• 제목/요약/키워드: water quality degradation

검색결과 228건 처리시간 0.029초

상수관망에서 생물막에 의한 Haloacetic Acids 생물분해 특성 평가 (Evaluation of Biodegradation Characteristics of Haloacetic Acids by a Biofilm in a Drinking Water Distribution System)

  • 손희종;김도환;한영립;최영익
    • 한국환경과학회지
    • /
    • 제23권9호
    • /
    • pp.1635-1642
    • /
    • 2014
  • Haloacetic acids (HAAs) concentrations have been observed to decreased at drinking water distribution system extremities. This decrease is associated with microbiological degradation by pipe wall biofilm. The objective of this study was to evaluate HAAs degradation in a drinking water system in the presence of a biofilm and to identify the factors that influence this degradation. Degradation of monochloroacetic acid (MCAA), dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) was observed in a simulated distribution system. The results obtained showed that different parameters came into play simultaneously in the degradation of HAAs, including retention time, water temperature, biomass, and composition of organic matter. Seasonal variations had a major effect on HAAs degradation and biomass quantity (ATP concentration) was lower by 25% in the winter compared with the summer.

자동차용 head lamp의 수밀원인 분석 (Failure analysis on the phenomenon of water condensing of automotive head lamp assembly)

  • 조영진;전종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1349-1354
    • /
    • 2008
  • In this study, we try to find the root cause of water condensing failures in a headlamp using chemical and mechanical analysis. Through the surface inspection by OM, SEM and CT, it was found that water infiltrate into the headlamp through hotmelt adhesive debonding part caused by adhesion force degradation and poor quality. IR spectra shows that adhesion force degradation are characterized by increase of some functional group(1742, 1710, 1649, 1016). Through the ESPI measurement, it is turned out that bonding structural change by thermal expansion and degradation of adhesive can be the cause of void generation. So it is recommended that cooling passage and the bonding part should be redesigned to give a guarantee of less thermal stress and high adhesion quality.

  • PDF

오존과 광촉매를 이용한 Geosmin 제거 및 부산물 생성에 관한 연구 (A Study on removal of Geosmin by Ozonation and Photocatalysis and Generation of by-products)

  • 김영웅;손희종;유명호;김성윤;김철
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.445-457
    • /
    • 2000
  • This study was carried out comparing with ozone oxidation and photocatalytic degradation for removal of geosmin. In the change of pH, Ozonation, UV-Germicidal lamp and Halogen lamp irradiation and Halogen $lamp/TiO_2$ Powder was very slowly changing, but UV-Germicidal $lamp/TiO_2$ Powder was rapidly changed from 7.0 to 7.7 until 300min of irradiation time, and varied a little after. Geosmin degradation ratio was as following, UV-Germicidal $lamp/TiO_2$ $Powder(200mg/L){\geq}O_3$ > UV-Germicidal $lamp/TiO_2$ $Pw(100mg/L)$ > UV-Germicidal lamp > Halogen lamp. The result of investigation of generated by-products were 3-Heptanone, two sort of aldehydes and three sort of alcohols by ozonation. But It was not generated by photocatalytic degradation.

  • PDF

수질 악화로 인한 후생변화의 추정 (Estimation of Welfare Change from Water Quality Degradation)

  • 전철현;이충선;신효중
    • 환경정책연구
    • /
    • 제9권2호
    • /
    • pp.135-155
    • /
    • 2010
  • 본 논문의 목적은 강릉 남대천처럼 시민들과 매우 밀접한 관계에 있는 자연환경의 질이 악화될 경우 시민들의 후생에 얼마나 큰 영향을 미치는지를 조건부가치측정법을 통하여 평가하는데 있다. 분석 결과, 강릉 남대천은 상수원의 제공뿐만 아니라, 공익적 기능, 생태적 기능, 물놀이, 휴양 및 심미적 만족감을 제공하는 장소로서 중요하다고 인식되고 있으며 강릉 남대천의 수질을 개선하기 위한 총 지불의사액은 가구당 연간 117,040원이 도출되었다. 먼저 수질개선 부담금의 지불에 가구당 연평균 약 87,502원으로 나타났고, 자원봉사에 대한 기회비용 측면에서는 연평균 29,538원으로 나타났다. 위의 결과를 근거로 강릉시 전체로 확대할 경우 수질 악화에 의한 간접적인 후생변화는 연간 약 270억원으로 산출되었다. 이처럼 수질 악화에 의한 후생변화는 매우 크다고 볼 수 있다. 따라서 자연환경은 비가역적인 특징을 가지면서 한번 파괴되면 복원되는데 많은 시간과 비용이 수반되기 때문에, 자연환경의 변화는 궁극적으로 인간에게 영향을 미치게 된다. 그러므로 의사결정자들은 자연환경과 관련된 정책을 수립할 때 시장에서 평가되는 부분뿐만 아니라 시장에서 거래가 되지 않는 간접적인 부분까지도 충분히 고려하여야 정책의 효율성과 후생 증대의 목표를 동시에 달성할 수 있다.

  • PDF

석문지구 간척지 담수호 수질변화 (Water Quality of Sukmoon Lake Developed by Sea-Dike Construction)

  • 윤광식;인순한
    • 한국농촌계획학회:학술대회논문집
    • /
    • 한국농촌계획학회 1998년도 임시총회 및 추계 학술논문발표회
    • /
    • pp.16-18
    • /
    • 1998
  • Fresh water lake was developed as a result of tidal land reclamation of the Sukmoon area. Water quality of lake has been monitored before and after sea-dike construction. Water quality degradation has been observed after Sukmoon sea-dike construction. In this paper observed water quality of the Sukmoon lake is presented and possible measures to improve water quality are also discussed.

