• Title/Summary/Keyword: water power

Search Result 5,424, Processing Time 0.04 seconds

Use of Nitrate and Ferric Ion as Electron Acceptors in Cathodes to Improve Current Generation in Single-cathode and Dual-cathode Microbial Fuel Cells (Single-cathode와 Dual-cathode로 구성된 미생물연료전지에서 전류발생 향상을 위한 전자수용체로서의 Nitrate와 Ferric ion의 이용)

  • Jang, Jae Kyung;Ryou, Young Sun;Kim, Jong Goo;Kang, Youn Koo;Lee, Eun Young
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.4
    • /
    • pp.414-418
    • /
    • 2012
  • The quantity of research on microbial fuel cells has been rapidly increasing. Microbial fuel cells are unique in their ability to utilize microorganisms and to generate electricity from sewage, pig excrement, and other wastewaters which include organic matter. This system can directly produce electrical energy without an inefficient energy conversion step. However, with MFCs maximum power production is limited by several factors such as activation losses, ohmic losses, and mass transfer losses in cathodes. Therefore, electron acceptors such as nitrate and ferric ion in the cathodes were utilized to improve the cathode reaction rate because the cathode reaction is very important for electricity production. When 100 mM nitrate as an electron acceptor was fed into cathodes, the current in single-cathode and dual-cathode MFCs was noted as $3.24{\pm}0.06$ mA and $4.41{\pm}0.08$ mA, respectively. These values were similar to when air-saturated water was fed into the cathodes. One hundred mM nitrate as an electron acceptor in the cathode compartments did not affect an increase in current generation. However, when ferric ion was used as an electron acceptor the current increased by $6.90{\pm}0.36$ mA and $6.67{\pm}0.33$ mA, in the single-cathode and dual-cathode microbial fuel cells, respectively. These values, in single-cathode and dual-cathode microbial fuel cells, represent an increase of 67.1% and 17.6%, respectively. Furthermore, when supplied with ferric ion without air, the current was higher than that of only air-saturated water. In this study, we attempted to reveal an inexpensive and readily available electron acceptor which can replace platinum in cathodes to improve current generation by increasing the cathode reaction rate.

Validation of Extreme Rainfall Estimation in an Urban Area derived from Satellite Data : A Case Study on the Heavy Rainfall Event in July, 2011 (위성 자료를 이용한 도시지역 극치강우 모니터링: 2011년 7월 집중호우를 중심으로)

  • Yoon, Sun-Kwon;Park, Kyung-Won;Kim, Jong Pil;Jung, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.371-384
    • /
    • 2014
  • This study developed a new algorithm of extreme rainfall extraction based on the Communication, Ocean and Meteorological Satellite (COMS) and the Tropical Rainfall Measurement Mission (TRMM) Satellite image data and evaluated its applicability for the heavy rainfall event in July-2011 in Seoul, South Korea. The power-series-regression-based Z-R relationship was employed for taking into account for empirical relationships between TRMM/PR, TRMM/VIRS, COMS, and Automatic Weather System(AWS) at each elevation. The estimated Z-R relationship ($Z=303R^{0.72}$) agreed well with observation from AWS (correlation coefficient=0.57). The estimated 10-minute rainfall intensities from the COMS satellite using the Z-R relationship generated underestimated rainfall intensities. For a small rainfall event the Z-R relationship tended to overestimated rainfall intensities. However, the overall patterns of estimated rainfall were very comparable with the observed data. The correlation coefficients and the Root Mean Square Error (RMSE) of 10-minute rainfall series from COMS and AWS gave 0.517, and 3.146, respectively. In addition, the averaged error value of the spatial correlation matrix ranged from -0.530 to -0.228, indicating negative correlation. To reduce the error by extreme rainfall estimation using satellite datasets it is required to take into more extreme factors and improve the algorithm through further study. This study showed the potential utility of multi-geostationary satellite data for building up sub-daily rainfall and establishing the real-time flood alert system in ungauged watersheds.

Antioxidant activity and comparative analysis of major functional compounds in liqueur using coffee and coffee-ground (커피와 커피박 침출주의 항산화 활성 및 주요 생리활성 물질의 비교 분석)

  • Kang, Jeong Eun;Park, Seon Kyeong;Guo, Tian Jiao;Kang, Jin Yong;Lee, Du Sang;Kim, Jong Min;Kwon, O-Jun;Lee, Uk;Heo, Ho Jin
    • Food Science and Preservation
    • /
    • v.23 no.4
    • /
    • pp.560-567
    • /
    • 2016
  • Sensory evaluation, in vitro antioxidant activities and main compounds of coffee water-extract, coffee liqueur (CL) and coffee-ground liqueur (CGL) were investigated to consider their industrialization. Sensory evaluation showed that all groups of CGL without 25% CGL (3 month) were relatively higher than CL groups. Total phenolic compounds and in vitro antioxidant activities such as 1,1-diphenyl-2picryl-hydrazyl (DPPH) radical scavenging activity and ferric reducing/antioxidant power (FRAP) were also performed. The group of 35% CGL had higher total phenolic compounds than others, and the result of DPPH radical scavenging activity was similar to that of total phenolic compounds. In addition, 35% CGL is comparable to the FRAP of coffee water extract (CE). Qualitative and quantitative analysis using high-performance liquid chromatography (HPLC) were performed, and chlorogenic acid as a ployphenolic compound and caffeine as a nonpolyphenolic compound were detected in all samples. Moreover, the HPLC analysis showed that CGLs contain a larger amounts of chlorogenic acid (difference of 0.3~10.5%) and also greater amounts of caffeine (difference of 10.0~18.2%) more then CE. Consequently, these results suggest that coffee-ground as coffee by-products could be used as commercially available food substances because of its physiological molecules remained.

