• 제목/요약/키워드: winding number

검색결과 194건 처리시간 0.028초

국산자기재료를 이용한 비대칭자속분포 단상유도기구 (A Study On The Performances Of A Single-Phase Motor With Non-Quadrature Stator Windings Using Domestic Magnetic Materials.)

  • 박민호
    • 전기의세계
    • /
    • 제21권3호
    • /
    • pp.41-47
    • /
    • 1972
  • The requirements of a successful design for single phase induction motors with a high efficiency have, in recent years, led to the use of non-quadrature stator windings motors in which a high starting torque is a prime requisite. The capacitor motor is one of above machines in which various possible forms of asymmetry can be occur. These forms of asymmetry in the stator phase windings, encountered in machine designs, are 1) an asymmetrical disposition in space of their magnetic axes, 2) a difference in their effective number of turns, 3) a difference in the distribution of their coil groups per pole and 4) amounts of capacitance of an auxiary winding. In order to apply the effective performance prediction of these form to motors, mading of lower quality-domestic magnetic materials, the analysis and the experimental investigations of its sample motors are described in this paper. The utility of such a motor is demonstrated and it is shown that the effects- a good efficiency, good power factor and high starting torque-of the motor mechanism with non-quadrature stator phase windings can development disadvantages by using the lower quality-domestis magnetic materials.

  • PDF

직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석 (Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers)

  • 김희중;배병열;전영수;한병문;김현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

가전기기용전동기의 전자소음과 진동의 방지대책에 관한 연구 (Study on the Reduction Method of Magnetic Noise and Vibration in Home Electric Motors)

  • 황영문;조철제
    • 전기의세계
    • /
    • 제26권5호
    • /
    • pp.74-82
    • /
    • 1977
  • This study is to present a method for reductin of noise and vibration of home electric motors coupled to the mechanical load causing relatively big amplitude of vibration. The noise and vibration factors have been analysed in the divisions such as the pattern related to the armature reaction, the pattern related to the circulating current by induction and the other patterns those are affected by a dditive magnetic field and have an effect on mechanical constants. From the systematic mutual relations between the patterns and daping effects, it is possible to derive the fundamental measure for reduction of noise and vibration. Vibration measurements and analysis were carried out in accordance with the planned experimentation and thre object model was chosen randomly from the production line in a factory where home electric machines were mass-produced. Based on the above-mentioned fundamental measure, suppression effects on noise and vibration have been analysed according to the number of slots, the amount of rotor skew and the way the stator winding connection was series or parallel.

  • PDF

유한요소법과 프라이자흐모델이 결합된 해석기법을 이용한 슬롯수에 따른 손실과 토크 특성 을 통한 동기형 릴럭턴스 전동기 특성분석 (A Novel Stator Design of Synchronous Reluctance Motor by Loss & Torque Characteristics Related to Slot Numbers using Coupled Preisach Model & FEM)

  • 송한상;이중호;이병두
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1053-1054
    • /
    • 2011
  • This paper deals with the stator design solution of a synchronous reluctance motor (SynRM) with various slot numbers by loss & torque characteristics related to the slot open and teeth width using coupled Preisach modeling & FEM. The coupled Finite Elements Analysis (FEA) & Preisach model have been used to evaluate the nonlinear solution. Comparisons are given with characteristics of SynRM according to stator winding, slot number, slot open and teeth width variation.

  • PDF

전류원 방식 푸시-풀 공진형 인버터로 구성된 단일단 고역률 형광등용 전자식 안정기 (Electronic Ballast using Current-Fed Push-Pull Resonant Inverter with Bypassing Capapcitor for Power Factor Correction)

  • 류태하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.489-492
    • /
    • 2000
  • A novel low-cost simple and unity-power-factor electronic ballast is presented. The proposed electronic ballast employs a bypassing capacitor and load networks composed of ballast capacitors and small charge pump capacitors as power factor correction circuit combined with the secondary winding of the transformer in the self-excited current-fed push-pull resonant inverter(CF-PPRI) resulting in cost-effectiveness and higher efficiency. By analyzing the principles of power factor correction mathematically optimum design guidelines are presented. Since the lamps are used in power factor correction stage the input power is automatically adjusted according to the number of the lamps.

  • PDF

가변탭 변압기를 사용한 급전용량 증가 검토 (Examination of Increasing Power Delivery Capacity with variable Tab Autotransformer)

  • 이장무;한문섭;이한민;김주락;김길동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1163_1164
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing train number, electric load at feeding system are increasing and collecting voltage of train are going down. To increase electric load and collecting voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

IM(Integrated Magnetics) 방식을 이용한 Three-Level 컨버터의 자기회로 해석에 관한 연구 (The analysis of magnetic circuit for the Three-Level converter using IM(Integrated Magnetics))

  • 배진용;김용;권순도;조규만;이규훈;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.218-222
    • /
    • 2007
  • This paper present the Three-Level converter for high power application. In converter system, magnetic components are important devices used for energy storage, energy transfer, galvanic isolation and filtering. The proposed Three-Level converter is to reduce the number of magnetic components. The secondary rectification was discussed by a single core transformer winding. The result of the analysis are verified using 1kW prototype.

  • PDF

APPLICATION OF ACOUSTIC EMISSION FOR DIAGNOSIS OF QUENCH IN SUPER CONDUCTIVE MAGNET AT CRYOGENIC TEMPERATURE

  • Lee, Joon-Hyun;Lee, Min-Rae;Kwon, Young-Kin;Song, Bong-Min
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.160-165
    • /
    • 2007
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE) technique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current.

  • PDF

새로운 위상변성 방법 (A New Method of Phase Transformation)

  • 오상세
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.38-41
    • /
    • 1964
  • This thesis is aimed to obtain efficiently economically any desired phases and single phase transformer without unbalance by using only a new transformer, applying the theory of rotating magnetic field. The brief construction and principle is as floow: two pieces of similar ring cores, triangular cores or polygonal cores are located on the upper and lower sides with equidistance. And the some number of similar leg cores, shaped a square-pillar or a sylinder, are arranged at equidistant of the core section. Ring windings or polyphase windings of AC machines are adopted as a winding method on the upper and lower cores. Three phase AC is applied to the primary windings on these cores so that the rotating magnetic field is induced on the cores and this magnetic fluxes pass through each of the secondary windings on the leg-cores with some difference in time.

  • PDF

양수발전소 발전-전동기 운전중 감시 시스템의 개발 (Development of On-Line Monitoring System for Pumped Storage Generator/Motor)

  • 김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.