• Title/Summary/Keyword: worn surface

Search Result 288, Processing Time 0.056 seconds

Wearable Textile Strain Sensors (웨어러블 텍스타일 스트레인 센서 리뷰)

  • Roh, Jung-Sim
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.733-745
    • /
    • 2016
  • This paper provides a review of wearable textile strain sensors that can measure the deformation of the body surface according to the movements of the wearer. In previous studies, the requirements of textile strain sensors, materials and fabrication methods, as well as the principle of the strain sensing according to sensor structures were understood; furthermore, the factors that affect the sensing performance were critically reviewed and application studies were examined. Textile strain sensors should be able to show piezoresistive effects with consistent resistance-extension in response to the extensional deformations that are repeated when they are worn. Textile strain sensors with piezoresistivity are typically made using conductive yarn knit structures or carbon-based fillers or conducting polymer filler composite materials. For the accuracy and reliability of textile strain sensors, fabrication technologies that would minimize deformation hysteresis should be developed and processes to complement and analyze sensing results based on accurate understanding of the sensors' resistance-strain behavior are necessary. Since light-weighted, flexible, and highly elastic textile strain sensors can be worn by users without any inconvenience so that to enable the users to continuously collect data related to body movements, textile strain sensors are expected to become the core of human interface technologies with a wide range of applications in diverse areas.

Wear and Friction characteristics of $Cr_2$$O_2$ coating included $SiO_2$ and $TiO_2$ ($SiO_2$$TiO_2$가 첨가된 $Cr_2$$O_3$용사코팅의 마찰 .마멸 특성)

  • 서보현;김태형;김석삼
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.69-77
    • /
    • 2001
  • Wear and Friction characteristics of plasma-sprayed Cr$_2$O$_3$ coating and Cr$_2$O$_3$ coating included SiO$_2$ and TiO$_2$ against SiC ball have been investigated under different loads. Worn surfaces were observed by SEM and worn surfaces were analyzed by EDS. The Friction coefficient and the Wear resistance of Cr$_2$O$_3$-5SiO$_2$-3TiO$_2$coating was less than that of Cr$_2$O$_3$ coating. The main mechanisms were plastic deformation and brittle fracture. The film on surface were made by plastic deformation and compacted wear debris. This film protect wear of coating

  • PDF

A Study on the Wear Behavior of the Cu-TiB2 Composites (Cu-TiB2 복합재료의 마모거동에 관한 연구)

  • Kim Jung-Nam;Choi Jong-Un;Kang Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.15 no.1
    • /
    • pp.61-65
    • /
    • 2005
  • The titanium $diboride(TiB_2)$ has high strength(750MPa), high melting point $(3225^{\circ}C)\;and\;10\%$ IACS electrical conductivity. On this account, the dispersion hardening $Cu-TiB_2$ composites(MMCs) are a promising candidate for applications as electrical contact materials. MMCs for electrical contact materials can reduce material cost and resource consumption caused by wear, due to its good mechanical and electrical property. In this study, we attempt to prepare MMCs with various volume fraction and particle size of $TiB_2$ by means of hot extruded and cold drawn process. Dry sliding wear tests were performed on a pin-on-disk type wear tester, sliding against SM45C under the different applied loads. After wear testing, the microstructures of the worn surfaces were observed by SEM and the microhardnesses of the subsurface zone were measured.

The Effect of Test Variables on the Accuracy of Equo-Tip Hardness (Equo-Tip 경도값에 미치는 실험변수의 영향)

  • Nahm, S.H.;Jeon, S.B.;Kim, J.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.2
    • /
    • pp.32-36
    • /
    • 1990
  • For the accurate measurements of hardness in a material, it is necessary to have a thorough understanding of the effects of test variables on the accuracy of hardness value. For the rebound hardness test, major test variables are the radius of hammer ball tip, type of backing materials, size and roughness of the specimen. In this study, effects of these variables on Equo-Tip hardness value were investigated. Hardness measurements were carried out using WC balls with various sizes of worn-ot zone. The sample materials chosen for the experiments were commercial standard hardness blocks and SM45C steel bars subjected to either normalization or quench and temper treatments. As backing materials, aluminum, steel and rubber plates were used in all the experiments. Experimental results show that for the accurate measurements of Equo-tip hardness, it is necessary to use the hammer ball with a worn-out zone parameter of less than 0.23, and the recommended minimum thickness and width of the specimen are 25mm and 70mm, respectively. Further for the surface preparation, the specimens need to be polished with an emery paper of No. 400 or finer, and for the backing matrials, it is recommended to use steels or rubbers.

  • PDF

Effects of Ball Milling on Sliding Wear Behavior of Ni-Al Intermetallics Coated on Mild Steel through Induction Heating Process (고주파 연소합성 코팅된 Ni-Al계 금속간화합물의 미끄럼 마모 특성에 미치는 볼 밀링의 영향)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.34 no.6
    • /
    • pp.284-291
    • /
    • 2018
  • Ball-milling for reactant powders in advance and using an induction heating system for Ni-Al intermetallic coating process are known to enhance the reactivity of combustion synthesis. In this work, the effects of the charging weight ratio of ball to powder in ball-milling for reactant Ni-Al powders and the synthesizing temperature in induction heating on sliding wear behavior of the coating layers are investigated. Sliding wear behavior of the coating layers is examined against a tool steel using a pin-on-disc type sliding wear machine. As results, wear of the coating layer ball-milled without ball was severely worn out at the sliding speed of 2m/s, regardless of the synthesizing temperature in induction heating. However, the wear rate of the coating layers at the sliding speed was remarkably decreased with increasing the charging weight ratio of ball in ball-milling for reactant powders. This can be explained by the fact that the void in the coating layer is disappeared and the coating layer is densified by the ball-milling. The evidence showed that pitting damages were disappeared on the worn surface of ball-milled coating layer. Consequentially, the Ni-Al intermetallic coating layer could have better wear resistance at all sliding speed ranges with the ball-milling for reactant powders in advance.

