• Title/Summary/Keyword: wedge

Search Result 1,451, Processing Time 0.04 seconds

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

A Study on Dose Distribution using Virtual Wedge in Breast Cancer (유방암 환자에서 가상 쐐기모양 보상체의 선량분포 특성에 대한 연구)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In the radiation therapy for breast cancer patients, wedge shaped compensators are essentially used to achieve appropriate dose distribution because of thickness difference according to breast shapes. Tangential Irradiation technique has usually been applied to radiation therapy for breast cancer patients treated with breast conservative surgery. When a primary beam is incident on wedge shaped compensators from medial direction In tangential irradiation technique, low energy scattered radiation is generated and gives additional dose to the breast surface. As a method to reduced additional dose to breast surface, the use of virtual wedge shaped compensator is possible. Eclipse radiation treatment planning (RTP) systems Installed at our institution have virtual wedge shaped compensator for radiation therapy treatment planning. The dose distributions of 15, 30, 45, 60 degree physical wedges and virtual wedges were measured and compared. Results showed that there was no significant differences In symmetry of $10{\times}10$ field among various wedge angles. When the transmission factor was compared, transmission factor Increased linearly as the wedge angle Increased. These results Indicates that the appilcation of virtual wedge in clinical use is appropriate.

  • PDF

Effects of Medial, Lateral Wedge and Difference of Quadriceps Angle on Vastus Medialis Oblique/Vastus Lateralis Muscle Activity Ratios (내·외측 Wedge와 넙다리네갈래근 각의 차이가 안쪽빗넓은근/가쪽넓은근 비에 미치는 영향)

  • Yoo, Won-Gyu;Lee, Hyun-Ju;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.2
    • /
    • pp.11-19
    • /
    • 2005
  • Patellofemoral pain syndrome (PFPS) is often attributed to malalignment and maltracking of patella within the patellofemoral joint. Most exercise for PFPS has focused on selectively strengthening the vastus medialis oblique muscle (VMO). This study was designed to identify the effect of medial, lateral wedge and difference of Quadriceps angle (Q-angle) on vastus medialis oblique/vastus lateralis muscle (VL) activity ratios. The subjects were twenty young adult males who had not experienced any knee injury. They were asked to perform isometric contraction exercises in three postures using medial and lateral wedge. The EMG activity of the VL and VMO were recorded in three postures by surface electrodes and normalized by %MVC values derived from seated, isometric knee extensions. The normalized EMG activity levels (%MVC) of the VL and VMO for the three postures of the lower extremities were compared using 2-way repeated measures ANOVA with 1 between-subject factor (group), and 1 within-subject factor (wedge). Results of repeated measures of ANOVA's revealed that the medial wedge isometric contraction exercise produced significantly greater EMG activity of VMO/VL ratios in Group I (Q-angle $18^{\circ}$ or less) (p<.05). But, the medial wedge isometric contraction exercise was no significant difference of VMO/VL ratios in Group II (Q-angle $19^{\circ}$ or more) (p>.05). These results have important implications for selective VMO muscle strengthening exercises in PFPS patients.

  • PDF

A Study on the Characteristics of the Acoustic Reflection of the Wedge Shaped Underwater Sound Absorptive Tile (쐐기형 수중음파 흡수타일의 음반사 특성 연구)

  • Kang, Sung-Oug;Hong, Woo-Young;Song, Yeong-Il;Lyu, Ki-Sang;Baek, Chil-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.45-50
    • /
    • 1997
  • Four different wedge angle absorptive tiles were designed and made, and the magnitudes of the reflected acoustic fields by the wedge shaped underwater sound absorptive tiles were measured. The minimum magnitude was found at the angle of 30$^{\circ}$ and the maximum of it was found at the wedge angle of 120$^{\circ}$ from measured the reflected acoustic fields at the front sides of the tiles. The fact that as wedge angle of the absorptive tile increases, the reflection coefficient is increasing is verified. The measured reflected acoustic fields were not dependent on the frequency in the range of 10kHz~30kHz used in this experiment for the same wedge angle tile. The measured reflected acoustic fields at the back sides of the tiles show that they are independent from both type of the absorptive tiles and the frequencies used in the experiments. The measured values and the computed values by the numerical model for the reflected acoustic fields of the wedge shaped absorptive tiles are fairly well comparable with one another.