Phenolic Content, Antioxidant Effect and Acetylcholinesterase Inhibitory Activity of Korean Commercial Green, Puer, Oolong, and Black Teas (국내 시판 녹차, 보이차, 우롱차 및 홍차의 폴리페놀 함량, 항산화 및 아세틸콜린에스터레이스 저해 효과)

  • Jeong, Chang-Ho;Kang, Su-Tae;Joo, Ok-Soo;Lee, Seung-Cheol;Shin, Young-Hee;Shim, Ki-Hwan;Cho, Sung-Hwan;Choi, Sung-Gil;Heo, Ho-Jin
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.230-237
    • /
    • 2009
  • The phenolic contents, antioxidant effects, and acetylcholinesterase inhibitory activities of hot water extracts prepared from various Korean commercial teas(green tea, puer tea, oolong tea, and black tea) were investigated. Total phenolic contents were in the range 72.03-85.62 mg/g. Flavonol contents of hot water extracts from green tea, puer tea, oolong tea, and black tea were 350.96, 254.17, 334.48, and 240.23 mg/100 g, respectively. Catechin contents were 2,920.35 mg/100 g in green tea, 1,016.23 mg/100 g in puer tea, 2,824.22 mg/100 g in oolong tea, and 1,006.51 mg/100 g in black tea. The highest caffeine content was in the green tea extract. All four extracts scavenged $ABTS^{{\cdot}+}$ radicals in a concentration-dependent manner, and the green tea extract was the most potent in this regard. The highest reducing power was observed in the green tea extract. All four extracts exhibited considerable antioxidative activities in linoleic acid autoxidation, $\beta$-carotene bleaching, and acetylcholinesterase inhibition assays; the effects were concentration-dependent and decreased in the order green tea > oolong tea > puer tea > black tea.

U.S. Admiralty Jurisdiction over aviation claims (항공사고에 관한 미국 해사법정관할)

  • Lee, Chang-Jae
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.31 no.2
    • /
    • pp.3-35
    • /
    • 2016
  • The United States Constitution gives power to the federal district courts to hear admiralty cases. 28 U.S.C. §.133, which states that "The district courts shall have original jurisdiction, exclusive of the Courts of the States, of any civil case of admiralty or maritime jurisdiction." However, the determination of whether a case is about admiralty or maritime so that triggers admiralty jurisdiction was not a simple question. Through numerous legal precedents, the courts have drawn a line to clarify the boundary of admiralty cases. This unique jurisdiction is not determined by the mere involvement of a vessel in the case or even by the occurrence of an event on a waterway. As a general rule, a case is within admiralty jurisdiction if it arises from an accident on the navigable waters of the United States (locus test) and involves some aspect of maritime commerce (nexus test). With regarding to the maritime nexus requirement, the US Supreme Court case, Executive Jet Aviation, Inc. v. City of Cleveland, held that federal courts lacked admiralty jurisdiction over an aviation tort claim where a plane during a flight wholly within the US crashed in Lake Erie. Although maritime locus was present, the Court excluded admiralty jurisdiction because the incident was "only fortuitously and incidentally connected to navigable waters" and bore "no relationship to traditional maritime activity." However, this historical case left a milestone question: whether an aircraft disaster occurred on navigable water triggers the admiralty jurisdiction, only for the reason that it was for international transportation? This article is to explore the meaning of admiralty jurisdiction over aviation accidents at US courts. Given that the aircraft engaged in transportation of passenger and goods as the vessels did in the past, the aviation has been linked closely with the traditional maritime activities. From this view, this article reviews a decision delivered by the Seventh Circuit regarding the aviation accident occurred on July 6, 2013 at San Francisco International Airport.

