• Title/Summary/Keyword: water transmission

Search Result 988, Processing Time 0.027 seconds

Study on Underwater Optical Communication System for Video Transmission (영상통신용 수중광통신 시스템 연구)

  • Son, Hyun-Joong;Kang, Jin-Il;Nhat, Thieu Quang Minh;Kim, Seo Kang;Choi, Hyeung-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.143-150
    • /
    • 2018
  • In this study, we designed and developed an underwater LED communication system composed of an LED and a photo sensor. In addition, we experimented with video data transmission in a water tank. Two communication modules were installed in the 3 m water tank, and the image data transmission test was successfully performed at a rate of 20 frames per second(FPS), image resolution of $480{\times}272$, and data communication speed of 4 Mbps.

Numerical Study of Transmisson and Reflection Coefficients of a BBDB-Type Floating Breakwater (공기챔버형 부소파제의 투과 및 산란파 해석)

  • Hong, Do-Chun;Kim, Hyeon-Ju;Hong, Sa-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.1 s.139
    • /
    • pp.18-23
    • /
    • 2005
  • The transmission and reflection coefficiencies of a BBDB-type floating breakwater in water of finite depth are studied taking account of fluctuating air pressure in the air chamber. The wave potential is calculated by a hybrid integral equation consisting of a Green integral equations associated with the Rankiue Green function inside the BBDB and the Kelvin Green function outside. The transmission and reflection coefficients of the breakwater are obtained directly from the potential solution in the outer region.

Investigating coating material and conditions for rehabilitation of water transmission pipe using a robotic system (자동화 장비를 이용한 대형 상수관로 갱생을 위한 코팅재료 선정 및 방법에 관한 연구)

  • kim, Jinwon;Kim, Donghyun;Lee, Younggun;Lee, Sewan;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.725-736
    • /
    • 2016
  • There is a growing concern on the improvement of water distribution pipeline for multi-regional water supply system in Korea along with its aging infrastructure. Rehabilitation of large diameter pipeline is more efficient in cost and time compared to replacement with trenching. The procedure for rehabilitation are diagnosis, cleaning, spraying coating material, and final inspection. The internal state of pipeline was carefully diagnosed and got C grade, which required rehabilitation. We found that 17,274,787,000 Korean won could be saved after pipe surface coating because of increased C coefficient of Hazen-Williams equation. Optimal coating material was D polyurea. We also found optimal distance between spraying nozzle and pipe wall to be 70 - 80 cm, which were critical factors for coating quality. This study also illustrated the time for spray drying to be more than 30 min. These results could be used in the quality control process during rehabilitation of aged pipelines.

The development of industrial secure L2 switch and introduction example for management and security improvement of supervisory control network in purification plant (정수장 감시제어망의 관리와 보안개선을 위한 산업용 보안 L2스위치 개발 및 적용사례)

  • Kim, Yunha;Yu, Chool;Oh, Eun;Kim, Chanmoon;Park, Ikdong;Kim, Yongseong;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.329-339
    • /
    • 2019
  • Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.

Water Vapor Transmission for T800/AD6005 Based Composite Motor Case (T800/AD6005계 복합재 연소관의 습기 투과에 관한 연구)

  • 박명규;류백능;최영보;도영대
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.50-58
    • /
    • 1998
  • Water vapor transmission was tested in water bath controlled by $20^{\cire}C$, 90%RH for T800/AD6005 based composite motor case which made by filament winding method. We detected internal relative humidity of composite motor case by inserting the humidity detector through the head of motor case for the study of humidity transmission through the wall of composite motor case. We found out that this composite material appears the water vapor flux of 2.88${\times}$$10^{-9}$g/$\textrm{m}^2$sec and diffusivity of 7.98${\times}$$10^{-7}$$\textrm{mm}^2$/sec at $20^{\cire}C$, 90%RH water vapor condition.

  • PDF

Comparative evaluation of water vapor transmission rate of PVA/Dextran blended hydrogel using European Pharmacopiea and Japanese Industrial Standards method (유럽 약전과 일본 산업기준 규격 방식에 의한 폴리비닐 알코올 및 덱스트란 함유 하이드로겔의 투습률 비교평가)

  • Choi, Han-Gon;Hwang, Ma-Ro;Oh, Dong-Hoon;Li, Dong-Xun;Kim, Jong-Oh;Lee, Jeong-Hoon;Woo, Jong-Soo;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.2
    • /
    • pp.93-95
    • /
    • 2009
  • To compare the water vapor transmission rate (WVTR) of PVA/Dextran blended hydrogel obtained by European Pharmacopiea (EP) and Japanese Industrial Standards 1099 (JIS) method, the hydrogels with various PVA/Dextran rates were prepared and their WVTR values were then checked. As dextran in the hydrogel was increased, the WVTR of hydrogel was increased. The WVTR of hydrogels were 660-1500 and $730-1900\;g/m^2$-day in EP and JIS method, respectively. There were no significant differences between the WVTRs of the hydrogels obtained by EP and those obtained by JIS method. Thus, JIS method was recommended as a WVTR method of hydrogel due to relatively simpler and shorter time.

Ytterbium Test for Water Vapor Transmission Rate Measurement of Passivation Film for Organic Electronics (유기 전자 소자의 봉지막 투습도 분석을 위한 Ytterbium Test)

  • Lim, Young-Ji;Lee, Jae-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.29 no.4
    • /
    • pp.484-487
    • /
    • 2018
  • In this paper, the optical and electrical properties of ytterbium films were studied for water vapor transmission rate (WVTR) analysis of encapsulation films used in organic electronic devices. Ytterbium thin films show a wide range of light transmittance (70-10%) and resistivity ($6.0-0.16m{\Omega}{\cdot}cm$) depending on various film thicknesses (20-100 nm). The Yb thin films were oxidized with moisture and its transmittance and resistance changed in real time. As a result, the WVTR of parylene and aluminum nitride (AlN) laminated thin encapsulation film was measured to be $4.3{\times}10^{-3}g/m^2{\cdot}day$ with the 25 nm thick ytterbium thin film.

Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound (자켓 컴파운드용 절연재의 수증기투과 및 절연파괴 특성)

  • Song, Jae-Joo;Han, Jae-Hong;Song, IL-Keun;Han, Yong-Hee;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB (Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC (Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE > LLDPE ≒ MDPE > LDPE and WVT ratio was HDPE < LLDPE < MDPE < LLDPE ≒ LDPE${\ll}$PVC. WVT of PVC using for jacket showed characteristic 15 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials

  • PDF

A Study on the Telemetric Measuring System of the Underwater Information (수중정보의 원격계측시스템에 관한 연구)

  • 신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.7-11
    • /
    • 1988
  • This Paper describes technique for the design of system for telemetering the water temperature at sea. This telemetering device adopts FM-FM system, and its main carrier wave is 146.2MHz. The transmission power is about 1W, and the available distance of transmission is 2km. The telemetering time for the transmission and pause is controlled automatically by the CMOS programmable timer. The water temperature is measured by the electronic thermometer, it is varied by V-F converter which is built to a linear voltage controlled oscillator. The results of the experiment at the place where the receiver is off 2km from the transmitter, the water temperature measured with the mercury thermometer well agree with that of the telemetering device.

  • PDF