• 제목/요약/키워드: wave heat sink

검색결과 13건 처리시간 0.021초

전산모사에 의한 웨이브 히트싱크의 열유동 특성 해석 (Heat Flow Analysis in the Newly Developed Wave Heat Sink by Computational Simulation)

  • 이인규;이상웅;강계명;장시영
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.870-875
    • /
    • 2004
  • Heat flow characteristics in the newly developed Wave Heat Sink were analyzed under natural and forced convections by Icepak program using the finite volume method. Temperature distribution and thermal resistance of Wave Heat Sink with/without air vent hole on the top of fin were compared with those of a commercial Al extruded heat sink(Intel Heat Sink). Under the natural convection, the maximum temperature was $45.1^{\circ}C$ in the air vent hole typed Wave Heat Sink, which was superior to that of Intel Heat Sink. The thermal resistance was $2.51^{\circ}C/W$ in the air vent hole typed Wave Heat Sink, and it changed to $2.65^{\circ}C/W\;and\;2.16^{\circ}C/W$ with changes of gravity direction and fin height, respectively. Under the forced convection, the maximum temperature became lower than that under the natural convection. In addition, the thermal resistance lowered in the air vent hole typed Wave Heat Sink with higher fin height and it decreased with increasing the air flux.

전산모사를 이용한 히트싱크의 열 유동 해석 (Heat flow Analysis of Heat Sink Using the Computational Simulation)

  • 임송철;장시영;김현태;이동헌;강계명
    • 한국재료학회지
    • /
    • 제14권7호
    • /
    • pp.522-528
    • /
    • 2004
  • Heat analysis of the plate type and wave type heat sink were carried out by using computational simulation. The heat resistance and air flow of two heat sink models were analysed according to natural and forced convection condition and positions of fan. When a fan was at the position of z-axis and y-axis in forced convection, the heat resistances of plate type heat sink were $0.17^{\circ}C/W$, and $0.28^{\circ}C/W$ respectively. In the case of wave type heat sink, they were $0.18^{\circ}C/W$ and $0.53^{\circ}C/W$. As the air flow velocities were averagely $0.386\;m/s\~3.269\;m/s$, air flow velocity of plate type heat sink was faster than that of wave type. In this experiment, it was observed that the plate type heat sink showed a good ability of heat radiation comparing with wave type one.

CFD를 이용한 히트싱크의 열 해석 (Thermal Analysis of Heat Sink Models using CFD simulation)

  • 임송철;이명호;강계명
    • 한국재료학회지
    • /
    • 제15권12호
    • /
    • pp.829-832
    • /
    • 2005
  • Thermal analysis of new designed heat-sink models was carried out according to the natural ana the forced convection using computational fluid dynamics(CFD). Heat resistance of wave type, top vented wave type and plate type of heat sink was compared with each other As the direction of fin and air flow are vertical(z-axis), it is shown that radiant heat performance of all of heat sinks was superior than other experimental conditions. Especially, the heat resistance of top vented wave heat sink was $0.17^{\circ}C/W$(forced convection) and $0.48^{\circ}C/W$(natural convection). The radiant heat performance of heat sink was increased with increasing the height of fin and the width of fin pitch.

Resistive Grounding Technique of Heat Sink for Reducing Radiation Noise

  • Ahn, Chang-Hoi;Oh, JaeHyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1724-1728
    • /
    • 2014
  • Heat sink has been used to help an electrical device operate in normal temperature condition. But heat sink radiates unwanted electromagnetic wave, which may cause electromagnetic interference problem. A resistance loaded grounding technique is proposed to reduce electromagnetic wave radiation by a heat sink. Numerical simulations are accomplished to find optimal loading resistance. Also electromagnetic fields radiated by from a heat sink are measured and compared with the simulation results. The test results verify the usefulness of the proposed technique.

이중 방열 구조를 갖는 GaAs 건 다이오드 제작 (Fabrication of GaAs Gunn Diodes With A Double Heat Sink)

  • 김미라;이진구;채연식;임현준;최재현;김완주
    • 대한전자공학회논문지SD
    • /
    • 제46권9호
    • /
    • pp.1-6
    • /
    • 2009
  • 본 논문에서는 음극 및 양극으로 동시에 열 방출을 수행할 수 있는 이중 방열 구조의 Gunn 다이오드를 제작하고 음극 방열 구조를 갖는 Gunn 다이오드와 그 특성 차이를 비교하였다. 제작된 다이오드의 DC 특성 측정 결과, 단일 방열 구조의 경우에는 3 V의 문턱전압과 744 mA의 최대 전류 및 4.8 V의 항복 전압 특성을 나타내었고, 이중 방열 구조 다이오드는 2.5 V의 문턱전압, 778 mA의 최대 전류 및 5 V 이상의 항복전압 특성을 나타내었다.

