• 제목/요약/키워드: x-radiation

검색결과 2,094건 처리시간 0.032초

수침 문화재 보존 처리에 있어 엑스선 조사의 연속성에 따른 살균력 효과 비교 (Comparison of the Effectiveness of Disinfection According to the Permanence of X-ray Irradiation for Preservation of Water-logged Cultural Heritages)

  • 조경서;곽영혁;이면주;정래동;박해준
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.533-542
    • /
    • 2023
  • We developed an emergency national manual for preservation of cultural heritage using irradiation disinfection technic under flood disaster. And we examined its practicality with a critical radiation dose on fungi that occur at water-logged event in order to prevent fungal damage that occurs during submersion. The X-ray irradiation for this experiment was conducted at the Production Technology Research Institute located in Yeongcheon, Gyeongsangbuk-do. A disinfection critical dose of 12 kGy was selected for two types of fungi known to spread rapidly and are resistant to radiation to submerged cultural properties, and this experiments were conducted by setting a target dose of 12kGy at 8.37mA at 5MeV. Under the above conditions, only continuity of irradiated samples were completely disinfected. This suggests that continuity of irradiation is important for fungal disinfection.

교정용 단일에너지 형광 X-선장의 제작 (Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields)

  • 김장렬;김봉환;장시영;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제23권1호
    • /
    • pp.33-47
    • /
    • 1998
  • 한국원자력연구소 교정시설에 설치되어 있는 MG325 X-선 발생장치와 ISO-4037에서 제시하고 있는 라디에이티 및 필터 8종을 조합하여 8.6 keV 부터 75 keV 까지의 단일에너지 형광 X-선을 제작하였다. 1차 X-선에 의하여 라디에이터에서 발생된 형광 X-선중 $K_{\beta}$를 필터를 사용하여 제거한 후 단지 $K_{\alpha}$만의 형광 X-선 스펙트럼을 고순도 평판형 반도체검출기와 휴대용 다중파고분석기로 분석하였으며 35 cc 전리함을 이용하여 이때의 선량률 (air kerma rates)를 측정하여 계산결과와 비교하였다. 또한 방사선장의 균일도분포를 전리함과 사진현상을 통하여 결정하였으며 산란 X-선의 영향도 측정하여 실제 적용가능성을 검토하였다. 실험결과 순도가 90 % 이상되는 8.6 keV부터 75 keV까지의 단일에너지 형광 X-선을 얻었으며 라디에이터 중심으로부터 43 cm 위치에서의 선량률은 1.91 mGy/h (라디에이터 : Au, 필터 : W)로부터 54.2mGy(라디에이터 : Mo, 필터 : Zr) 까지였다. 선량률 측정지점에서 방사선장의 유효면적은 12 cm ${\times}$ 12 cm로 계측기의 교정이나 개인선량계의 조사에 전혀 문제가 없음을 확인하였고 산란방사선의 영향도 3% 이하였다.

  • PDF

COVID 19 유행에 따른 컨테이너를 이용한 선별 X-선 검사실의 안전성에 대한 고찰 (A Study on the Safety of a Screening X-ray Laboratory Using Containers in accordance with the COVID 19 Outbreak)

  • 김재석
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.425-431
    • /
    • 2020
  • COVID-19로 인해 수출용 컨테이너에 방사선 발생 장치를 설치한 경우 방사선실의 공간선량을 측정하고 검사실 내의 차폐벽의 효용성에 대하여 연구하고자 하였다. 측정 지점은 X-선관에서 검사자가 있는 뒤쪽으로 이동식 차폐벽을 사용하지 않았을 때를 12곳을 측정하였으며, 이와 대조군으로 이동식 차폐벽을 사용한 후 차폐벽 뒤에서 3곳을 측정하였다. 측정은 Survey Meter를 켜고 배후 방사선(Background)을 측정하였고, 배후 방사선(Background)에서 측정 Peak치 값을 빼서 산출하였다. 이동식 차폐벽 없이 X-선관 뒤, 50cm, 100cm, 200cm로 설정하여 12 곳을 측정하였고, 이동식 방사선 차폐벽을 사용하여 X-선관 뒤에서 3곳을 측정하여 이동식 방사선 차폐벽의 사용 전후의 선량값을 비교하였다. 이동식 차폐벽의 사용 여부에 따라 측정된 선량의 평균값을 대응표본 t 검정을 통하여 결과값 p < 0.05(양측)로 검증하였다. 측정값은 X-선관 뒤 좌측 50cm : 1.446μSv, X-선관 뒤 : 0.545μSv, X-선관 뒤 우측 50cm : 1.466μSv, 방사선 방어용 벽 뒤에서 측정값은 0.190μSv, 0.204μSv, 0.191μSv였다. 실측한 결과 검사실 내에서의 차폐벽으로 인한 검사자의 의료 피폭은 82.3%로 감소시킬 수 있었다. 선별 방사선 검사실에서의 직업 피폭을 감소시키기 위해서는 방사선 발생원으로부터 충분한 이격과 차폐벽의 사용을 권고하는 바이다.

