• Title/Summary/Keyword: well loss

Search Result 3,554, Processing Time 0.033 seconds

A Lookup Table Based Loss Minimizing Control for FCEV Permanent Magnet Synchronous Motors

  • Lee, Jung-Gi;Nam, Kwang-Hee;Lee, Sun-Ho;Choi, Soe-Ho;Kwon, Soon-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.201-210
    • /
    • 2009
  • A loss minimizing controller is developed for a fuel cell electric vehicle (FCEV) permanent magnet synchronous motor (PMSM). The PMSM losses are modeled by some experimental equations. Applying Lagrangian to the loss function, a necessary condition for the optimality appears to be a fourth order polynomial, and the loss minimizing solutions are obtained by a simple numerical approach. On the other hand, the loss minimizing solutions are found by scanning the motor loss in the entire operating region. The two results agree well. The loss minimizing current sets for given torque and speed are made into a table, which is utilized as a look-up in the current control loop.

Study on the Measurement-Based Packet Loss Rates Assuring for End-to-End Delay-Constrained Traffic Flow (지연 제한 트래픽 흐름에 대한 측정 기반 패킷 손실률 보장에 관한 연구)

  • Kim, Taejoon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1030-1037
    • /
    • 2017
  • Traffic flows of real-time multimedia services such as Internet phone and IPTV are bounded on the end-to-end delay. Packets violating their delay limits will be dropped at a router because of not useful anymore. Service providers promise the quality of their providing services in terms of SLA(Service Level Agreement), and they, especially, have to guarantee the packet loss rates listed in the SLA. This paper is about a method to guarantee the required packet loss rate of each traffic flow keeping the high network resource utilization as well. In details, it assures the required loss rate by adjusting adaptively the timestamps of packets of the flow according to the difference between the required and measured loss rates in the lossy Weighted Fair Queuing(WFQ) scheduler. The proposed method is expected to be highly applicable because of assuring the packet loss rates regardless of the fluctuations of offered traffic load in terms of quality of services and statistical characteristics.

Reference-Intrinstic Analysis for the Difference between Two Normal Means

  • Jang, Eun-Jin;Kim, Dal-Ho;Lee, Kyeong-Eun
    • Communications for Statistical Applications and Methods
    • /
    • v.14 no.1
    • /
    • pp.11-21
    • /
    • 2007
  • In this paper, we consider a decision-theoretic oriented, objective Bayesian inference for the difference between two normal means with unknown com-mon variance. We derive the Bayesian reference criterion as well as the intrinsic estimator and the credible region which correspond to the intrinsic discrepancy loss and the reference prior. We illustrate our results using real data analysis as well as simulation study.

A Study on Process Capability Index using Reflected Normal Loss Function (역정규 손실함수를 이용한 공정능력지수에 관한 연구)

  • 정영배;문혜진
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.66-78
    • /
    • 2002
  • Process capability indices are being used as indicators for measurements of process capability for SPC of quality assurance system in industries. In view of the enhancement of customer satisfaction, process capability indices in which loss functions are used to deal with the economic loss In the processes deviated from the target, are in an adequate representation of the customer's perception of quality In this connection, the loss function has become increasingly important in quality assurance. Taguchi uses a modified form of the quadratic loss function to demonstrate the need to consider the proximity to the target while assessing its quality. But this traditional quadratic loss function is inadequate to assessing the quality and quality improvement since different processes have different sets of economic consequences on the manufacturing, Thereby, a flexible approach to the development of the loss function needs to be desired. In this paper, we introduce an easily understood loss function, based on reflection of probability density function of the normal distribution. That is, the Reflected Normal Loss function can be adapted to an asymmetric loss as well as to a symmetric loss around the target. We propose that, instead of the process variation, a new capability index, CpI using the Reflected Normal Loss Function that can accurately reflect the losses associated with the process and a new capability index CpI Is compared with the classical indices as $C_{p}$ , $C_{pk}$, $C_{pm}$ and $C_{pm}$ $^{+}$.>.+/./.

