• Title/Summary/Keyword: waterproof

Search Result 475, Processing Time 0.032 seconds

An Experimental Study about appling non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Self adhesive Rubberized Asphalt sheet to the Roof Structure. (무기질계 탄성 도막재와 자착식 고무 아스팔트 시트를 결합한 지붕구조물 비노출 방수공법에 관한 실험적 연구)

  • Moon, You-Seok;Lee, Sun-Gyu;Song, Je-Yeong;Gwak, Gyu-Seong;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.613-616
    • /
    • 2008
  • This study is about appling non-exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet to the Roof Structure, Because there are a lot of problems in previous methods. So We had the performance tests using waterproofing method which combines two materials, and we analyzed the results. This study showed us very important results. We had bond strength test and tensile test under high, normal and low temperature, and the results were successful. And we also tested for coping with crack and movement. We found that tested materials were safe in those conditions. I think that Non-Exposure waterproofing method which combines the Cement Polymer Modified Waterproof Membrane coating and Selfadhesive Rubberized Asphalt sheet is available to concrete structure.

  • PDF

Study on Adhesive Properties by Hot-air Welding of Polyvinyl Chloride Waterproof Sheet Using used vinyl & used cable in Rural Area (농촌의 폐비닐과 폐전선을 활용한 폴리염화비닐 방수시트의 열풍용착에 의한 접착특성에 관한 연구)

  • Ko, Jin-Soo;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.4
    • /
    • pp.75-81
    • /
    • 2014
  • In this study, we have intended to provide the related construction manuals with technical materials and to reduce the defects in the on-site construction, with reviewing the adhesive properties of joint parts according to change of temperature and speed of hot-air sealer for the products that have been made of polyvinyl chloride(PVC) materials in the single waterproof sheet. The result from the experiment is shown as following. 1) Bond strength was shown as high as the welding speed became slower. For the hot-air welding velocity with 3~6m/min, a stable bond strength has been shown in the range of the hot-air welding temperature with $175{\sim}210^{\circ}C$, while it has been shown in the range of the hot-air welding temperature with $210^{\circ}C$, when the hot-air welding velocity is between 9~12m/min. 2) If the hot-air welding temperature is lower, the adhesive strength has been shown as higher in the section where the hot-air welding velocity is low, while the adhesive strength has been also shown as higher in the section where the velocity is fast as the hot-air welding temperature becomes higher. The highest bond strength has been shown in the velocity with 3m/min for the hot-air welding temperature with $140{\pm}10^{\circ}C$, which is rather low. At $175{\pm}10^{\circ}C$, a high bond strength has been shown in the velocity with 3~6m/min, while the high bond strength has been shown in the velocity with 6~9m/min at $210{\pm}10^{\circ}C$.

FEM Analysis of a Waterproof Seal of Automotive Electrical Connectors (자동차 전장 커넥터 방수 시일의 유한요소해석)

  • Han, JeongJin;Hwang, WonTae;Kim, HoKyung
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • In the case of high-voltage connectors applied to automobiles, waterproofing has become an important issue for the safety of automobiles. In this study, structural analysis is performed on silicone rubber-type waterproof seals used in the voltage connector. For the structural analysis, the tensile properties of the actual rubber seal are evaluated using a miniaturized tensile testing machine. The Mooney-Rivlin material constants of the rubber seal are determined as follows; $D_1=0$, $C_{01}=0.241$, $C_{10}=0.0142$. The analysis shows that the contact pressure at the top of the seal where the seal and male connector are in contact is approximately three times higher than that at the bottom of the seal where the seal and female connector are in contact. It is confirmed that the waterproofing performance of the rubber seal depends on the contact pressure of the seal bottom where the seal and female connector are in contact. The contact pressure for waterproofing is found to be 4.7 bar. The strain concentration of the curved part is attributed to excessive initial tension. Therefore, a redesign is recommended for uniform stress or strain distribution in the curved section of the seal in response to the stress relaxation problem due to permanent deformation.

