• Title/Summary/Keyword: water level-storage

Search Result 499, Processing Time 0.026 seconds

Effects of Dehydration Methods and Storage Conditions on Germinability of Pelleted Carrot Seeds (당근 펠렛종자의 건조방법 및 저장조건이 발아성에 미치는 영향)

  • Kang, Jum-Soon;Son, Beung-Gu;Choi, Young-Whan;Lee, Yong-Jae;Joo, Woo-Hong;Lim, Chae-Shin;Park, Young-Hoon
    • Journal of Life Science
    • /
    • v.19 no.4
    • /
    • pp.526-531
    • /
    • 2009
  • This study was conducted to identify the optimum condition for dehydration and storage for maintaining the seed vigor in pelleted carrot seeds. The water content of solid materials of un-pelleted seeds was 4.9% (F.W. basis), and that of pelleted seeds was 24%. When we dehydrated pelleted seeds for 3 hr at $25^{\circ}C$, $35^{\circ}C$, and $45^{\circ}C$, all seeds were dehydrated to 5% - the same level of water content as that before pelleting. Pelleted seeds did not show any significant difference in germination from un-pelleted seeds, and neither was there any significant time or germination difference between pelleted and un-pelleted seeds at the tested dehydration temperatures. However, the $T_{50}$ value of pelleted seeds increased about 3 days larger than that of un-pelleted seeds. Germination speed of pelleted seeds in which the dehydration period was prolonged at $45^{\circ}C$ was delayed compared to those prolonged at $25^{\circ}C$ or $35^{\circ}C$ for the same period. The optimum dehydration condition, which could be applied for large scale in the industry, was dehydration at $35^{\circ}C$ for 3 hr, and the optimum storage temperature which could maintain the seed performance was $5^{\circ}C$.

The Changes of Lipid Oxidation and Fatty Acid Composition of Extruded Pellet Feed by Dietary Moisture Level and Storage Temperature (수분함량과 저장온도에 따른 배합사료의 지방산화 및 지방산 조성 변화)

  • Jang, Mi-Soon;Kim, Kyoung-Duck;Kim, Kang-Woong;Lee, Jong-Yun;Kang, Yong-Jin
    • Journal of Aquaculture
    • /
    • v.21 no.4
    • /
    • pp.226-233
    • /
    • 2008
  • This study investigated the effects of dietary moisture level and storage temperature on lipid oxidation and fatty acids composition of the extruded pellet feed. The diets containing the moisture levels of 5%, 15% and 25% were prepared by adding moisture (water) to the commercial extruded pellets and stored at $5^{\circ}C$, $20^{\circ}C$ (room temperature) and $35^{\circ}C$. The samples for analysis were collected at every 2 days for 10 days. Acid value (AV), peroxide value (POV), 2-thiobarbituric acid (TBA) value and fatty acid composition of the feeds were measured. No differences in the AV, POV and TBA value were observed in feed containing 5% moisture at all storage temperatures for 10 days. However, the AV, POV and TBA value of diets containing 15% and 25% moisture increased rapidly at $20^{\circ}C$ and $35^{\circ}C$ after 4 days. Fatty acids compositions of feeds containing 5% moisture did not change during the storage periods at $5^{\circ}C$ and $20^{\circ}C$. However, 5% moisture feed stored at $35^{\circ}C$ increased monoene fatty acid content and decreased the contents of polyene fatty acid, PUFA (polyunsaturated fatty acid)/SFA (saturated fatty acid) and $(C_{20:5}+C_{22:6})/C_{16:0}$ after 4 days. Also, 15% moisture feed stored at $35^{\circ}C$ showed increased monoene fatty acid content and decreased $(C_{20:5}+C_{22:6})/C_{16:0}$ after 2 days. The diet containing 25% moisture showed increased monoene fatty acid content and decreased contents of PUFA, PUFA/SFA and $(C_{20:5}+C_{22:6})/C_{16:0}$ at all temperatures after 2 days. In this study, lipid oxidation can occur in the extruded pellet feeds of 15% and 25% moisture at room temperature after 2 days.

