Failure analysis on the phenomenon of water condensing of automotive head lamp assembly

자동차용 head lamp의 수밀원인 분석

  • 조영진 (한양대학교 신뢰성분석연구센터(RARC)) ;
  • 전종수 (한양대학교 신뢰성분석연구센터(RARC))
  • Published : 2008.11.05

Abstract

In this study, we try to find the root cause of water condensing failures in a headlamp using chemical and mechanical analysis. Through the surface inspection by OM, SEM and CT, it was found that water infiltrate into the headlamp through hotmelt adhesive debonding part caused by adhesion force degradation and poor quality. IR spectra shows that adhesion force degradation are characterized by increase of some functional group(1742, 1710, 1649, 1016). Through the ESPI measurement, it is turned out that bonding structural change by thermal expansion and degradation of adhesive can be the cause of void generation. So it is recommended that cooling passage and the bonding part should be redesigned to give a guarantee of less thermal stress and high adhesion quality.

Keywords