The Variation of the Slip Resistance with Wear of Floor (바닥재 마모에 따른 미끄럼 저항 변화)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.14-20
    • /
    • 2013
  • All most of floors can become less slip resistant with wear. The deterioration of slip resistance can often occur rapidly. So relatively new products can become hazardous within a short period of time. The main objective of this study was the comparison of slip resistance variations caused by traffic wear and accelerative wear. The second objective was to ascertain the effect of wear, and to find out the causes of slip resistance change. Although statistical differences were observed between results of traffic wear and accelerative wear, the trend of the variations of slip resistance caused by traffic wear and accelerative wear was very similar. The measured slip resistance of tested floor changed up to 29%(and 26.5%) after 100,000 steps(and 750 cycles). As the traffic wear and accelerative wear were progressed, the surface roughness of the tested floor became smoother, and so the floor became more slippery under the wet condition. The abraded(worn out) floor surface tended to become hydrophilic surface, while the new floor surface tended to show hydrophobic nature. This phenomenon would change the wettability of floor surface, and the wettability would affect the variation of slip resistance.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Friction and Wear Properties of Plasma-sprayed Cr2O3-MoO3Composite Coatings at Room Temperature (MoO3가 첨가된 Cr2O3플라즈마 용사코팅의 상온 마찰 마멸 특성)

  • 여인웅;안효석;임대순
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.79-85
    • /
    • 2002
  • Plasma-sprayed Cr$_2$O$_3$-based coatings containing MoO$_3$were studied to gain a better understanding of the influence of MoO$_3$composition in the coatings on their tribological behaviour. A reciprocal type tribo-tester was employed to examine friction and wear behavior of the specimens at room temperature. The physical characteristics of worn surfaces were investigated by scanning electron microscopy and chemical composition of the coating surfaces was analyzed using a X-ray photoelectron spectrometer. The results showed that friction coefficient of the MoO$_3$-added coatings were lower than those without MoO$_3$addition. However pure Cr$_2$O$_3$coating showed the lowest wear loss at the self-mated test. The larger protecting layers were observed at the worn surface of plasma spray coated specimens with MoO$_3$addition. XPS analysis of the protecting layer indicated that MoO$_3$composition was dominantly formed at the surface. MoO$_3$composition in the protecting layer appears to be more favorable in reducing the friction.

A Study on the Wear comfort and the Wearing Effects of Maternity Girdles (시판 임산부용 거들의 착용감 및 착용효과에 관한 연구)

  • 최혜선
    • Journal of the Korean Home Economics Association
    • /
    • v.29 no.3
    • /
    • pp.11-21
    • /
    • 1991
  • The study has been intended to find out meaningful information about the development of a prototype of enhanced maternity girdle. The girdles of three different models which were available in the market have been carried out by three six-month pregnant women and three nine-month pregnant women. The results of the study are as follows. 1. All three girdles showed improved wear effects in order of model A, model B, model C. Body surface area measurement and two body surface angles of abdomen are significantly dicreased by wearing and type of girdles. It is presumed that the reasons of good wear effect of model A is low expansion rate of the material and tight fitness of the model. Model B is made of material whose expansion rate is higher than model A. Also abdominal part of the model B is bias cut which is considered to result better stretch and consequently lower wear effect. 2. For wear comfort, subjects preferred in order of model B, model C, and model A. All subjects feel more comfortable after wearing girdles 30 minutes than after wearing girdles 1 day. Comparing 2 subject groups, 6-month pregnant group feel more comfortable about wearing girdles than 9-month pregnant group. 3. The girdles are expanded as a whole in order of model B, model C and model A. Considering the expansion rate of some specific area of the girdles, abdominal area expands more than hip area which expands more than thigh area. The expansion rates of girdles worn to 6-month pregnant group are very low at all area, while the expansion rates of girdles worn to 9-month pregnant group are very high.

  • PDF

A Study on Characteristics of Laser Cladding Layer of STS316L (STS316L 분말의 레이저 클래딩층 특성에 관한 연구)

  • Hong, SungMoo;Oh, JaeYong;Kim, DongSeob;Chang, SeungCheol;Shin, BoSung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.53-56
    • /
    • 2017
  • Laser cladding is a technique for forming beads by melt-sintering with a laser while directly feeding metal powder onto the base material through nozzles. This technique, which is applied in laser surface treatment technology, is useful for repairing broken or worn parts by allowing selective formation of the surface layer of the base metal material. In this paper, laser cladding process was performed on STS316L powder using high power continuous wave laser with IR wavelength and the cladding characteristics according to process conditions were experimentally analyzed.