Effects of Storage Temperature on the Survival of Vibrio mimicus K-1 in Seawater and Arkshell (해수와 피조개에서 Vibrio mimicus K-1의 생존에 대한 보관온도의 영향)

  • KOH Byeong-Ho;LEE Won-Dong;ANN Sung-Kee;KIM Ji-Hoe;LEE Myung-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.277-281
    • /
    • 1997
  • The cell density changes of Vibrio mimicus K-1 in sea water and arkshell feeding it were examined at various temperature. The strain was suspended in sterilized sea water and storaged at experimental temperature $(5,\;10,\;15,\;20,\;and\;28^{\circ}C)$). At intervals of up to 10 days, aliquots of each suspension were plated onto BHI agar. At 5 and $10^{\circ}C$, the plate counts of V. mimicus K-1 showed a rapid decline, which 3s known to be a reault of this bacterium's entering into the viable but non culturable state. At 20 and $28^{\circ}C$, however, V. mimicus K-1 are stable over the 10 days experimental periods. V. mimicus K-1 was fed to arkshell, which was subsequently stored at temperatures ranging from 5 to $20^{\circ}C$ for 10 days. The samples of arkshell were homogenized and plated at intervals to determine the cell density of V. mimicus K-1 and total aerobic population of bacteria present. At 5 and $10^{\circ}C$, the numbers of V. mimicus K-1 in sea water rapid decreased over the 10 days experimental periods. However, little change of V. mimicus K-1 density was observed in shellstock arkshell at 5 and $10^{\circ}C$. While, V. mimicus K-1 density was decreased more rapidly to level below limit of dectection in shucked arkshell at same temperature. Incubation at the higher temperature $(20^{\circ}C)$ resulted in large increase in total aerobic bacterial number of shellstock arkshell. These results suggest that even with proper storage, indigenous levels of V. mimicus may remain sufficiently high in shellstock arkshell to produce infection in compromise hosts.

  • PDF

The Development of Multi-channel Electrical Conductivity Monitoring System and its Application in the Coastal Aquifer (다채널 전기전도도 모니터링 시스템의 개발과 연안지역 공내수 모니터링에 대한 적용 사례)

  • Shin, Je-Hyun;Hwang, Se-Ho;Park, Kwon-Gyu;Park, Yun-Seong;Byun, Joong-Moo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.156-162
    • /
    • 2005
  • Particularly in research related to seawater intrusion the change of fluid electrical conductivity is one of major concerns, and effective monitoring can help to optimize a water pumping performance in coastal areas. Special considerations should be given to the mounting of sensors at proper depth during the monitoring design since the vertical distribution of fluid electrical conductivity is sensitive to the characteristics of seawater intrusion zone. This tells us the multi-channel electrical conductivity monitoring is of paramount consequence. It, however, is a rare event when this approach becomes routinely available in that commonly used commercial stand-alone type sensors are very expensive and inadequate for a long term monitoring of electrical conductivity or water level due to their restricted storage and difficulty of real-time control. For this reason, we have developed a real-time monitoring system that could meet these requirements. This system is user friendly, cost-effective, and easy to control measurement parameters - sampling interval, acquisition range, and others. And this devised system has been utilized for the electrical conductivity monitoring in boreholes, Yeonggwang-gun, Korea. Monitoring has been consecutively executed for 24 hours, and the responses of electrical conductivity at some channels have been regularly increased or decreased while pumping up water. It, with well logging data implemented before/after pumping water, verifies that electrical conductivity changes in the specified depths originate from fluid movements through sand layer or permeable fractured rock. Eventually, the multi-channel electrical conductivity monitoring system makes an effective key to secure groundwater resources in coastal areas.

Evaluation of water drainage according to hydraulic properties of filling material of sand dam in Mullori, Chuncheon (춘천 물로리 지역 샌드댐 채움재 수리특성에 따른 배수량 평가)

