• 제목/요약/키워드: wide connection

검색결과 334건 처리시간 0.025초

Fontan 수술성적에 대한 보고 - 45례 - (Results of Fontan Operation - 45 Cases Report -)

  • 원용순
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.25-31
    • /
    • 1989
  • Forty-five patients, aged 16 months to 15.5 years mean 69 months, with a wide variety of cardiac malformations underwent the modified Fontan operation between Sep. 1986 to Aug. 1988. Nineteen patients had previously undergone palliative operations mainly modified B-T shunt. Twenty patients had a mean pulmonary artery pressure greater than 15 mmHg, with nine operative deaths. Thirteen patients had anomalies of systemic venous connection and seven patients had anomalies of pulmonary venous connection. There were eighteen patients under the age 4 years and fifteen of them survived [83.3%]. Eighteen patients had a pulmonary vascular resistance [PVR] more than 2.5U/m, and nine died [50%] whereas two of twenty-three with a PVR less than 2.5U/m died[8.6%]. PVR and anomalies of pulmonary venous connection had a significant influence on survival, but age and anomalies of systemic venous connection did not. Amount of pleural effusion drained postoperatively and PVR had positive linear correlation. Pulmonary artery pressure was not an independent predictor of outcome and pulmonary artery pressure alone should not contraindicate a Fontan procedure if PVR is low. In general, the Fontan operation should be done at a younger age less than 4 year to avoid ventricular dysfunction due to long-standing exposure to hypoxia.

  • PDF

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

Comparison of Two Meta-Analysis Methods: Inverse-Variance-Weighted Average and Weighted Sum of Z-Scores

  • Lee, Cue Hyunkyu;Cook, Seungho;Lee, Ji Sung;Han, Buhm
    • Genomics & Informatics
    • /
    • 제14권4호
    • /
    • pp.173-180
    • /
    • 2016
  • The meta-analysis has become a widely used tool for many applications in bioinformatics, including genome-wide association studies. A commonly used approach for meta-analysis is the fixed effects model approach, for which there are two popular methods: the inverse variance-weighted average method and weighted sum of z-scores method. Although previous studies have shown that the two methods perform similarly, their characteristics and their relationship have not been thoroughly investigated. In this paper, we investigate the optimal characteristics of the two methods and show the connection between the two methods. We demonstrate that the each method is optimized for a unique goal, which gives us insight into the optimal weights for the weighted sum of z-scores method. We examine the connection between the two methods both analytically and empirically and show that their resulting statistics become equivalent under certain assumptions. Finally, we apply both methods to the Wellcome Trust Case Control Consortium data and demonstrate that the two methods can give distinct results in certain study designs.

상·하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동 (Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle)

  • 이성주;김주우
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.191-204
    • /
    • 2014
  • 본 논문에서는 반복하중을 받는 CFT 합성골조에서 부분강접 접합부인 상 하부 ㄱ형강 접합부의 휨모멘트 내력을 구하기 위하여 체계적인 수치해석이 수행되었다. 고강도강 연결봉으로 조립된 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 ㄱ형강의 두께 및 고강도 강봉 게이지 거리로 상 하부 ㄱ형강 접합의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.

강판 콘크리트 구조 접합부의 설계방식에 따른 검증실험 연구 (A Study on Verification Tests according to Connection Design Methods of Steel Plate Concrete Structures)

  • 황경민;이경진;양현정;김원기
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 본 연구에서는 원전 구조물 내 철근 콘크리트 구조와 강판 콘크리트 구조가 이질접합된 경우를 모사하기 위하여, 상하부 표면강판 간에 타이바를, 상하부 리브재 간에 타이형강을 구성한 보형 실험체를 제작하여 실험체의 면외 휨 거동특성을 확인하고자 하였다. 실험결과, 실험체의 연성거동을 검증하였으며, 타이바와 타이형강이 콘크리트 및 강판의 분리를 방지함으로써 접합부의 취성파괴를 막아주고 있음을 확인하였다. 또한, #14 주철근으로 구성한 강판 콘크리트 구조 접합부에 대하여 두 가지 형태의 기계적 정착이음 방식에 따른 인장실험을 수행함으로써 본 방식의 설계 적정성을 평가하였다. 실험결과, 두 실험체 모두 주철근이 항복에 도달할 때까지 철근의 정착 및 연결 기능을 탄성한도 내에서 건전히 수행하고 있음을 확인하였다.

