• Title/Summary/Keyword: weighted cell

Search Result 173, Processing Time 0.029 seconds

Diffusion Weighted Imaging Can Distinguish Benign from Malignant Mediastinal Tumors and Mass Lesions: Comparison with Positron Emission Tomography

  • Usuda, Katsuo;Maeda, Sumiko;Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Sagawa, Motoyasu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6469-6475
    • /
    • 2015
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) makes it possible to detect malignant tumors based on the diffusion of water molecules. It is uncertain whether DWI is more useful than positron emission tomography-computed tomography (PET-CT) for distinguishing benign from malignant mediastinal tumors and mass lesions. Materials and Methods: Sixteen malignant mediastinal tumors (thymomas 7, thymic cancers 3, malignant lymphomas 3, malignant germ cell tumors 2, and thymic carcinoid 1) and 12 benign mediastinal tumors or mass lesions were assessed in this study. DWI and PET-CT were performed before biopsy or surgery. Results: The apparent diffusion coefficient (ADC) value ($1.51{\pm}0.46{\times}10^{-3}mm^2/sec$) of malignant mediastinal tumors was significantly lower than that ($2.96{\pm}0.86{\times}10^{-3}mm^2/sec$) of benign mediastinal tumors and mass lesions (P<0.0001). Maximum standardized uptake value (SUVmax) ($11.30{\pm}11.22$) of malignant mediastinal tumors was significantly higher than that ($2.53{\pm}3.92$) of benign mediastinal tumors and mass lesions (P=0.0159). Using the optimal cutoff value (OCV) $2.21{\times}10^{-3}mm^2/sec$ for ADC and 2.93 for SUVmax, the sensitivity (100%) by DWI was not significantly higher than that (93.8%) by PET-CT for malignant mediastinal tumors. The specificity (83.3%) by DWI was not significantly higher than that (66.7%) for benign mediastinal tumors and mass lesions. The accuracy (92.9%) by DWI was not significantly higher than that (82.1%) by PET-CT for mediastinal tumors and mass lesions. Conclusions: There was no significant difference between diagnostic capability of DWI and that of PET-CT for distinguishing mediastinal tumors and mass lesions. DWI is useful in distinguishing benign from malignant mediastinal tumors and mass lesions.

Diagnostic Performance of Whole-Body Diffusion-Weighted Imaging Compared to PET-CT Plus Brain MRI in Staging Clinically Resectable Lung Cancer

  • Usuda, Katsuo;Sagawa, Motoyasu;Maeda, Sumiko;Motono, Nozomu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Takuma Matsui Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Uramoto, Hidetaka
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2775-2780
    • /
    • 2016
  • Background: Precise staging of lung cancer is usually evaluated by PET-CT and brain MRI. Recently, however, whole-body diffusion-weighted magnetic resonance imaging (WB-DWI) has be applied. The aim of this study is to determine whether the diagnostic performance of lung cancer staging by WB-DWI is superior to that of PET-CT+brain MRI. Materials and Methods: PET-CT + brain MRI and WB-DWI were used for lung cancer staging before surgery with 59 adenocarcinomas, 16 squamous cell carcinomas and 6 other carcinomas. Results: PET-CT + brain MRI correctly identified the pathologic N staging in 67 patients (82.7%), with overstaging in 5 (6.2%) and understaging in 9 (11.1%), giving a staging accuracy of 0.827. WB-DWI correctly identified the pathologic N staging in 72 patients (88.9%), with overstaging in 1 (1.2%) and understaging in 8 patients (9.9%), giving a staging accuracy of 0.889. There were no significant differences in accuracies. PET-CT + brain MRI correctly identified the pathologic stages in 56 patients (69.1%), with overstaging in 7 (8.6%) and understaging in 18 (22.2%), giving a staging accuracy of 0.691. WB-DWI correctly identified the pathologic stages in 61 patients (75.3%), with overstaging in 4 (4.9%) and understagings in16(19.7%), giving a staging accuracy of 0.753. There were no significant difference in accuracies. Conclusions: Diagnostic efficacy of WB-DWI for lung cancer staging is equivalent to that of PET-CT + brain MRI.

