• Title/Summary/Keyword: x-MR분석

Search Result 41, Processing Time 0.033 seconds

Analysis of Actual Cross-Sectional Area During Scanning According to MRI Bore Size (MRI 보어 구경에 따른 검사 시 실효 단면적 분석)

  • Jeong, Hyunkeun;Jeong, Hyundo;Kim, Seongho;Jeon, Mincheol;Yoo, Sejong;Ko, Hyuncheol;Cho, Yonghyun
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.219-227
    • /
    • 2020
  • In this study, we tried to quantify the actual cross-sectional area inside the bore when scanning by the MRI system with various bore sizes. To this end, a comparative analysis was conducted by both of blueprint of each MRI equipment and actual measurement in the field. As a result of analysis, ACSA(Actual Cross-Sectional Area) in Ingenia CX, Elition X, uMR 780, Omega, Vida, Lumina, Architect, Premier is recorded as 171230, 232150, 242100, 309332, 230760, 230760, 229380 and 235990 ㎟, respectively ACSA% was 60.6, 60.3, 73.0, 70.0, 60.0, 60.0, 59.6, and 61,3%. In addition, DTB (Distance from Table top to Bore top) recorded 400, 407, 445, 495, 405, 405, 405, 403, and 412 mm. Through this study, it was confirmed that there is a difference between the bore size according to each MRI system and the actual cross-sectional area during MRI scanning. Accordingly, if we consider the internal actual area just not bore size at the clinical site, useful diagnostic images can be obtained in the end with better convenience.

A Study on Classification Model Development of Industry-Efificiency XR Technology and case Analysis (XR 기술 활용 산업-효용성 분류체계 개발 및 응용 사례 분석)

  • SeungMo Yun;ChoonSeong Leem;SeungHyun Ban
    • Journal of Service Research and Studies
    • /
    • v.12 no.4
    • /
    • pp.50-71
    • /
    • 2022
  • After the declaration of the Covid-19 pandemic impacted most of the industries resulting economic fallout. Firms sought for solutions of governments regulations to prevent spread of infectious diseases. This led to demand rise of digital layer and spectrums of virtual reality. Replacing the reality in to virtual and interactions with the digital contents by augmented reality, the consequences were decrement of human-to-human contact. Concerns of Covid-19 and public interests of digital solutions has led to significant amounts of research and developments of Virtual/Augment Reality resulted to driven up new terms of extended reality. However, the uses in industries and the characteristics of the extended reality are currently not defined. In this paper the goal is to define and classify the uses and characteristics of extended reality based on previous researches suggested by research institute. By developing a new classification models of extended realities core technology, uses of industries and utility to analyze trends of extended reality. Two separate classification models of uses of industries and utility will be used as a tool by creating a linkage matrix. The x-axis is divided by utiliy classification model of extended reality. The y-axis are divided into classification model of uses in industries. This matrix will be used as a tool to present a guideline for industry-utility development where extended reality can be served as a service

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Preparation of Chitosan-coated Magnetite Nanoparticles (키토산이 피복된 나노 크기의 자성체 분말 제조)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.102-106
    • /
    • 2006
  • Magnetic nanoparticles can be used for a variety of biomedical applications. They can be used in the targeted delivery of therapeutic agents in vivo, in the hyperthermic treatment of cancers. in magnetic resonance (MR) imaging as contrast agents and in the biomagnetic separations of biomolecules. We have synthesized magnetite $(Fe_3O_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 2 to 8nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. Nanoparticles, both oleate-coated and chitosan-coated, have been characterized by several techniques. Atomic farce microscope (AFM) was used to image the coated nanoparticles. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

Giant Magnetoresistance Properties of NiO Spin Valves with Naturally Oxidized Free Layer (자연산화된 자유층을 갖는 NiO 스핀밸브 박막의 자기저항특성)

  • 김종기;주호완;이기암;황도근;이상석
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.104-108
    • /
    • 2001
  • The effect of specular electron scattering on natural oxidation of free layer in NiO spin valves have been investigated. The magnetoresistance (MR) ratio and the exchange biasing field ( $H_{ex}$) of NiO(600 $\AA$)Ni$_{81}$$Fe_{19}$(50$\AA$)/Co(7 $\AA$)/Cu(20 $\AA$)/Co(7 $\AA$)Ni$_{81}$$Fe_{19}$(70 $\AA$) spin valves were increased from 4.9 % to 7.3 %, and 110 Oe to 170 Oe after natural oxidation in the atmosphere for 80 days, respectively. The sheet resistivity p decreased from 28$\mu$$\Omega$m to 17$\mu$$\Omega$m, but $\Delta$$\rho$ did not almost change after the oxidation. The spin valves enhanced by the specular electron scattering in the natural]y Co/NiFe/NiFe $O_{x}$ free layer were confirmed from the depth profiles using Auger electron spectroscopy.scopy..

