DOI QR코드

DOI QR Code

Evaluation of Operation Reliability for Micro Gas Turbine(MGT) Power Generation System

마이크로 가스터빈 발전시스템 운전신뢰성평가

  • 김재훈 (충남대학교 기계설계공학과) ;
  • 허광범 (한국전력공사 전력연구원)
  • Published : 2007.05.20

Abstract

As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. This paper describes the procedures and results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of MGT was developed, so that it will be able to analyze or propose new distributed generation system using MGT. The field test was conducted in order to respond to a wide variety of needs for noise reduction and utilization and its performance was evaluated in consideration of its operational problems. The MGT is successfully supplying electricity to Korean grids with satisfying various regulations. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

Keywords

References

  1. Kashiwagi Takao, Hashimoto Naoto, Kanaya Toshinobu., 2001, Micro Power Revolution, Vol. 2, pp. 107-115
  2. Capstone Corporation, 2003, 'MicroTurbine Model C60 System Manual', Vol. 3 pp. 57-98
  3. Rhim, S. K., Hur, K. B., Sohn, W. S., and Choi, K. S., 2003, 'Development of Grid Connection Power Technology for on Site Type MGT', Report of KEPRI., pp. 128-168
  4. IEEE 519, 2002, IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE Standard Board. 1992[7] IEC 61000-3-3 Limitation of Voltage Fluctuations and Flicker in Public Low-voltage Supply Systems, pp. 88-98
  5. IEC 61000-3-5, 1994, Limitation of Voltage Fluctuations and Flicker in Low-voltage Power Supply Systems, pp. 122-154
  6. Hur, K.-B. and Kim, J.-H. 2006, 'Study on the Performance Characteristics of MGT Co-generation System', Transactions of the Korean Society for Noise and Vibration Engineering Vol. 16 No. 9 pp. 964-970 https://doi.org/10.5050/KSNVN.2006.16.9.964