• Title/Summary/Keyword: water treatment chemicals

Search Result 281, Processing Time 0.026 seconds

A review on status of organic micropollutants from sewage effluent and their management strategies (하수 유래 미량오염물질 현황과 관리 방안 고찰)

  • Choi, Sangki;Lee, Woongbae;Kim, Young-Mo;Hong, Seok-Won;Son, Heejong;Lee, Yunho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

A Basic Study for Tasted and Odors Treatment and Optimum Chemical Feed in Existing Water Treatment Processes (기존 정수처리공정에서 이취미처리 및 최적 약품투입을 위한 기초연구)

  • Lim, Bong-Su;Bae, Byung-Uk;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.94-102
    • /
    • 1996
  • This study was accomplished to get the basic data for the optimum chemical feed, evaluating interference between tastes and odors chemicals and coagulants in existing water treatment processes. During the tastes and odors occurs at D intaking tower area in 1995, PAC(Powdered Activated Carbon) feed with coagulants was PAC feed only and with coagulant simultaneously were appeared TON removal efficiency about 84%-87% within 20 min reaction time, but feed with time intervals was about 98% TON removal efficiency. Therefore in the case of PAC feed with coagulant, it is effective to feed coagulant on some time intervals in removing tastes and odors. It is not effective to feed PAC with chlorine dioxide($ClO_2$) or chlorine simultaneously in removing tastes and odors, because these chemicals were reduced the adsorption capacity of PAC.

  • PDF

An Application of Toxicity Test to Water Management and Water Treatment (수질관리와 수처리에의 독성시험의 응용)

  • Kim, Berm-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2005
  • In this research, we tried to develop the application method to water management and treatment using toxicity test method. When we measure the toxicity of environmental samples, we have to decide whether we take some countermeasures to reduce the toxicity or not. The first issue is how to set these action levels in each bioassays. A new idea was attempted to authorize indirect approach of each bioassays through the response characteristics against mixture of chemicals in water quality standard. The significant response in the cell-growth-inhibition bioassay was detected for standards-mixture(STDs). For acute toxicity assay, STDs-based implicit correlation between risks to humans and bioassay data showed a rational approach to set action levels in practical management. A simple model was proposed to describe and predict the changes in the total toxicity based on the concentrations of toxic-controlling chemicals during the ozonation of landfill leachates. On the basis of this simple model, toxicity reduction was predicted for pre-aggregation treatment before ozonation and ozone concentration during the ozonation. The method proposed in this study would be useful in optimizing water treatment processes and their running conditions in terms of the toxicity reduction efficacy.

Risk Assessment of Drinking Water Pollutants (다중이용시설에서의 먹는물 위해성 평가)

  • Back, Young Maan;Chung, Yong;Park, Je Chul;Kim, Hyung Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1107-1108
    • /
    • 2006
  • As expanding municipal and industrial areas since started the economic development plan in earnest in 1970's, the water resource, mainly river surface water has been seriously polluted. Nevertheless, being upgraded in their treatment technologies for the drinking water, the safety has been issued one of crucially social problem in Korea. The water authorities has tried to improve the quality such as amending the drinking water quality standard to be monitored; hazardous chemicals and microorganis have been added and now 55 items, before 47 items, since in 2002. The Water Authorities of Seoul, the capital city of Korea, planned to assess the safty of drinking water quality after amended the standard. This study was conducted to assess the risk due to polluted chemicals including 21 heavy metals, VOCs, pesticides, PAHs, DBPs and organic chemicals among the regulated items. The risk assessment were undertaken hazard identification, exposure assessment, dose-response assessment and risk characterization. For the exposoure assessment, tap water, bottled water and purified water were sampled and analyzed in February, 2004. Risk characterization of detected chemicals was categorized into carcinogenecity and noncarcinogenecity, and estimated the excess of carcinogens and compapared with the reference dose (RfD) of noncarcinogenns. The excess risk of carcinogens from samples were considered comparatively in the acceptable levels; $10^{-6}$ for cancer risk and hazard quotient (HQ) 1.0 for noncancer risk. The deteced levels were estimated in $10^{-5}{\sim}10^{-6}$ of cancer risk and below 1.0 of HQ of noncancer risk. While three kinds of water were determined within the acceptal levels, DBPs were detected in tap water and purified were and some undesireable chemicals such as more fluoride detected rather than the quality stanadard. For the drinking water safety, it shoud be continuously monitored, assessed and managed as well risk communiction between the authoritis and public.

Preparation of PAC for Water Treatment Chemicals Using Waste Aluminum Dross (알루미늄 폐드로스로부터 수처리응집제용 염화알루미늄 제조)

  • Park, Hyung-Kyu;Choi, Young-Yoon;Eom, Hyoung-Choon;Bae, Dong-Su
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.52-56
    • /
    • 2006
  • Waste aluminum dross was leached with hydrochloric acid to prepare PAC, poly aluminium chloride, used as water treatment chemicals. Metallic aluminum remained in the waste aluminum dross was dissolved into the hydrochloric acid solution. The solution could be used as PAC after adjusting the required alumina concentration and the basicity. Comparing to the conventional method far preparation of PAC using aluminum hydroxide, material cost could be saved in this method. Also, there is an additional merit in view of recycling of the waste aluminum dross by reducing the amount of waste dross to be landfilled.

