DOI QR코드

DOI QR Code

자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 -

A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling -

  • 김준현 (인천광역시 상수도사업본부 수질연구소) ;
  • 장정우 ((주)에코니티) ;
  • 김진호 ((주)에코니티) ;
  • 박광덕 (한국건설기술연구원 국토보전연구본부)
  • 투고 : 2019.10.15
  • 심사 : 2020.02.13
  • 발행 : 2020.04.15

초록

As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.

키워드

참고문헌

  1. Bae, B.U., Park, J.H., Jeong, Y.G., and Lim, K.H. (2003). Thickening characteristics of water treatment sludge as a function of the type of raw water, Korean Soc. Environ. Eng., 25(11), 1400-1404.
  2. Bae, B.U., Her K., Joo, D.S., Jeong, Y.G., Kim, Y.I., and Ha C.W. (2007). A new program to design residual treatment trains at water treatment plants, Korean Soc. Environ. Eng., 29(3), 277-282.
  3. Beicha, A., Zaamouche, R. and Sulaiman, N.M. (2009). Dynamic ultrafiltration model based on concentration polarization-cake layer interplay, Desalination, 242(1-3), 138-148. https://doi.org/10.1016/j.desal.2008.03.037
  4. Brugger, A. (2000). Reuse of filter backwash water using ultrafiltraion technology, Filtr. Sep., 27(1), 22-26.
  5. Department of Environment. (2009). Water quality and water ecosystem preservation of in Laws, Enforcement Regulations, attached form 10.
  6. Dotremont, C., Molenberghs, B., Doyen, W., Bielen, P., and Huysman, K. (1999). The recovery of backwash water from sand filters by ultrafiltration, Desalination, 126, 87-97. https://doi.org/10.1016/S0011-9164(99)00158-7
  7. Eom, J.Y., Kim, K.Y., Kim, Y.H., Song, J.S., Kim, H.S., Han, M.A., and Yang, H.S. (2008). A study about applicability of treatment for backwash water using tubular membrane system with dead-end operation mode, J. Korean Soc. Water Wastewater, 22(4), 437-444.
  8. E-WATER Preoject. (2005). Final report, Japan Water Technology Institue Center.
  9. Kim, Y.H., Kim, K.Y., Kim, J.H., Lee, Y.S., Lee, E.J., Eom, J.Y., Kim, H.S., and Hwang, S.J. (2009). A study about applicability of treatment for water treatment residual sludge using crossflow tubular membrane system, J. Korean Soc. Water Wastewater, 23(4), 499-505.
  10. Lee, Y.H., No, E.S., and Han, M.W. (2011). Technology inspection reports of Nam-dong water treatment plant, Vi-126-vi-148.
  11. Ministry of Environment. (2018). 2017 Statics of waterworks.
  12. Moon, W.J., and Moon, Y.T. (2004). "Diagnosis through estimation on the capacities of water treatment plant residuals treatment facilities", Journal of Korean Society of Environmental Engineers spring conference 2004, Korea.
  13. Water Journal. (2009). http://www.waterindustry.co.kr/domestic/domestic02.php?ptype=view&code=domestic02&idx=8178 (July 22, 2019).
  14. Willemse, R.J.N. and Brekwoort, Y. (1999). Full-scale recycling of backwash water from sand filters using dead-end membrane filration, Water Res., 33(15), 3379-3385. https://doi.org/10.1016/S0043-1354(99)00036-6