A Study on the Crack Response and Waterproof Properties of High-Functional Water-Based Acrylic Paints for Exterior Walls (고기능성 외벽용 수성 아크릴계 도료의 균열 대응성 및 방수 특성 평가 연구)

  • Kim, Yong-Ro;Ko, Hyo-Jin;Park, Jin-Sang;Kim, Dong-Bum;Lee, Sang-Wook
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.593-604
    • /
    • 2021
  • In this study, a comparative test was conducted on a specially developed elastic waterproof paint and general water-based paint for the purpose of responding to cracks occurring on the outer wall of concrete structures and improving watertightness. Through the comparative experiment, it was confirmed that the watertightness could be improved by securing the crack shielding property, and it was also confirmed that about 10 times more crack responsiveness was secured compared to general water-based paint. In addition, it was confirmed that the adhesion performance of at least 1.3MPa and resistance to a water permeation pressure of 0.1MPa were possible, confirming that stability was secured from a waterproofing perspective.

Optimization Design of a Waterproof Seal Cross-Section of Automotive Electrical Connectors (자동차 전장 커넥터 방수시일 단면의 최적설계)

  • Kang, KyuTae;Lee, ChaeEun;Kim, HoKyung
    • Tribology and Lubricants
    • /
    • v.37 no.6
    • /
    • pp.224-231
    • /
    • 2021
  • Recently, the waterproofing performance of high-voltage connectors in automotive vehicles has attracted increased interest. In this study, an optimal cross-sectional shape was derived to obtain uniform contact pressure and strain by considering stress relaxation problems caused by initial tension when mounting a seal. A high strain of 52.1 was distributed in the round region, owing to excessive initial tension. The finite element method (FEM) analysis indicated that the strain corresponding to the optimal initial tensile was 11. We adopted six design factors to optimize the seal cross-section and three factors as the main design factors. An orthogonal arrangement table was prepared using Minitab. FEM analyses of 16 study models were conducted to determine the optimized model. The contact pressure of the optimization model is the most evenly distributed while satisfying the waterproof performance of 0.47 MPa. Compared to the initial model, the difference in strain decreases from 35.5% to 19.6%. Finally, the derived cross-sectional shape can reduce the strain of the round region by 33.8% and the differences in the contact pressure at the upper and lower surfaces by 42% and 76%, respectively.

Comparison of Mechanical Properties of Electrospun Nanofiber Web Layered Systems and Conventional Breathable Waterproof Fabrics (전기방사한 나노섬유 웹 처리소재와 상용 투습방수소재의 역학적 특성 비교)

  • Youn, Bo-Ram;Lee, Seung-Sin
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.391-402
    • /
    • 2010
  • In this study, breathable waterproof materials were prepared by electrospinning. Five kinds of electrospun nanofiber web layered systems with different levels of nanofiber web density, as well as different substrates and layer structures were fabricated, and their mechanical properties (tensile, bending, shear, compression, surface, and thickness & weight) were measured by the KES-FB system and compared with those of conventional breathable waterproof fabrics (densely woven fabric, PTFE laminated fabric and PU coated fabric). The KES-FB measurements demonstrate that the lab-scale nanofiber web layered systems are more flexible and fuller than commercial nanofiber web layered systems, which have a more compact structure than the lab-scale nanofiber web layered systems. Densely woven fabrics and lab-scale nanofiber web layered systems showed lower values of tensile linearity (LT), bending stiffness (B), and shear stiffness (G) than those of PU coated and PTFE laminated fabric. These results indicate that they are more flexible and have less resistance to the shearing movement, corresponding to a more pliable material having a better drape, than PU coated fabrics and PTFE laminated fabrics.

  • PDF

Optimum design of injection mold heater for uniform curing of LSR seal for waterproof connector (방수 커넥터용 LSR Seal의 균일 경화를 위한 사출 금형 히터의 최적 설계)

  • Song, Min-Jae;Cha, Baeg-Soon;Hong, Seok-Kwan;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.310-315
    • /
    • 2017
  • Automotive waterproof connectors are highly functional parts that must be air-tight in a complex environment. In the LSR multi-cavity injection molding process for manufacturing waterproof connectors, it is important to maintain a uniform curing temperature between the cavities in order to obtain a quality product. For this purpose, we designed the capacity of the cartridge heater differently for each position, and then linked the heat transfer analysis and optimization module to obtain the optimal cartridge heater capacity. As a result of the optimization analysis, the temperature deviation between cavities was decreased from $13.1^{\circ}C$ to $8.1^{\circ}C$ compared with the case in which constant heater capacity was applied, so that the design criterion could be satisfied within a temperature deviation of $10^{\circ}C$ for uniform curing. This study suggests that this method can be applied efficiently to the design of a large area multi-cavity LSR mold heater.

