• Title/Summary/Keyword: wood-based floor

Search Result 39, Processing Time 0.021 seconds

Heating and Cooling Energy Demand Evaluating of Standard Houses According to Layer Component of Masonry, Concrete and Wood Frame Using PHPP (PHPP를 활용한 조적, 콘크리트, 목조 레이어 구성별 표준주택 냉·난방 에너지 요구량 평가)

  • Kang, Yujin;Lee, Junhee;Lee, Hwayoung;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • A lot of the energy are consumed on heating and cooling in buildings. The buildings need to minimize the heating and cooling loads for $CO_2$ emissions and energy consumption reduction. In recently, also demand of detached houses were increase while the residential culture was changed. The structure of the domestic detached houses can be divided into masonry, concrete, wood frame houses. Therefore, in this study, the heating and cooling load and energy demand were analyzed on the equal area detached house consisting of three structural methods (Masonry, Concrete, Wood frame). Layer of wall, roof, and floor were composited by structure. Thermal transmittance (U-value) of each layer was using the PHPP calculation for considering stud, such as the wood frame wall. In addition, the case of without considering for studs in wood frame wall (Non-studs) was analyzed in order to compare the difference between studs or not. Analysis was performed using self-developed heating and cooling load calculation program (CHLC) based excel and ECO2. The results of cooling and heating load and energy demand showed the highest values in the wood frame structure, and the concrete structure were confirmed to maintain a high value secondly. Two structure were determined to be disadvantageous on the energy consumption. Consequently, the masonry structure have an advantage over the other structure under the identical conditions. It was determined that if the except for thermal bridges due to the studs in the wood frame structure, it can be reduced the energy consumption.

A Study on Deflection Characteristics of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 변형 특성에 관한 연구)

  • Pi, Duck-Won;Kang, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.42-50
    • /
    • 2013
  • Since 1990's, a plywood for flooring base has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as crossband layers was checked by deflection experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on deflection are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are M type of density gradient on the other hand Eucalyptus samples are W type of density gradient. The more samples have high density difference, the more deformation was checked. A sample which has big density difference between core and cross bands layer warp more also deform. Flooring was deformed smaller than plywood and samples which have big density difference was deformed more.

Evaluation of Airborne and Surface Lead Concentrations in Preschool Classroom (유아교육시설의 표면 및 공기 중 납 농도 평가)

  • Yoon, Chung-Sik;Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.1-7
    • /
    • 2006
  • This study was performed to investigate airborne lead concentration and surface lead contents in preschool facilities. Arithmetic mean of indoor lead concentration in urban area was $44.7\;ng/m^3$ (Geometric mean $32.1\;ng/m^3$) whereas outdoor concentration was $39.5\;ng/m^3$ (GM $22.8\;ng/m^3$). In rural area, airborne lead concentrations were $14.2\;ng/m^3\;(GM\;7.9 ng/m^3),\;12.6\;ng/m^3\;(GM\;5.6 ng/m^3)$, respectively. There is statistical significance of the lead concentrations among the locations of preschool facilities. About $37\%$ of qualitative lead check samples was positive and mainly was found in lead based paint. Though lead concentrations on the floor and window sill were well below the US EPA and HUD standard (floor $40\;{\mu}g/ft^2\;(4.3\;{\mu}g/100\;cm^2)$, window sill $250\;{\mu}g/ft^2\;(26.9\;{\mu}g/100\;cm^2)$, respectively), there were much samples which exceed the standard, i.e., $29\%$ of surface wall, $20\%$ of the desk and chair, $100\%$ of painted wood box of tested samples. In view of our study and hazard of lead to children, we recommended that the contents of lead in preschool facilities should be lowered as possible.

A Field Study on the Facilities and Equipments of the Traditional Farmhouse in Lungching, China (중국 연변 조선족 전통농가의 시설설비 실태조사)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.6
    • /
    • pp.123-132
    • /
    • 1998
  • This paper is a part of "The Study of the Traditionla Korean Ethnic Farmhousing in Yanbian, China" The purpose of this study is to investigate the facilities and equipments of the traditional farmhouse in the villages of Lungching China. The data is collected from 124 households in the villages based on the survey conducted using questionnaire and photograph. The major findings are: 1) The people in farmhouse use wood as a fuel for cooking and the method of cooking is traditional style using their iron pots. 2) Heating system of the house is ondol type of heating using. wood which is also traditional type. This means that the floor heating of the house and cooking food can be carried out simultaneously. 3) Even though pump system and running water system are the two kinds of water supply that are available in the villages, majority of people use pump system. Many houses have no drainage facilities but few houses have got bad drainage system. 4) From the planning stage of the farm house facilities and equipments for ventilation is not considered and hence it is not provided in most of the houses. 5) Farmhouses are oriented to the south and the windows and the doors are covered either with viny1 or cloth during winter time effecting the lighting system of the house. 6)Many of the houses use incandescent lights. But the switchs and the electric Outlets are short in number. 7) Sanitation facilities are worst equipped compared to other facilities present in Lungching villages of China. of China.