A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers (R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구)

  • JUNG, DA-WOON;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling - (자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 -)

  • Kim, Jun-Hyun;Jang, Jung-Woo;Kim, Jin-Ho;Park, Kwang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.93-104
    • /
    • 2020
  • As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.

Biodegradability Index Development Based on Aerobic Biodegradation, Anaerobic Biodegradation, and Toxicity Test (호기성 분해, 혐기성 분해 및 독성을 고려한 생분해도 지표 개발)

  • Yoo, Kyu-Seon;Shin, Hang-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.603-608
    • /
    • 2010
  • More than 8 millions of chemical have been used for human activities and lots of chemicals can not be degraded by microbial activities in this world. To show the biodegradability of a chemical, biodegradability index (B.I.) is suggested using aerobic biodegradability by $BOD_5$/COD, anaerobic biodegradability by methane potential (M.P.) and toxicity by the luminiscent bacteria. In this study, PVA (polyvinyl alcohol), HEC (hydroxy ethyl cellulose), 2,4,6-TCP (tri-chloro phenol) and 2,4-DCP (di-chloro phenol) are used for test chemicals. Though they show little toxicity, PAV and HEC have low B.I. because they are polymers having high molecular weight. That means that there are no bacteria that has enzyme to degrade polymer molecules. Also, anaerobic treatment is suggested better than aerobic treatment from B.I. 2,4,6-TCP and 2,4-DCP show high toxicity and have low B.I. Their low biodegradabilities seem to be originated from their toxicities. If B.I. is used in wastewater treatment, better treatment process can be suggested and finally it can lead our society to make more environment-friendly chemicals.

A Study of Potable Water Disinfection for National Health (수돗물 살균제가 국민보건에 미치는 영향에 관한 연구)

  • Shin Soo Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 1996
  • Disinfection is a very important process in water plant on account of our surface water usage. Particularly. the rainfall of Korea is concentrated in summer time. it is almost carried away to ocean before our utilization as water resource. To overcome the unbalance of water resource, artificial dams and reservoirs are constructed. According to such storage of water to aggravate water pollution and make the increase of water cleaning chemicals. Chlorine, as a main traditional chemical for water treatment. is focused on account of THMS formation in recent days. In this paper. the data of a water plant located in Seoul is adopted as the foundation of water quality analysis and introduce the substitute chemicals to supplement the harmful formation. additionally. Conclusions are summarized as follows: 1. The water quality of water resource is the worst in summer time and the supply of cleaning chemical is inevitably increased on account of general bacteria increase. 2. Chlorine, as a main chemical for water cleaning, formed the cancer-causing organic THMS with water molecules. 3. One of substitute chemical. chlorine dioxids suppress the formation of THMS comparing with the case of chlorine only. Therefore. the continuous research of substitute chemicals should be activated. 4. As the supply of disinfected clean water concerned with the citizen sanitary, the cultivation of professionals and academic conference must be needed on the basis of nation

  • PDF

A Study on the Management of Harzardous Chemlcals from the Middle School Science Class (중학교 과학실에서 사용되는 유해 화학물질의 관리방안에 관한 조사 연구)

  • Kim, Sang-ok;Chung, Yong
    • Hwankyungkyoyuk
    • /
    • v.2 no.1
    • /
    • pp.69-83
    • /
    • 1991
  • The management and disposal of harzardous chemicals from the middle school science class was studied for the safety of student and for the protection of the environment. This study was undertaken by analysis of 5 kinks of current middle school science text book and questionnaire survey, and reviewed on the recommended methods for the disposal of harzardous chemical wastes from science class. There are 237 chemicals determined in the middle school science text books and 87 among them actually used in middle school science laboratory. 51 chemicals are classified as harzardous ones and 49 highly hazardous according to the 'Law of Toxic Chemicals management'. 116 chemicals are defined as water pollutants and 10 are highly hazardous water pollutants according to the 'Water Quality Control Law' as well are 91 chemicals as air pollutants and 19 are highly hazardous air pollutants according to the 'Air Quality Control Law' Questionnaire survey results the identification of toxic chemicals, need for education, awareness of toxic effects and current problems in the management. Disposal of toxic chemicals in middle school science class has been undertaken without any treatment, which could be caused of environmental pollution. Most of science teacher wanted to have opportunities to attend supplement courses for the management and disposal of chemicals for the safety and environmental protection. Simple and applicable methods for the management and disposal of chemicals at middle school science level should be strongly recommended to be installed.

  • PDF