  • Chung, Il-Moon;Lee, Jeongwoo;Kim, Min-Gyu;Kim, Il-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.923-929
    • /
    • 2022
  • The Chuncheon Mullori area is an underprivileged area of water welfare where local water supply is not supplied, and it is supplying water to the villages with small water supply facilities using lateral flow and groundwater as water sources. This is an area with poor water supply conditions, such as relying on water trucks due to water shortages during the recent severe drought. Therefore, in order to solve the problem of water shortage during drought and to prepare for the increasing water demand, a sand dam was installed along the valley, and this facility has been operating since May 2022. In this study, repeated simulations were performed according to the hydraulic conductivity of the filler material and the storage coefficient value for the inflow condition for about two years from mid-March 2020 to mid-March 2022. For each case, the amount of discharge through the perforated drain pipe was calculated. Overall, as the hydraulic conductivity increased, the amount of discharge and its ratio increased. However, when the hydraulic conductivity of the second floor was relatively low, the amount of discharge increased and then decreased as the hydraulic conductivity of the third floor increased. This is considered to be due to the fact that the water level was kept low due to the rapid drainage compared to the net inflow into the third floor because the water permeability of the third floor and the drainage coefficient of the drain pipe were large. As a result of simulating the flow of the open channel in the upper part of the sand dam as a hypothetical groundwater layer with very high hydraulic conductivity, the decrease in discharge rate was slower than the increase in the hydraulic conductivity of the hypothetical layer, but it was clearly shown that the discharge volume decreased relatively as the hydraulic conductivity of the virtual layer increased.

Simulation Conditions based Characteristics of Spatial Flood Data Extension (모의조건에 따른 홍수 유출자료의 공간적 확장 영향분석)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.6
    • /
    • pp.501-511
    • /
    • 2014
  • The effects of initial conditions and input values of the rainfall-runoff model were studied in the applications of a lumped concept model for flood event data extension. For the initial conditions of the rainfall-runoff model, baseflow effects and spatial distributions of saturation points ($R_{sa}$) for the storage function methods (SFM) were analyzed. In addition, researches on the effects of rainfall data conditions as input values for the rainfall-runoff model were performed. The Chungju Dam watershed was selected and divided into 3 catchments including smaller size of 22 sub-catchments. The observed discharge and inflow amounts at Yeongwol 1, Chungju Dam, and Yeongwol 2 water level stations were individually operated as criteria for flood data extension in 30 flood events from 1993 to 2009. Direct and base flow were distinguished from a stream flow. In order to test capability of flood data extension, obtained base flow was applied to the rainfall-runoff model for three water level stations. When base flow was adopted in the model, the Nash-Sutcliffe Efficiency(NSE) was increased. The numbers of over satisfaction for model performance (>0.5) were increased over 10%. Saturation points ($R_{sa}$) which strongly influence the runoff amount when rainfall starts were optimized based on the runoff amount at three water level stations. The sizes of saturation points for three locations were similar which means saturation point size is not depending on the runoff amount. The effects of rainfall information for flood runoff were tested at 2002ev1 and 2008ev1. When increased the amount of rainfall information, the runoff simulations were closer to the simulations with full of rainfall information. However, the size of improvement was not substantial on rainfall-runoff simulations in terms of the size of total amount of rainfall.

Antioxidant Activity of Black Garlic (Allium sativum L.) (흑마늘의 항산화 활성)

  • Shin, Jung-Hye;Choi, Duck-Joo;Lee, Soo-Jung;Cha, Ji-Young;Sung, Nak-Ju
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.8
    • /
    • pp.965-971
    • /
    • 2008
  • The antioxidant activities of hot water and ethanol extracts from fresh, steamed and black garlic were compared. The levels of phenolic compounds of extracts from fresh, steamed and black garlic were $0.81{\sim}0.99\;mg$/100 g and their contents were not significantly different. The contents of flavonoids in ethanol extracts, $0.96{\pm}0.05{\sim}1.06{\pm}0.09\;mg$/100 g, was higher than hot water extracts. DPPH radical scavenging activity was higher in ethanol extract. Although the highest level was $69.40{\pm}0.13%$ in concentration of 10 mg/mL from black garlic ethanol extract, ethanol extracts showed $50.55{\pm}1.40%$ in concentration of 15 mg/mL. Reducing power was significantly higher in black garlic extract and higher in the order of black garlic> fresh garlic> steamed garlic in ethanol extract. Hydroxyl radical scavenging activity was higher in ethanol extract, showing over 60% in concentration of 5 mg/mL. In oil emulsion, TBA value was significantly lower in hot water extracts from black garlic, however ethanol extracts were not significantly different. TBA value of ethanol extract were $1.49{\pm}0.08{\sim}2.11{\pm}0.16\;MA\;mg/kg$ and $1.33{\pm}0.18{\sim}1.62{\pm}0.19\;MA\;mg/kg$ from steamed and black garlic, respectively. Antioxidant activity to the linoleic acid was $72.71{\pm}2.17{\sim}88.74{\pm}3.70%$ in 1-day storage, but its level was increased at 4-day storage to $86.67{\pm}3.76{\sim}92.50{\pm}0.87%$.