  • PDF

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.

Suggestion of Thermal Environment Miniature for Evaluation of Heating Efficiency Based on Thermal Conductivity Measurement Method of Building Materials (건축재료의 열전도율 측정방법에 의한 바닥재 난방효율 평가용 열환경 모형 제안)

  • Jeon, Ji-Soo;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.269-280
    • /
    • 2011
  • Today, global warming is one of main problems all over the world. The cause of the global warming is carbon dioxide outbreak by the rapidly increasing energy use. Therefore, it is necessary to save energy in each industrious field. It was investigated that the half of total energy consumption over the world was used for construction and building. Therefore, the saving of the building energy plays a significant role in decreasing total energy consumption. With the considerable increase in building energy consumption, a green building rating system and certification are required to reduce building energy consumption and $CO_2$ emissions. Of various elements reducing building energy, the thermal conductivity of materials affects the energy consumption as a basic element, which is directly related with reducing energy consumption. In particular, as the thermal conductivity of finishing materials is an important factor to decide heating energy efficiency of floor heating system, the investigation and development are necessary.

A Study on Heat Transfer of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 열전달 특성에 관한 연구)

  • Pi, Duck-Won;Choi, Song-Kyu;Kang, Ho-Yang;Kang, Seog-Goo
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.3
    • /
    • pp.298-304
    • /
    • 2012
  • Since 1990's, a flooring based on plywood has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as a core layer was checked by heat transfer experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on heat transfer are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are 'M' type of density gradient on the other hand Eucalyptus samples are 'W' type of density gradient.

  • PDF

The Strength and Applications of OSB Gusset Trusses for Field Assembly (현장조립용 OSB 덧댐판 트러스의 강도 및 활용방안)

  • Kim, Tae-Woo;Ha, Bin;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.708-713
    • /
    • 2014
  • Trusses are widely used for wooden houses in the areas where wood construction in generalized for residential housings such as North America, Australian, New Zealand. In Korea, joist and rafter system is generally used because of the production cost, transportation cost and lack of experience required for truss manufacturing. In this study, roof trusses and flat trusses were manufactured by using oriented strand board (OSB) gusset plates for field assembly and tested under bending load to obtain the allowable loads. The allowable load and the actual load of 6m span roof trusses were 10.60 kN and 5.26 kN, respectively, which is regarded to be sufficient for use in construction. The allowable load and the actual load of 6m span floor flat trusses were 7.18 kN and 7.43 kN, respectively. For flat trusses, the allowable load is slightly lower than the actual load but the difference in very small, and it is thought that flat trusses can be used for construction by applying small change of structures and members.

Interior Planning for Classrooms in Kindergarten (유치원 보육실 실내환경계획 방향에 관한연구)

  • 황연숙;박희진
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.62-68
    • /
    • 1998
  • Children develop in direct relation and response to their physical environment, The purposes of this study were to investigate the current interior design conditions of classrooms in kindergarten and to provide interior planning guidelines for children's behavioral and developmental improvement and better educational environment. Data were collected through interview and questionnaire survey. The sample included 239 teachers who were employed in 23 kindergartens located in Pusan. The data were analyzed by using SPSS-PC. The major findings were as follows; (1) Wood and wallpapers which provide various colors and patterns are recommendable as a classroom finish rather than paint which looks monotonous. (2) Teachers preferred 7 or 8 activity centers in classroom and furniture or partition is the best when dividing space. (3) Classroom should be large enough to locate various types of furniture that designed based on child-size and objects to store. (4) Activity centers should be lit by different types of task lighting such as floor lamp and backer to provide sufficient level of light.

  • PDF

A Study on the Preference for the Components of the Department Store Interior Design Image -Focusing on Women Customers Resident in Seoul- (백화점 실내디자인 이미지의 구성요소 선호도에 관한 연구)

  • 서종호;최상헌
    • Korean Institute of Interior Design Journal
    • /
    • no.9
    • /
    • pp.3-9
    • /
    • 1996
  • When a certain particular department store is chosen by customers due to the good image, the department store will have provided for the conditions that it can precede in competition with other department stores. Based upon it, a survey was made of preference for the department store interior design image component. In order to make the department store image better based upon this study results, the designer should remember that department store is possessed of display and circultation planinorder to give consume the good image. And , as a result of analyzing customers' preference for the details of the interior design image component, the area, primary components of the department store space, should take on specialization , though narrow. The circulation should constitute the free flow system. The ornamental illumination should be emphasized for the secondary component of the department store space. The color planing should be made that is oriented to seasonality and products. The floor should finished with wood. The department store interior should be decorated in a modern and simple form. The display of the department store should be made in a fashion that it takes on seasonality and artistry. These measures can be said to be the desirable method to provide a good image for women customers paying a visit to the department store.

  • PDF