Magnetic Resonance Imaging Feature of Bacterial Meningitis in a Neonate Hanwoo Calf (한우 송아지에서 세균성 뇌막염의 자기공명영상)

  • Cho, Young-Kwon;Kim, Jin-Won;Kim, Jae-Hoon;Kim, Jae-Hoon;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.650-654
    • /
    • 2009
  • A 1-week-old, male Korean native calf with acute clinical signs of depression, mild diarrhea, ataxia, recumbency and tremor was referred to Chonbuk Veterinary Medical Center of Chonbuk National University. Vision loss and cornea edema were also observed on physical examination. The patient had been deteriorated with nystagumus, strabisumus and opisthtonus. Blood cell count test and blood biochemistry test revealed remarkable leukocytosis, and hypoalbuminemia and increased blood urea nitrogen. No remarkable findings were observed on radiography. On magnetic resonance imaging study, there were enlarge lateral, third, and forth ventricles. The cortical grey and subcortical white matter of left temporal lobe showed hypointense on T1-weighted images and hyperintense on T2-weighted images, and slightly enhanced on contrast-enhanced T1-weighted images. Escherichia coli strain was identified from cerebrospinal fluid sample. Palliative treatment was attempted but the neonatal calve was expired three days after admission. Severe multifocal fibrino-suppurative meningitis with Escherichia coli infection was confirmed histopathologically.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

Solitary Plasmacytoma of the Bone: Radiologic Findings (골단일 형질세포종 : 방사선학적 소견)

  • Yoon, Choon-Sik;Kim, Myung-Joon;Ahn, Chang-Soo;Suh, Jin-Suck;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.2
    • /
    • pp.61-68
    • /
    • 2000
  • Purpose : We examined the patients to evaluate the radiologic findings of solitary plasmacytoma of the bone. Materials and Methods : We retrospectively reviewed radiologic findings of 9 cases with solitary plasmacytoma of the bone (SPB) for recent 5 years, but 2 cases were not included this study due to an abnormal finding of bone marrow and another 2 cases were not included due to an abnormal manifestations of computed tomography (n=1) and MRI (n=1). Results : Among 5 cases, 4 cases had an osteolytic bone destruction and 1 case had an osteosclerotic bone destruction on the plain radiograph. Computed tomography and MRI showed more informations about trabeculated bone destruction and the soft-tissue extension of the lesion comparing to plain radiographs. The MRI finding of SPB in 4 cases showed a relatively high signal intensity on T1-weighted image and intermediate signal intensity on T2-weighted image, on which the signal intensity of the lesion is slightly higher than that of the muscle. One case had an extensive soft-tissue involvement and multiple necrosis, which presented iso to low signal intensity on T1-weighted image and high heterogeneous signal intensity on T2-weighted image. The Gadolinium-enhanced T1-weighted images of 5 cases showed diffusely strong enhancement of the lesion except on the necrosis areas. Conclusion : Computed tomography and MRI may present some characteristics of SPB and demonstrate another foci of plasma cell infiltrates, so these can be helpful for the diagnosis and treatment of SPB.

  • PDF

Influence of O2-Plasma Treatment on the Thin Films of H2 Post-Treated BZO (ZnO:B) (수소 플라즈마 처리된 BZO 박막에 산소 플라즈마의 재처리 조건에 따른 BZO 박막 특성)

  • Yoo, H.J.;Son, C.G;Yoo, J.H.;Park, C.K.;Kim, J.S.;Park, S.G.;Kang, H.D.;Choi, E.H.;Cho, G.S.;Kwon, G.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.275-280
    • /
    • 2010
  • The influence of $O_2$-plasma treatment on $H_2$ post-treated BZO (ZnO:B) thin film using MOCVD (Metal-Organic Chemical Vapor Deposition) are investigated. An $O_2$-plasma treatment of the $H_2$ post-treated BZO thin films resulted in XRD peak of (100), (101) and (110). Also, electrical properties resulted in an increase in sheet resistance and work function. The weighted optical transmittance and haze at 300~1,100 nm of BZO thin films with $O_2$-plasma treatment on the $H_2$ post-treatment show approximately 86% and 15%, respectively.

A Case of Paraneoplastic Limbic Encephalitis Associated with Primary Adenocarcinoma of Lung (비소세포 폐암과 동반된 부수종양성 변연계뇌염 1예)

  • Shin, Hyun Jong;Kim, Hyun Soo;Lim, Keum Nam;Noh, U Seok;Choi, Jung Hye;Kim, In Soon;Lee, Young Yeul;Park, Byeong Bae;Park, Dong Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.4
    • /
    • pp.382-386
    • /
    • 2007
  • Paraneoplastic limbic encephalitis is a rare disorder that is characterized by personality changes, irritability, depression, seizures, memory loss and dementia, and is commonly associated with small cell lung cancer. The cause is unknown but it is believed to be an autoimmune disorder that develops secondary to a carcinomatous process. We report a patient with the clinical feature consistent with limbic encephalitis. A 64-year-old women developed disorientation, memory loss and general weakness. She was diagnosed with NSCLC (adenocarcinoma) with a brain metastasis 1 year earlier and was treated with radiation and chemotherapy. Although the lung mass and brain metastatic lesions had improved, the brain T2-weighted MRI showed high signal intensity in the right temporal region. This lesion consisted of with limbic encephalitis and was negative to the other viral and immune markers. The patient's symptoms did not improve after steroid treatment. Our case demonstrated that a NSCLC (adenocarcinoma) also can be associated with paraneoplastic limbic encephalitis.