  • PDF

Development of the Multi-Parametric Mapping Software Based on Functional Maps to Determine the Clinical Target Volumes (임상표적체적 결정을 위한 기능 영상 기반 생물학적 인자 맵핑 소프트웨어 개발)

  • Park, Ji-Yeon;Jung, Won-Gyun;Lee, Jeong-Woo;Lee, Kyoung-Nam;Ahn, Kook-Jin;Hong, Se-Mie;Juh, Ra-Hyeong;Choe, Bo-Young;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2010
  • To determine the clinical target volumes considering vascularity and cellularity of tumors, the software was developed for mapping of the analyzed biological clinical target volumes on anatomical images using regional cerebral blood volume (rCBV) maps and apparent diffusion coefficient (ADC) maps. The program provides the functions for integrated registrations using mutual information, affine transform and non-rigid registration. The registration accuracy is evaluated by the calculation of the overlapped ratio of segmented bone regions and average distance difference of contours between reference and registered images. The performance of the developed software was tested using multimodal images of a patient who has the residual tumor of high grade gliomas. Registration accuracy of about 74% and average 2.3 mm distance difference were calculated by the evaluation method of bone segmentation and contour extraction. The registration accuracy can be improved as higher as 4% by the manual adjustment functions. Advanced MR images are analyzed using color maps for rCBV maps and quantitative calculation based on region of interest (ROI) for ADC maps. Then, multi-parameters on the same voxels are plotted on plane and constitute the multi-functional parametric maps of which x and y axis representing rCBV and ADC values. According to the distributions of functional parameters, tumor regions showing the higher vascularity and cellularity are categorized according to the criteria corresponding malignant gliomas. Determined volumes reflecting pathological and physiological characteristics of tumors are marked on anatomical images. By applying the multi-functional images, errors arising from using one type of image would be reduced and local regions representing higher probability as tumor cells would be determined for radiation treatment plan. Biological tumor characteristics can be expressed using image registration and multi-functional parametric maps in the developed software. The software can be considered to delineate clinical target volumes using advanced MR images with anatomical images.

Image Comparisons using a Diethylenetriaminetriacetic Acid Derivative and Gd-DTPA (Diethylenetriaminetriacetic acid 유도체와 Gd-DTPA와의 영상비교)

  • Cho, Jung-Keun;Lee, Chai-Ho;Han, Tae-Jong;Lim, Cheong-Hwan;Kim, Jung-Nam;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.210-216
    • /
    • 2008
  • In this study, image comparisons were carried out using a MRI contrast medium which was derived by mixing a polyaminocarboxylic ligand and a gadolinium (III) transition metal which is paramagnetic and has good neutron absorbing capabilities with Gd-DTPA which is currently being used widely in the clinical setting. By using a 1.0T (Harmony, SIEMENS) MR equipment, phantoms of which 100cc of saline was diluted with a diethylenetriaminetriacetic acid derivative and Gd-DTPA were imaged. The amount of diethylenetriaminetriacetic acid and Gd-DTPA which was diluted into the 100cc of saline was 0.05mmol/L, 0.1mmol/L, 0.15mmol/L, 0.2mmol/L, 0.3mmol/L, 0.5mmol/L, 1.0mmol/L, 2.0mmol/L, 3.0mmol/L and 4.9mmol/L respectively. Head coils were used and while fixing the SE pulse sequence and image variable (as TE is 14ms, 1NEX with a 256x201 matrix), the signal intensity and simple contrast ratios according to changing concentrations and TR were compared with various TR at 300ms, 400ms, 500ms, 600ms, 700ms, 800ms, 900ms, 1000ms, 1200ms, 1400ms and 1600ms. According to the comparison results of the signal intensity of the image based on changes in contrast medium concentrations and TR, the differences in signal intensity between the two contrast mediums were found to be small at $1.0{\sim}2.0mmol/L$ when the highest signal intensity was achieved. However, at concentrations of 1.0mmol/L or less, the signal intensity was markedly higher in the Diethylenetriaminetriacetic acid derivative than in the Gd-DTPA complex. It was also found that the differences in the signal intensities demonstrated by the concentrations of the contrast mediums were affected by the TR. Accordingly, the efficacy of the Diethylenetriaminetriacetic acid derivative was shown to be better than the Gd-DTPA and also possible to get the optimum image quality by the use of an appropriate TR with appropriate concentrations of contrast medium.