A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay (Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구)

  • Kim, Kwnag-Hyun;Park, Ji-Kyung;Kim, Jun-Hyeok;Kim, Doo-Ung;Kang, Sung-Bum;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

Image Translation: Verifiable Image Transformation Networks for Face Sketch-Photo and Photo-Sketch (영상변형:얼굴 스케치와 사진간의 증명가능한 영상변형 네트워크)

  • Sung, Thai-Leang;Lee, Hyo-Jong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.451-454
    • /
    • 2019
  • In this paper, we propose a verifiable image transformation networks to transform face sketch to photo and vice versa. Face sketch-photo is very popular in computer vision applications. It has been used in some specific official departments such as law enforcement and digital entertainment. There are several existing face sketch-photo synthesizing methods that use feed-forward convolution neural networks; however, it is hard to assure whether the results of the methods are well mapped by depending only on loss values or accuracy results alone. In our approach, we use two Resnet encoder-decoder networks as image transformation networks. One is for sketch-photo and another is for photo-sketch. They depend on each other to verify their output results during training. For example, using photo-sketch transformation networks to verify the photo result of sketch-photo by inputting the result to the photo-sketch transformation networks and find loss between the reversed transformed result with ground-truth sketch. Likely, we can verify the sketch result as well in a reverse way. Our networks contain two loss functions such as sketch-photo loss and photo-sketch loss for the basic transformation stages and the other two-loss functions such as sketch-photo verification loss and photo-sketch verification loss for the verification stages. Our experiment results on CUFS dataset achieve reasonable results compared with the state-of-the-art approaches.

Optimal Calculation Method of Distribution Loss in Distribution Systems

  • Rho Dae-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.109-115
    • /
    • 2005
  • Recently, the needs and concerns regarding power loss have been increasing according to energy conservation at the level of the national policies and the business strategies of power utilities. In particular, the issue of power loss is the main factor for determining rates for electrical consumption in the deregulation of the electrical industry. However, because of the lack of management for power loss load factors (LLF) it is difficult to make a calculation for power loss and to make a decision concerning the electric rates. Furthermore, loss factor (k-factor) in Korea, which is of primary significance in the calculation of distribution power loss, has been used as a fixed value of 0.32 since the fiscal year 1973. Therefore, this study presents the statistical calculation methods of the loss factors classified by load types and seasons by using the practical data of 65 primary feeders that have been selected by appropriate procedures. Based on the above, the algorithms and methods, as well as the optimal method of the distribution loss management classified by facilities such as primary feeders, distribution transformers and secondary feeders is presented. The simulation results demonstrate the effectiveness and usefulness of the proposed methods.

Magnetization Loss Characteristic of a Stacked Bi-2223 Conductor (적층 Bi-2223도체의 자화손실 특성)

  • 한형주;류경우;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.46-49
    • /
    • 2002
  • The ac loss is an important issue in the design of superconducting cables and transformers. In these devices the Bi-2223 tapes are usually placed face-to-face In such arrangements ac loss is influenced by adjacent tapes. The effect is investigated by measuring the magnetization loss in the stacked conductor, which consists of various numbers of Bi-2223 tapes. For the stacked conductor in perpendicular field the magnetization loss at low fields is greatly decreased, compared to the loss of the single tape. The loss at high fields is unaffected. This behavior is well described by the slab model.

  • PDF

AC Loss Characteristic in the Fault Current Limiting Elements of a Coil Type (코일형 한류소자의 교류손실 특성)

  • Ryu, Kyung-Woo;Ma, Yong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.370-374
    • /
    • 2005
  • AC loss of a superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in power systems. Therefore, the AC loss characteristics in several fault current limiting elements of a coil type have been investigated experimentally. The test result shows that AC losses measured in the fault current limiting elements depend on arrangement of a voltage lead. The AC loss of a bifilar coil is smallest among the fault current limiting elements of the coil type. The measured AC loss of the bifilar coil is much smaller than that calculated from Norris's elliptical model. However, the loss measured in a meander, which is frequently used in a resistive fault current limiter, agrees well to the theoretical one.

A study on reduction effects of the ground loss in pre-loading (선행하중 재하시 지반손실 감소효과에 관한 연구)

  • Kim, Bong-Yoo;Cho, Nam-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.224-231
    • /
    • 2005
  • The ground excavation causes the deformation of the ground where the neighborhood structure is located. The ground deformation result in the vertical settlement of the neighborhood structure as well as the horizontal displacement of the temporary earth retaining structures. The decreased volume of the soil due to the ground settlement is defined as 'the ground loss quantity' or 'the ground loss'. When excavation is performed nearby existing structures, retaining walls should be designed and constructed to minimize the ground loss. Among various methods for reducing the ground loss, this study introduces the pre-loading method which has been recently developed. The reduction effect of the ground loss by pre-loading has been found to be larger as using a wall with relatively smaller rigidity.

  • PDF