The Density and Strength Properties of Lightweight Foamed Concrete Using Stone-Powder Sludge in Hydrothermal Reaction Condition (수열반응 조건에서 석분 슬러지를 사용한 경량 기포 콘크리트의 밀도와 강도 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Choi, Se-Jin;Kim, Bong-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.687-693
    • /
    • 2006
  • The Stone Powder Sludge(below SPS) is the by-product from the process that translates stone power of 8mm under as crushed fine aggregate. It is the sludge as like cake that has average particle size of $7{\mu}m$, absorbing water content of 20 to 60%, and $SiO_2$ content of 60% over. Because of high water content of SPS, it is not only difficult to handle, transport, and recycle, but also makes worse the economical efficiency due to high energy consuming to drying. This study is aim to recycle SPS as it is without drying. Target product is the lightweight foamed concrete that is made from the slurry mixed with pulverized mineral compounds and foams through hydro-thermal reaction of CaO and $SiO_2$. Although in the commercial lightweight foamed concrete CaO source is the cement and $SiO_2$ source is high purity silica powder with $SiO_2$ of 90%, we tried to use the SPS as $SiO_2$ source. From the experiments with factors such as foam addition rate and replacement proportion of SPS, we find that the lightweight foamed concrete with SPS shows the same trends as the density and strength of lightweight foamed concrete increases according to decrease of foam addition rate. But in the same condition, the lightweight foamed concrete with SPS is superior strength and density to that with high purity silica. This trends is distinguished according to increase of replacement proportion of SPS, also the analysis of XRF shows that the hydro thermal reaction translates SPS to tobermorite. Although SPS has low $SiO_2$ contents, the lightweight foamed concrete with SPS has superior strength and density, because it reacts well with CaO due to extremely fine particles. We conclude that it is possible to replace the high purity silica as SPS in the lightweight foamed concrete experimentally.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Antioxidant and Antidiabetic Activities of Jerusalem Artichoke Composites Containing Gynura procumbens, Momordica charantia, and Curcuma longa via AMPK Activation (명월초, 여주 및 울금을 포함한 돼지감자 복합물의 항산화 및 AMPK 활성화를 통한 항당뇨 활성)

  • Lee, Soo-Jung;Hu, Wen-Si;Pyo, Jae-Ho;Ryu, Ji Hyeon;Kang, Dawon;Jeong, Bo-Young;Sung, Nak-Ju
    • Journal of Life Science
    • /
    • v.28 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • This study was performed to identify the antioxidant and ${\alpha}$-glucosidase inhibitory activities of water and 70% ethanol extracts of the three following herbs: G. procumbens, M. charantia, and C. longa. In addition, the antioxidant and antidiabetic activities of five types of Jerusalem artichoke composites (JA1 - 5), which were prepared by adding ethanol extracts of several herbs to Jerusalem artichoke concentrate, were studied and compared. The results showed that the total phenol and flavonoid contents of the ethanol extracts were higher than those of the water extracts. The DPPH and ABTS radical scavenging activities and reducing power depended on the total phenol and flavonoid contents. The antioxidant activities of ethanol extracts from G. procumbens and C. longa were comparable. Moreover, the ${\alpha}$-glucosidase inhibitory activity of the ethanol extracts ($2,000{\mu}g/ml$) from each herb was found to be over 50%. In contrast, the five types of JA composites showed higher total phenol and flavonoid contents than those of JA concentrate. In addition, increased antioxidant and ${\alpha}$-glucosidase inhibitory activities were observed, with that of JA1 being the highest. However, all concentrations ($1{\sim}100{\mu}g/ml$) of JA tested did not affect the cell viability of Chang cells. In addition, JA induced the activation of AMP-activated protein kinase (AMPK) in Chang cells and significantly increased the glucose uptake in C2C12 cells. Therefore, it could be concluded that the JA composites (JA1 - 5) mixed with G. procumbens, M. charantia, and C. longa extracts were effective in increasing the extracts' antioxidant and antidiabetic activities.

Two-Dimensional Interpretation of Ear-Remote Reference Magnetotelluric Data for Geothermal Application (심부 지열자원 개발을 위한 원거리 기준점 MT 탐사자료의 2차원 역산 해석)

  • Lee, Tae-Jong;Song, Yoon-Ho;Uchida, Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.145-155
    • /
    • 2005
  • A two-dimensional (2-D) interpretation of MT data has been performed for the purpose of fracture detection for geothermal development. Remote stations have been operated in Kyushu, Japan (480 km apart) as well as in Korea (60 km and 165 km apart in 2002 and 2003 data set, respectively). Apparent resistivity and phase curves calculated by remote processing with the Japan remote data showed enough quality for 2-D inversion for the whole frequency range. Remote reference processing with Korea remote reference data also showed quite good continuity in apparent resistivity and phase curves except some noisy frequency bands; around the power frequency, 60 Hz, and around the dead band $10^{-1}Hz\;Hz\;\~1\;Hz$, where the natural EM signal is known to be very weak. Even though the subsurface showed severe three-dimensional (3-D) characteristics in the survey area so that 2-D inversion by itself could not give enough information for deep geological structures, the 2-D inversion for the 5 survey lines showed several common features. The conductive semi-consolidate mudstone layer is dipping from north to south (about 500 m depth on the south and 200 m on the north most part of the survey area). The boundary between the low (L-2) and high (H-2) resistivity anomalies can be thought as a major fault with strike $N15^{\circ}E$, passing through the sites 206, 112 and 414. The shallow (< 1 km) conductive anomalies (L-4) seem to be fracture zones having strike E-W (at site 105) and $N60^{\circ}W$ (at site 434). And there exists a conductive layer in the western and west-southern part of the survey area in the depth below $2\~3\;km$, for which further investigation is to be needed.