초광각 무선 디지털 전자 내시경 모듈에 관한 연구 (A Study on a Ultra-wide-angle Wireless Digital Electronic Endoscope Modules)

  • 심동하;김형오;이봉주;홍승철;이재선;차재상
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.570-574
    • /
    • 2014
  • This paper proposes a wireless digital endoscope with a ultra-wide-angle view. Two key components are implemented to demonstrate the feasibility of the proposed endoscope. First, a ultra-wide-angle lens module with the field of view of 144 degree and F-number of 2.2 is designed and manufactured. Second, a wireless module for a high-speed video transfer is implemented using a USB device server and wireless LAN router. The wireless module can directly transfer a streaming video to a computer with the resolution of 1920x1080, frame rate of 30 fps, and data rate of 53.3 Mbps without an internet connection. Since the wireless module supports two USB devices, two spots can be simultaneously observed using the proposed endoscope.

제한된 환경에서의 해수냉각펌프용 유도전동기 최대출력 운전을 위한 약계자 제어 (Advanced Field Weakening Control for Maximum Output Power Operation of Seawater Cooling Pump Induction Motor in a Limited Environment)

  • 손영득;서용주;정준형;김장목
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.540-546
    • /
    • 2013
  • The induction motor is used for driving the special equipments such as warship and submarine pump due to robust structure and simple maintenance. Domestic and foreign warships use a wide range of voltages and the DC voltage sources mainly from battery. In the low voltage level, the ${\Delta}$-connection operation of induction motor can be used for the maximum power. However, the temperature of the inverter increases because of the high input current. On the other hand, Y-connection operation of the induction motor does not cause a problem of temperature because of the low input current compared to the ${\Delta}$-connection. But the lack of the supply voltage can not be avoided. Therefore, this paper suggests the algorithm of the optimum field weakening control to extend the operating range of the induction motor with maximum power in a limited thermal and DC voltage condition.

축산폐기물 바이오 에너지 분산발전용 전처리시스템 개발 (Developement for Pretreatment System of Distributed Power Generation by using Livestock BIO-ENERGY)

  • 허광범;박정극;이정빈;임상규;김재훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.585-588
    • /
    • 2007
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection constrains. KEPCO (Korea Electric Power Corporation) is performing the project to develope the Distributed Micro Gas Turbine (MGT) technolgies by using Swine BIO-ENERGY. This paper describes the plans and strategies for the renewable energy of MGT on actual grid-connection under Korean situations. KEPCO also, has a research plan on bio-gas pretreatment system applicable to our domestic swine renewable resources and is performing concept design of pilot plant to test grid operation. In addition, this testing will be conducted in order to respond to a wide variety of needs for application and economic evaluation in the field of On-site generation.

  • PDF

마이크로 가스터빈 발전시스템 운전신뢰성평가 (Evaluation of Operation Reliability for Micro Gas Turbine(MGT) Power Generation System)

  • 김재훈;허광범
    • 한국소음진동공학회논문집
    • /
    • 제17권5호
    • /
    • pp.448-455
    • /
    • 2007
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. This paper describes the procedures and results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of MGT was developed, so that it will be able to analyze or propose new distributed generation system using MGT. The field test was conducted in order to respond to a wide variety of needs for noise reduction and utilization and its performance was evaluated in consideration of its operational problems. The MGT is successfully supplying electricity to Korean grids with satisfying various regulations. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.