widening the NiSi stabilization temperature region. Au-inserted nickel silicide on a single crystal silicon substrate showed nano-dots due to the preferred growth and a self-arranged agglomerate nano phase due to agglomeration. It was possible to tune the characteristic size of the agglomerate phase with silicidation temperatures. The nano-thick Au-insertion was shown to lead to self-arranged microstructures of nickel silicide.

Back-Projection을 활용한 홍삼 내부 측정 시스템 (A Red Ginseng Internal Measurement System Using Back-Projection)

  • 박재영;이상준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제7권10호
    • /
    • pp.377-382
    • /
    • 2018
  • 본 연구는 홍삼 등급 판정을 위한 내부 상태 및 조직의 치밀도 분석 방법에 관한 것이다. 홍삼 내부 측정을 위해 1990년대 이후부터는 자기공명영상법(MRI), X-ray 판별 등의 비파괴 검사 방법에 대한 연구가 다양하게 이루어졌지만, 등급 판정에 가장 중요한 내공(內空), 내백(內白)을 파악하는데 어려움이 있어 정확한 내부 판정이 불가능하였다. 그리하여 본 연구에서는 적외선 조명 환경의 폐쇄형 영상 취득 장치를 제작하고 내공, 내백의 유무와 직경을 파악할 수 있는 내부 측정 시스템을 개발하였다. 제작한 장치는 홍삼 내부 투과율이 높은 950nm 파장대역의 적외선 조명, 적외선 대역 촬영이 가능한 카메라, 카메라에 홍삼의 초점을 자동제어 할 수 있는 Y축 제어 액추에이터 그리고 홍삼을 $1^{\circ}$의 간격으로 $360^{\circ}$ 회전하며 영상을 취득할 수 있는 회전 액추에이터로 구성이 되어있다. 제안하는 알고리즘은 Y축 액추에이터에서 Auto-Focus 알고리즘을 수행하여 홍삼의 크기와 두께 변화에 따라 객체의 선명한 초점을 자동으로 맞춰준다. 그다음 홍삼을 $1^{\circ}$ 간격으로 $360^{\circ}$ 회전하며 총 360장의 홍삼 영상을 취득하면 라돈 변환(Radon transform)을 통해 사이노그램(Sinogram)으로 재구성하고, 역 라돈 변환(Inverse Radon transform)을 통해 단층영상복원(Back-projection) 알고리즘이 수행되어 홍삼 내부 영상을 획득하였다. 알고리즘 수행 결과 홍삼 두께나 모양에 관계없이 내부 단면영상 획득이 가능하였고 영상을 통해 내공, 내백의 유무와 직경을 파악할 수 있었다. 추후 10,000개 이상의 다양한 모양과 크기를 가지는 홍삼에 대하여 내부 영상을 취득하여 등급 판별 기준을 적용한다면 신뢰성 있는 홍삼 등급 자동화 측정 방법으로 사용가능 할 것이다.

Development of an evidence-based clinical imaging diagnostic guideline for implant planning: Joint recommendations of the Korean Academy of Oral and Maxillofacial Radiology and National Evidence-based Healthcare Collaborating Agency

  • Kim, Min-Ji;Lee, Sam-Sun;Choi, Miyoung;Ha, Eun Ju;Lee, Chena;Kim, Jo-Eun;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.45-52
    • /
    • 2020
  • Purpose: This study was conducted to develop an evidence-based clinical imaging diagnostic guideline for implant planning, taking into account efficacy, benefits, and risks. Materials and Methods: The guideline development process employed the adaptation methodology used for Korean clinical imaging guidelines(K-CIG). Core databases(Ovid-Medline, Ovid-Embase, National Guideline Clearinghouse, Guideline International Network) and domestic databases (KoreaMed, KMbase, and KoMGI) were searched for guidelines. The retrieved articles were analyzed by 2 reviewers, and articles were selected using well-established inclusion criteria. Results: The search identified 294 articles, of which 3 were selected as relevant guidelines. Based on those 3 guidelines, 3 recommendations for implant planning were derived. Conclusion: We recommend radiography or cone-beam computed tomography (CBCT) scanning for individual patients judged to require a cross-sectional image after reading of a panoramic X-ray image and a conventional intraoral radiological image. Various steps should be taken to raise awareness of these recommendations among clinicians and the public, and K-CIG should be regularly reviewed and revised.

$Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ 구조의 전기적 특성 분석 및 $SrTiO_3$박막의 완충층 역할에 관한 연구 (Electrical Properties in $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ Structure and the Role of $SrTiO_3$ Film as a Buffer Layer)

  • 김형찬;신동석;최인훈
    • 한국전기전자재료학회논문지
    • /
    • 제11권6호
    • /
    • pp.436-441
    • /
    • 1998
  • $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ structure was prepared by rf-magnetron sputtering method for use in nondestructive read out ferroelectric RAM(NDRO-FEAM). PBx(Zr_{0.52}Ti_{0.48})O_3}$(PZT) and $SrTiO_3$(STO) films were deposited respectively at the temperatures of $300^{\circ}C and 500^{\circ}C$on p-Si(100) substrate. The role of the STO film as a buffer layer between the PZT film and the Si substrate was studied using X-ray diffraction (XRD), Auger electron spectroscopy (ASE), and scanning electron microscope(SEM). Structural analysis on the interfaces was carried out using a cross sectional transmission electron microscope(TEM). For PZT/Si structure, mostly Pb deficient pyrochlore phase was formed due to the serious diffusion of Pb into the Si substrate. On the other hand, for STO/PZT/STO/Si structure, the PZT film had perovskite phase and larger grain size with a little Pb interdiffusion. the interfaces of the PZT and the STO film, of the STO film and the interface layer and $SiO_2$, and of the $SiO_2$ and the Si substate had a good flatness. Across sectional TEM image showed the existence of an amorphous layer and $SiO_2$ with 7nm thickness between the STO film and the Si substrate. The electrical properties of MIFIS structure was characterized by C-V and I-V measurements. By 1MHz C-V characteristics Pt/STO(25nm)/PZT(160nm)/STO(25nm)/Si structure, memory window was about 1.2 V for and applied voltage of 5 V. Memory window increased by increasing the applied voltage and maximum voltage of memory window was 2 V for V applied. Memory window decreased by decreasing PZT film thickness to 110nm. Typical leakage current was abour $10{-8}$ A/cm for an applied voltage of 5 V.

  • PDF