  • PDF

The Application of Wedge Type Compensation Filter for Uniform Density on the Endoscopic Retrograde Pancreatography (내시경적 역행성 췌관 조영상의 균등한 농도를 위한 적절한 쐐기형 필터의 적용)

  • Son, Soon-Yong;Lee, Hee-Jeong;Lee, Won-Hong;Cho, Cheong-Chan;Ryu, Meung-Sun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.5-9
    • /
    • 2001
  • Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancreatography was performed to 234 patients, and angled wedge filter was used differently. They are $10^{\circ}$ (47), $20^{\circ}$ (45), $30^{\circ}$ (50), and $40^{\circ}$ (50). We also did not use wedge filter to 42 patients. We decided reliance degree in 95%. The statistical difference was p<0.05. The patients' sex rate was 1.8 : 1 between 18 and 87 years old(average age 58 years). Their body girth was 18.71 cm on the average. Of total 234 patients, difference of right and left average density was 0.01 by $30^{\circ}$ wedge filter, -0.08 $40^{\circ}$ wedge filter and 0.27 non-wedge filter. These average values of difference density were very significant statistically, and standard deviation also was close to regular distribution. In conclusion, there is a usefulness of angled wedge filter for increasing diagnostic value of pancreatic duct tall part on the endoscopic retrograde pancreatogram.

  • PDF

The Study of the Mid-sole Wedge of Pronated Group on Maximum Force and Foot Pressure (중족부 Wedge 착용 시 회내 집단의 최대 힘과 족저압력 연구)

  • Lee, Jae-Ik;Lee, Hyo-Taek;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.337-344
    • /
    • 2010
  • This study was conducted on male college students with pronated foot to measure the foot pressure by having them wear three kinds of mid-sole wedge ($0^{\circ}$, $5^{\circ}$, $10^{\circ}$). Maximum force, foot contact area, mean pressure and peak pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding maximum force, there were statistically significant difference in the area 3 of the middle foot(p<.05). Regarding the foot contact area, it appeared broad in the outside area(1, 3, 5) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Mean pressure by foot area decreased in the inside of the foot according to mid-sole wedge, and there was statistically significant difference in the area 2 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Regarding the peak pressure by foot area, the pressure roughly decreased in the inside area(2, 4, 7) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1(p<.05), 2(p<.05) of the rear foot and the area 3 of the middle foot(p<.05).

Application on Pile Under Lateral Load in Multi Layered Ground Using the Strain Wedge Model (변형률 쐐기모델을 이용한 다층지반에서의 횡하중을 받는 말뚝의 적용성 평가)

  • Kim, Hongtaek;Lee, Jungjae;Chung, Jongmin;Yoon, Changjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.159-165
    • /
    • 2009
  • The Strain Wedge Model is useful method for horizontal bearing capacity calculation considering interaction of pile and ground deformation. However, application case of the Strain Wedge Model is rare and the strain wedge model of plenty of verification is needed on multi layered ground in Korea. In this present study, to conduct laboratory model test and numerical analysis for verification of Strain Wedge Model, adapt model that could describe the interaction of pile and ground deformation on multi layered ground. In model test, it was performed to estimate the behavior characteristics on pile under lateral load and to analyze the relationship between load and deformation. In addition, it was fulfilled to measure the skin friction on pile using strain gauge and to decide the ground passive resistance wedge using skin friction. Numerical analysis was performed to verify laboratory model test results.

  • PDF

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.