Synthesis and Characterization of Fluorine-induced, UV Curable Urethane Acrylate Oligomers (불소가 도입된 광경화형 우레탄 아크릴레이트 올리고머의 합성 및 특성분석)

  • Won, Jong-Woo;Park, Jung-Hyun;Kim, Ju-Yeol;Yoon, Yoo-Jung;Jang, Ki-deog;Park, Myung-Chul;Chun, Jae Hwan;Hwang, Jin-Sang
    • Journal of Adhesion and Interface
    • /
    • v.18 no.3
    • /
    • pp.127-133
    • /
    • 2017
  • In this study, to develop the adhesives with improved waterproof properties for display application, UV-curable urethane acrylate oligomers containing a fluorine moiety were synthesized from hydrogenated polybutadiene diol (HLBH-P2000), perfluoropolyether diol (HTPFPE), isophorone diisocyanate (IPDI) and 2-hydroxyethyl acrylate (HEA). The properties which were related waterproof performance such as contact angle, surface energy and water vapor transmission ratio (WVTR) of synthesized fluorine induced urethane acrylate oligomers were measured. As the HTPFPE content increased, the contact angle also increased from 97.9 degree to 104.4 degree. The surface energy and WVTR decreased as the HTPFPE content increased. The adhesion strength also decreased according to the HTPFPE content increased, and the adhesion strength reduction had greatly increased as the HTPFPE content increased. The findings of this study will be beneficial for developing waterproofing adhesives in the field of display which has recently been a waterproof issue.

Geophysical Investigation of the change of geological environment of the Nanjido Landfill due to the Stabilization Process (난지도 매립장의 안정화에 따른 지질환경 변화 조사를 위한 지구물리 탐사)

  • Lee, Kie-Hwa;Kwon, Byung-Doo;Rim, Hyoung-Rae;Yang, Jun-Mo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.113-126
    • /
    • 2000
  • We have conducted multiple geophysical surveys to investigate the geoenvironmental change of the Nanjido Landfill due to the stabilization process. Geophyscial surveys are comprized of gravity, magnetic, dipole-dipole electrical and SP methods. Due to the field conditions, surveys were conducted on the top surface of the landfill no.2 and southern border areas in front of landfills. The gravity anomalies obtained on the top surface of the landfill no.2 in 1999 show that the gradient of the anomaly on the central area is decreasing in comparison with that observed four years ago. The complexity of magnetic anomaly pattern it also decreasing. These facts suggest that the stabilization work of the Nanjido landfill makes some progress by compaction process due to repetitive subsidence and refilling. The dipole-dipole electrical resistivity and SP data obtained on the outside of the waterproof wall at the landfill no.1 were severely affected by unsatisfactory surface conditions. On the other hand, the dipole-dipole electrical resistivity profiles obtained on the inside and outside parts of the waterproof wall at the landfill no.2 show the blocking effect of leachate flow by the waterproof wall. Few SP anomalies are observed on the top and side surfaces of the landfill no.2, but SP anomalies obtained on the base area inside the waterproof wall strongly reflect the effect of leachate collecting wells.

  • PDF

Drainage system for leakage treatment of cement concrete structure in underground (콘크리트 지하구조물 누수 처리를 위한 유도배수시스템)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.573-585
    • /
    • 2019
  • The objective of this study is to propose the drainage system that has been improved the workability, waterproofing and drainage performance to treat the leakage from the cement concrete structures in underground. It is improved that the pipe for conveying ground leak in the existing drainage system had the problem in workability and waterproof. The drainage systems with the improved pipe for conveying ground leak were constructed in conventional concrete lining tunnels to evaluate the workability, waterproofing and drainage. The waterproof and the drainage performance of the drainage system was evaluated by injecting 1,000 ml of red water in the back of the drainage system at 3 weeks, 6 weeks, 9 weeks, 11 weeks, 14 weeks, 17 weeks and 23 weeks. During 6 months of field performance test, the average daily temperature of the tunnel site was measured from $-12.4^{\circ}C$ to $19.7^{\circ}C$. The daily minimum temperature was $-17.2^{\circ}C$ and the daily maximum temperature was $26.7^{\circ}C$. There was no problem in waterproof and drainage performance on the pipe for conveying ground leak and the drainage system during 6 months for field performance test. It is concluded that the improved drainage system can be applied to various cement concrete underground structures where leakage occurs, and has little seasonal effect.