Mechanical properties and radiation shielding performance in concrete with electric arc furnace oxidizing slag aggregate

  • Lim, Hee Seob;Lee, Han Seung;Kwon, Seung Jun
    • Journal of Ceramic Processing Research
    • /
    • 제20권4호
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, physical properties of normal concrete, magnetite concrete, EAF concrete, and EAF concrete with added iron powder were evaluated and a feasibility of radiation shielding is also evaluated through irradiation tests against X-rays and gamma-rays. While the unit weight of EAF concrete (3.21 t/㎥) appeared lower than that of magnetite concrete (3.50 t/㎥), the results in compressive strength of EAF concrete were greater than those in magnetite and normal concrete. While the radiation transmission rate of normal concrete reaches 26.0% in the X-ray irradiation test, only 6.0% and 9.0% of transmission rate were observed in magnetite concrete and linear relationship with unit volume weight and radiation shielding. In the gamma-ray irradiation test, the performance of EAF and magnetite concretes appeared to be similar. Through the results on the excellent physical properties and radiation shielding performance a potential applicability of EAF concrete to radiation shielding was verified.

Removal of NOx using electron beam process with NaOH spraying

  • Shin, Jae Kyeong;Jo, Sang-Hee;Kim, Tae-Hun;Oh, Yong-Hwan;Yu, Seungho;Son, Youn-Suk;Kim, Tak-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.486-492
    • /
    • 2022
  • Nitrogen oxides (NOx; NO and NO2) are major air pollutants and can cause harmful effects on the human body. Electron Beam Flue Gas Treatment (EBFGT) is a technology that generates electrons with an energy of 0.5-1 MeV using electron accelerators and effectively processes exhaust gases. In this study, NOx was removed using an electron beam accelerator with spraying additives (NaOH and NH4OH). NO and NO2 were 100% and more than 94% removed, respectively, at an electron beam absorbed dose of 20 kGy and an additive concentration of 0.02 M (mol/L). In most cases, NOx was removed better with lower initial NOx concentrations and higher electron beam absorbed doses. As the irradiation strength (mA) of the electron beam increases, the probability of electron impact on the material accordingly rises, which may lead to increase removal efficiency. The results of the present study show that the continuous electron beam process using additives achieved more effective removal efficiency than either individual process (wet-scrubbing or EB irradiation only).

사이버나이프에서 폐종양 추적 시스템의 정확도 분석 (Verification of X-sight Lung Tracking System in the CyberKnife)

  • 허현도;최상현;김우철;김헌정;김성훈;조삼주;민철기;조광환;이상훈;최진호;임상욱;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제20권3호
    • /
    • pp.174-179
    • /
    • 2009
  • 사이버나이프 로봇 방사선 수술 시스템은 환자를 치료하는 동안 환자의 내부 기준 마커를 이용하여 종양의 위치를 실시간으로 추적 할 수 있는 시스템이다. 최근 폐종양 치료의 경우 기준 마커의 삽입 없이 폐종양의 밀도 차이를 이용하여 실시간 종양 추적을 할 수 있는 폐종양추적시스템이 개발되어 치료에 적용되고 있다. 최근 개발되어 국내 최초 도입된 폐종양 추적치료시스템의 위치 추적 정확도의 분석은 동적흉부 팬톰과 GafChromic film을 이용하였다. 폐종양추적시스템을 이용하여 종양의 위치 추적 정확도는 평균 오차 $0.85{\pm}0.22$ mm로 분석되었다. 기준마커 삽입 없이 폐종양추적시스템을 이용하여 폐종양 치료에 매우 유용한 것으로 판단되었다.