Tissue Inhomogeneity Correction in Clinical Application of Transmission Dosimetry to Head and Neck Cancer Radiation Treatment (두경부 방사선 치료 환자에서 투과선량 알고리즘의 임상 적용시 불균질 조직 보정에 관한 연구)

  • Kim Suzy;Ha Sung Whan;Wu Hong Gyun;Huh Soon Nyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.155-163
    • /
    • 2004
  • Purpose : To confirm the reproducibility of in vivo transmission dosimetry system and the accuracy of the a1gorithms for the estimation of transmission dose in head and neck radiation therapy patients. Materials and Methods : From September 5 to 18, 2001, transmission dose measurements were peformed when radiotherapy was given to brain or head and neck cancer patients. The data of 35 patients who were treated more than three times and whose central axis of the beam was not blocked were analyzed in this study. To confirm the reproducibility of this system, transmission dose was measured before dally treatment and then repetitively every hour during the treatment time, with a field size of 10$\times$10 cm$^{2}$ and a delivery of 100 MU. The accuracy of the transmission dose calculation algorithms was confirmed by comparing estimated dose with measured dose. To accurately estimate transmission dose, tissue inhomogeneity correction was done. Results : The measurement variations during a day were within $\pm$0.5$\%$ and the dally variations in the checked period were within $\pm$ 1.0$\%$, which were acceptable for system reproducibility. The mean errors between estimated and measured doses were within $\pm$5.0$\%$ in Patients treated to the brain, $\pm$2.5$\%$ in head, and $\pm$ 5.0%$\%$in neck. Conclusion : The results of this study confirmed the reproducibility of our system and its usefulness and accuracy for dally treatment. We also found that tissue inhomogeneity correction was necessary for the accurate estimation of transmission dose in patients treated to the head and neck.

A Study on the Empathy of the Teenage Audience at the Cheong Kong Festival - Focusing on the 3rd Performing Arts Festival for Youth - (청공축제의 청소년 관객 공감 양상 연구 - '제3회 청소년을 위한 공연예술축제'를 중심으로)

  • Oh, Pan-Jin
    • (The) Research of the performance art and culture
    • /
    • no.39
    • /
    • pp.609-635
    • /
    • 2019
  • This study analyzed five official entries in the 3rd Cheong Kong Festival contest and analyzed the patterns of teen audience empathy. The tools used for this analysis were 'characters, acting, background and theme'. Firstly, characters were mostly teenagers and out-of-school teenagers, but there were other performances that focused on the relationship between teenagers and adults or focused on the youth, which the teen audience preferred. And they preferred realism acting to emotional acting and preferred musical acting to realism acting. In addition, the background of the events covered in the performance was evaluated to be like this: the closer the audience was to the youth, the higher the audience sympathized with the performance, and the closer the subject matter was to the youth's interest, the more positive it received. In summing up the opinions of the youth evaluation team, the first audience-participating Sinpa Theater, "Mr. X" was evaluated to expand the scope of teenagers to 20s and to show the negative and heavy reality as fun and beneficial one. Secondly, when it comes to non-prejudiced youth theatre "The Turtle", which have a high level of empathy, it was evaluated to shape the prejudice about others through the symbol of 'bag'. Thirdly, regarding the time-traveling retro-style youth theatre of the 'a jam-packed Bus', it was evaluated to be a well-made retro-style youth theatre. Regarding the 'Lunar Eclipse', which showed the aesthetic of the relationship, scenes were evaluated to be built with omission and restraint. Regarding "B Officer on and Love Letter", it was evaluated to be adapted to a musical from Hyun Jingun's novel, which was released 100 years ago. Lastly, the performance desired by the youth evaluation team was a performance with a high level of 'sympathy' and 'education'. In other words, they preferred performances that empathize with the emotions and thoughts of teenagers, and on the other hand, they wanted to see performances that allowed them to see the world broadly outside their own worlds. If youth theater is created by referring to the evaluation of youth as it is in this study, the audience will be more sympathetic to performances.