Design of a 2.5V 10-bit 300MSPS CMOS D/A Converter (2.5V 10-bit 300MSPS 고성능 CMOS D/A 변환기의 설계)

  • Kwon, Dae-Hoon;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.7
    • /
    • pp.57-65
    • /
    • 2002
  • In this paper, a 2.5V 10-bit 300MSPS CMOS D/A Converter is described. The architecture of the D/A Converter is based on a current steering 8+2 segmented type, which reduces non-linearity error and other secondary effects. In order to achieve a high performance D/A Converter, a novel current cell with a low spurious deglitchnig circuit and a novel inverse thermomeer decoder are proposed. To verify the performance, it is integrated with $0.25{\mu}m$ CMOS 1-poly 5-metal technology. The effective chip area is $1.56mm^2$ and power consumption is about 84mW at 2.5V power supply. The simulation and experimental results show that the glitch energy is 0.9pVsec at fs=100MHz, 15pVsec at fs=300MHz in worst case, respectively. Further, both of INL and DNL are within ${\pm}$1.5LSB, and the SFDR is about 45dB when sampling, frequency, is 300MHz and output frequency is 1MHz.

Design of a Low Power Consumption Accumulator for Parallel Correlators in Spread Spectrum Systems (대역확산 시스템용 병렬 상관기를 위한 저 전력 누적기 설계)

  • Ryoo, Keun-Jang;Chong, Jong-Wha
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.12
    • /
    • pp.27-35
    • /
    • 1999
  • In a typical spread spectrum system, parallel correlator occupies a large fraction of power consumption because of the large number of accumulators in the system. In this paper, a novel accumulator is proposed that can reduce the power consumption in the parallel correlator. The proposed accumulator counts the numbers of 1 of the incoming input data. The counted values are weighted and added together to obtain the final correlation value only at the end of the accumulation. The proposed accumulator has been designed and simulated by CADENCE Verilog-XL and synthesized by SYNOPSYS Design Compiler with $0.6{\mu}m$ standard cell library. Power consumption results have been obtained from EPIC PowerMill simulations. Simulation results are very encouraging. First, the power dissipation is reduced by 22% and the maximum operating frequency is increased by 323%. In addition, the parallel correlator using the proposed accumulators consumed less power than the conventional active parallel correlators by 22%, and less power than the conventional passive correlator by 43%.

  • PDF

An X-ray Diffraction Study of Na, Ag-A Reduced by Hydrogen. Ag$_3\;^+$and Ag$_3\;^{2+}$ Clusters

  • Kim, Yang;Seff, Karl
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.4
    • /
    • pp.135-140
    • /
    • 1984
  • The reduction of vacuum-dehydrated $Na_xAg_{12-x}-A, 0 {\le} x {\le} 9.2$, and its reoxidation by O$_2$, have been studied by X-ray powder diffraction. Also, the structure of $Na_6Na_6-A$ treated with hydrogen at room temperature has been studied by single crystal methods in the cubic space group Pm3m at $24{\circ}C (a = 12.221(2) {\AA})$. The diffraction pattern of dehydrated Ag$_{12}$-A reduced by H$_2$ contains only the (111) and (200) reflections of silver metal, indicationg that the zeolite structure has been lost, but the zeolite's diffraction pattern and structural integrity can be fully restored by oxidation with O$_2$ at 100 or 200${\circ}C$. In contrast, the structures of $Na_xAg_{12-x}-A$, x = 4.5 and 9.2, were not destroyed by treatment with hydrogen. Dehydrated Na$_6Ag_6$-A treated with 50 Torr of hydrogen gas at 24${\circ}C$ for 30 minutes has $6\; Na^+\;and\;1.27\;Ag^+$ ions at 6-ring sites. These $Ag^+ ions are associated with 2.54 Ag${\circ}$ atoms to form 1.27 $Ag_3^+$ clusters per unit cell. Also found were 0.7 $Ag_3^{2+}$ clusters per unit cell near the 8-rings. The structure was refined to the final error indices R$_1$ = 0.134 and R$_2$ (weighted) = 0.147, using 168 independent reflections for which $I_0 >3{\sigma}(I_0)$.