  • PDF

앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구 (A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.189-193
    • /
    • 2011
  • 상지 검사(upper extremity X-ray examinations, UEX) 시 환자 위치 잡이로 가장 많이 활용되고 있는 앉은 자세 상지 X-ray 검사(sitting position upper extremity X-ray examinations, SUEX) 시 방사선에 민감한 생식샘과 목적장기 이외 부위에 대한 피폭이 크다고 판단되어 의료기관 별 SUEX 시 납 앞치마(Apron) 착용 유무와 생식샘 및 목적장기 이외 부위에 대한 방사선 피폭과 피폭선량 감소 방안에 대한 연구 결과 거리가 멀어 질수록, 조사야 조절장치를 가능한 목적장기 부위로 제한 조절할수록, 피사체의 두께가 얇을수록 방사선에 의한 피폭은 감소하였고, 생식샘 차폐 유무에 따른 피폭은 생식샘을 차폐했을 때 약 10~50%의 저감화효과를 얻을 수 있었다. 또한 검사 시 apron 착용 유무에 대한 조사에서는 대부분의 경우 apron을 착용하지 않은 것으로 조사되어 시급히 시정되어야 될 것으로 생각된다.

Comparison Study on Changes of Antigenicities of Egg Ovalbumin Irradiated by Electron Beam or X-Ray

  • Kim, Mi-Jung;Lee, Ju-Woon;Sung, Nak-Yoon;Kim, Su-Min;Hwang, Young-Jung;Kim, Jae-Hun;Song, Beom-Seok
    • 한국축산식품학회지
    • /
    • 제34권5호
    • /
    • pp.570-575
    • /
    • 2014
  • This study was conducted to compare the effects of two forms of radiation (electron and X-ray; generated by an electron beam accelerator) on the conformation and antigenic properties of hen's egg albumin, ovalbumin (OVA), which was used as a model protein. OVA solutions (2.0 mg/mL) were individually irradiated by electron beam or X-ray at the absorbed doses of 0 (control), 2, 4, 6, 8, and 10 kGy. No differences between the two forms of radiation on the structural properties of OVA were shown by spectrometric and electrophoretic analyses. The turbidity of OVA solution increased and the main OVA bands on polyacrylamide gels disappeared after irradiation, regardless of the radiation source. In competitive indirect enzyme-linked immunosorbent assay, OVA samples irradiated by electron beam or X-ray showed different immunological responses in reactions with monoclonal and polyclonal antibodies (immunoglobulin G) produced against non-irradiated OVA. The results indicate that electron beam irradiation and X-ray irradiation produced different patterns of structural changes to the OVA molecule.

단일에너지 형광 X선 및 연속 스펙트럼 X선장에 의한 TLD 알고리즘 개발 (Development of TLD Algorithms by Monochromatic Fluorescence Radiations and Continuous Spectrum X-rays)

  • 김장렬;김봉환;장시영;이계기
    • Journal of Radiation Protection and Research
    • /
    • 제23권3호
    • /
    • pp.159-174
    • /
    • 1998
  • 개인방사선측정시스템은 광범위한 에너지의 방사선에 대하여 정확한 개인선량당량을 측정할 수 있어야 하지만 현재 사용중인 선량평가 알고리즘은 ANSI N13.11의 방사선장과 거의 유사한 과학기술부 고시에 명시되어 있는 X-선장을 기준으로 개발되었고 이는 실제 측정이 요구되는 방사선장과 상당한 차이가 있을 수 있다. 방사선작업종사자가 ANSI N13.11의 방사선장과 다른 형태의 방사선에 피폭되었을 경우 좀더 정확한 선량을 평가하기 위하여 한국원자력연구소에 설치되어 있는 단일에너지 X-선장에 $CaSO_4:Dy$ 열형광체를 조사시켜 에너지반응도를 실험적으로 구한 후 두 가지 형태의 알고리즘을 개발하였으며 이를 ANSI N13.11의 연속스펙트럼 X-선장에 기본을 두고 개발한 알고리즘과 비교하였다. 알고리즘 개발 후 ANSI, ISO의 연속 스펙트럼 X-선 및 단일에너지 X-선장과 IAEA/RCA 상호비교시험시 사용되었던 혼합방사선장 및 각도변화 실험데이타를 이용하여 이를 검증하였다. 검증결과 개발된 알고리즘들은 과학기술부 고시에 나타나 있는 X-선장뿐만 아니라 방사선작업환경에서 피폭될 수 있는 다른 종류의 방사선장에서도 매우 정확한 선량평가를 하고 있음을 확인하였다.

  • PDF