  • PDF

배합수량 변동에 따른 콘크리트의 경화성상 및 내구성에 관한 연구 (A Study on Hardened Properties and Durability of Concrete according to Unit-Water Content)

  • 구경모;임창혁;이의배;김영선;김영선;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.45-48
    • /
    • 2009
  • The performance of concrete mainly depend upon its water-cement ratio. If water percentage is excess in concrete, it may cause the degradation of performance. Because of these reasons, the change of water content is managed by using various evaluation method of unit water content. And criterion for the change of water content is regulated and used. However the criterion is set only considering production error and measurement error but criterion does not consider performance degradation of concrete. Therefore this study tries to investigate degradation of performance while adding extra water by artificial manipulation or management error in concrete, The contents of extra water for tests are set as 0, 20, 40, 60kg/m3, to examine the performance degradation of concrete, strength, shrinkage, cracks, carbonation are tested This study conclude that, when extra water content is excess than 20kg/m3 in concrete, then performance level of concrete declined rapidly. 80 it is very important to maintain quality of concrete for its better performance.

  • PDF

UV/H2O2 고도산화기술을 이용한 수중 잔류의약물질 제거 (Degradation of residual pharmaceuticals in water by UV/H2O2 advanced oxidation process)

  • 박진영;서상원;조익환;전용성;하현섭;황태문
    • 상하수도학회지
    • /
    • 제33권6호
    • /
    • pp.469-480
    • /
    • 2019
  • This study was conducted to evaluate the degradation and mineralization of PPCPs (Pharmaceuticals and Personal Care Products) using a CBD(Collimated Beam Device) of UV/H2O2 advanced oxidation process. The decomposition rate of each substance was regarded as the first reaction rate to the ultraviolet irradiation dose. The decomposition rate constants for PPCPs were determined by the concentration of hydrogen peroxide and ultraviolet irradiation intensity. If the decomposition rate constant is large, the PPCPs concentration decreases rapidly. According to the decomposition rate constant, chlortetracycline and sulfamethoxazole are expected to be sufficiently removed by UV irradiation only without the addition of hydrogen peroxide. In the case of carbamazepine, however, very high UV dose was required in the absence of hydrogen peroxide. Other PPCPs required an appropriate concentration of hydrogen peroxide and ultraviolet irradiation intensity. The UV dose required to remove 90% of each PPCPs using the degradation rate constant can be calculated according to the concentration of hydrogen peroxide in each sample. Using this reaction rate, the optimum UV dose and hydrogen peroxide concentration for achieving the target removal rate can be obtained by the target PPCPs and water properties. It can be a necessary data to establish design and operating conditions such as UV lamp type, quantity and hydrogen peroxide concentration depending on the residence time for the most economical operation.

심부지하수 수질 보호를 위한 천부포획정 공법

  • 김강주;박성민;염병우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.511-514
    • /
    • 2003
  • Nowadays, wells tapping the deep aquifers become general because water quality of the shallow groundwater has been gradually degraded over the last 30 years as a result of rapid industrialization and intensive agricultural activities. However, many of the deep wells also suffer problems of water-quality degradation in several years after the well installation, nevertheless those were properly completed and managed. It is believed that the heavy pumping from deep wells causes the doward movement of the contaminated, shallow groundwaters and introduces them into the deep aquifers. In this study, we introduces a shallow capture well system, which could effectively prevent the shallow groundwaters of poor water duality from moving into the deep aquifers by pumping of deep production wells. Even though additional costs are required to apply this system, we believe that this method could be appropriate for the deep wells that are important for the public health.

  • PDF

지하수수질측정망 자료를 이용한 유역단위 지하수 수질등급 평가 (Assessment of Groundwater Quality on a Watershed Scale by Using Groundwater Quality Monitoring Data)

  • 김정직;현윤정
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권6호
    • /
    • pp.186-195
    • /
    • 2021
  • In Korea, groundwater quality is monitored through National Groundwater Quality Monitoring Network (NGQMN) administered by Ministry of Environment. For a given contaminant, compliance to groundwater quality standards is assessed on a annual basis by monitoring the number of incidents that concentration exceeds the regulatory limit. However, this approach provides only a fractional information about groundwater quality degradation, and more crucial information such as location and severity of the contamination cannot be obtained. For better groundwater quality management on a watershed, a more spatially informative and intuitive method is required. This study presents two statistical methods to convert point-wise monitoring data into information on groundwater quality status of a watershed by using a proposed grading scale. The proposed grading system is based on readily available reference standards that classify the water quality into 4 grades. The methods were evaluated with NO3-, Cl-, and total coliform data in Geum River basin. The analyses revealed that groundwater in most watersheds of Geum River basin is good for domestic or/and drinking with no treatment. But, there was notable quality degradation in Bunam seawall and So-oak downstream standard watersheds contaminated by NO3- and Cl-, respectively.

수처리 시설 콘크리트 구조물의 오존 열화에 관한 문헌적 연구 (A Literature Study on the Ozone Degradation of Concrete Structures in Water Treatment Facilities)

  • 박진호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.177-178
    • /
    • 2015
  • Recently, Advanced water treatment facilities with Ozone are being introduced owing to domestic water pollution. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. it causes increase of maintenance cost and water quality degradation. Therefore, in this study, it will figure out problems of waterproofing/corrosion prevention construction method being applied to through existing studies.

  • PDF