뉴 디자인된 히트싱크의 열 유동 현상 컴퓨터 시뮬레이션 (Computational Simulation of Heat flow phenomena in Newly Designed Heat Sinks)

  • 임송철;최종운;강계명
    • 한국재료학회지
    • /
    • 제14권11호
    • /
    • pp.775-779
    • /
    • 2004
  • For improvement of heat dissipation performance, heat analysis is conducted on the newly designed heat sinks under two convection conditions by using computational fluid dynamics(CFD). Three types of heat sink, plate, wave and top vented wave, are used, and convection conditions are the variations of gravity direction at natural convection and of fan location at forced convection. The results of analysis showed that the heat resistances of top vented wave heat sink were $0.17^{\circ}C$/W(forced convection) and $0.48^{\circ}C$/W(natural convection). In the case of natural convection, gravity direction affected heat flow change, and protection against heat performance was superior in case of z-axis gravity direction. Under the forced convection, all the heat sinks revealed superior thermal characteristics in the fan position of z-axis rather than y-axis. In this study, it was observed that the top vented wave type heat sink showed the best ability of heat radiation comparing with the others.

주거용 15W COB LED 다운라이트 방열판 최적설계에 따른 열적 특성 분석 및 평가 (Thermal Characteristics of the Optimal Design on 15W COB LED Down Light Heat Sink)

  • 권재현;박건준;김태형;김용갑
    • 한국정보통신학회논문지
    • /
    • 제18권2호
    • /
    • pp.401-407
    • /
    • 2014
  • 열에 관한 문제를 해결하기 위해 여러 개의 LED 칩을 1개의 보드에 밀집으로 배열한 COB(Chip On Board)에 관한 관심이 증가하고 있다. LED소자의 온도가 올라갈수록 수명이 감소하고 스펙트럼선의 파장이 본래의 파장보다 장파장 쪽으로 이동하는 적색 이동 현상 및 접합부 온도 상승에 따라 광 출력이 감소되는 큰 문제점이 대두되고 있다. 이러한 열 문제점을 해결하기위해 본 논문에서는 최적의 Fin 두께와 길이를 선정하여 15W급 COB LED 최적의 2차 방열판을 설계하고, 그 설계한 방열판과 15W COB를 패키지하여 Solid Works Flow Simulation을 통한 열적 특성을 분석하여 제작된 15W COB 다운라이트 방열판을 접촉식 온도계를 사용해 열적 특성, 키슬리 2430을 통한 전기적 특성을 분석하였다.

고효율 LED 방열효과 증대를 위한 융합형 Heat Sink 장치 방열 해석 (A Study on Analysis of Complex Heat Sink System for High Efficiency LED Thermal Effect)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제48권2호
    • /
    • pp.12-18
    • /
    • 2011
  • 본 논문은 조명용 LED 모듈과 히트싱크 장치의 방열 특성을 확인하기 위한 수치 시뮬레이션을 하였다. 해석 케이스는 200 W급의 가로등 또는 보안등용 조명장치이며 용도에 따라 장치의 자세가 달라짐을 고려하여 발광면이 정상부를 향하는 경우와 정하부를 향하는 경우로 나누어서 해석이 진행되었고, 또한 발열소자의 체적이 큰 경우와 작은 경우로 나누어 해석하였다. 해석 결과 현재의 히트싱크 형상으로 충분히 LED의 발열량을 외부로 배출시킬 수 있음을 확인하였고, 장치의 자세와 발열소자의 크기에 따라 방열 성능의 차이가 나타남을 조사하였다.

히트싱크 및 히트 스프레더를 이용한 고밀도 발열 전자부품의 방열 구조에 관한 연구 (A Study on Cooling for High Thermal Density Electronics Using Heat Sink and Heat Spreader)

  • 강성욱;김호용;김진천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2286-2291
    • /
    • 2008
  • Some electronics component, which is adopted as components of antenna for radar or satellite system and used for amplifying signals to transmit, is accompanied by very significant heat dissipation levels because of the inefficiencies inherent in radio frequency wave generation. So, proper cooling performance for that system is base requirement for thermal design. On this paper, we applied heat spreading structures to reduce thermal density and find the optimum values of heat sink design factors through theoretically, numerically and evaluated by product test. As the results, the performance of the cooling system shows the propriety of cooling high density heat dissipation electronics components.

  • PDF

초단열 열파동의 전파현상을 활용하는 수소저장합금 열변환 시스템의 성능예측을 위한 수치해석적 연구 (A Numerical Study on a Prediction of Performance of the Metal Hydride Thermal Conversion System through the Propagation Phenomena of Superadiabatic Thermal Waves)

  • 김규정;김관영;채재우
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.572-582
    • /
    • 2001
  • A method of metal-hydride thermal conversion that is an alternative to the traditional method is proposed and investigated. The unit heat pump consists of reactors of two different metal-hydrides are distributed inside parallel channels filled with porous media. The channels are blown through with a heat-transfer agent. Thermal conversion develops as a set of successive heat waves. By a numerical-modeling method it is shown that the maximum thermal effect is attained in synchronous motion of the heat wave and the heat source (or sink) that accompanies the phase transition in the succession of unit metal-hydride pumps. The results are presented in a form convenient for prediction of the thermal and energy efficiency of the proposed thermal-conversion method in real devices.