Control of Stretching of Tomato (Lycopersicon esculentum Mill.) on Cylindrical Paper Pot Seedling Using High-Salinity Potassium Fertilizers (고농도 칼륨처리를 활용한 원통형 종이포트 토마토묘의 도장억제)

  • Xu, Chan;Kim, Si Hong;Kim, Dae Hoon;Kim, Jae Kyung;Heo, Jae Yun;Vu, Ngoc Thang;Choi, Ki Young;Kim, Il Seop;Jang, Dong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.354-364
    • /
    • 2020
  • This study was conducted to examine the potential of inducing salinity stress on cylindrical paper pot tomato seedlings to inhibit overgrowth. Potassium fertilizers, sulfate of potash (K2SO4), muriate of potash (KCl), and monopotassium phosphate (KH2PO4), were prepared as two solutions of (5 and 10) dS·m-1 salinity level, respectively, to investigate the influence on tomato (Lycopersicon esculentum Mill.) seedling growth. We also investigated the adaptability and survivability of treated tomato seedlings with high-salinity potassium (10 dS·m-1 KCl) to harsh environmental conditions (water deficit, low temperature, and storage conditions). Repeated addition of high-salinity level KCl, K2SO4, or KH2PO4 markedly decreased the dry matter of shoot and root, leaf area, and net assimilate rates (NAR) but increased the stem diameter of seedlings. Among the three sources, the relative growth rate of plant height (RGRH) was most sensitive to KCl addition; increasing salinity levels of KCl solution decreased the RGRH of seedlings. The compactness, which directly reflects the stocky growth index, increased in KCl or KH2PO4 treatments. After a week's water deficit, severely wilted seedlings were observed in control seedlings (untreated with KCl), but no wilted seedlings were observed in the KCl treated seedlings, and the relative water content (RWC) of the untreated seedlings significantly decreased by 23 %, while that of the pretreated seedlings only decreased by 8 %. The increase in ion leakage of KCl treated seedlings at low temperatures was less than that of untreated seedlings. Furthermore, there was far lower damage proportion on pretreated seedlings at (9, 12, and 15)℃ storage temperatures after 20 days, compared with on unpretreated seedlings. Our results suggest that high-salinity potassium fertilizer, especially KCl, is effective in preventing tomato seedling overgrowth, while it also improves tolerance.

Evaluation on Four Volatile Organic Compounds (VOCs) Contents in the Groundwater and Their Human Risk Level

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-Hyun;Lee, Gyeong-Mi;Kim, Ki-In;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.4
    • /
    • pp.235-250
    • /
    • 2017
  • In this study, we monitored 4 volatile organic compounds (VOCs) such as chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane in groundwater samples to determine the detection frequency and their concentrations and evaluated the health risk level considering ingestion, inhalation, and skin contact. 75 groundwater wells were selected. 24 wells were from monitoring background groundwater quality level and 51 wells were from monitoring groundwater quality level in industrial or contamination source area. In the results, the detection frequency for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane was 42.3%, 8.1%, 6.0%, and 3.4%, respectively. The average concentrations of VOCs were high in the order of chloroform ($1.7{\mu}g\;L^{-1}$), dichloromethane ($0.08{\mu}g\;L^{-1}$), tetrachloromethane ($0.05{\mu}g\;L^{-1}$), and 1,2-dichloroethane ($0.05{\mu}g\;L^{-1}$). Chloroform had the highest detection frequency and average detection concentration. In the contaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, 1,2-dchloroethane, and tetrachloromethane. The average concentrations for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane were $2.23{\mu}g\;L^{-1}$, $0.08{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.06{\mu}g\;L^{-1}$, respectively. All the 4 compounds were detected at industrial complex and storage tank area. The maximum concentration of chloroform, dichloromethane, and 1,2-dichloroethane was detected at industrial complex area. Especially, the maximum concentration of chloroform and dichloromethane was detected at a chemical factory area. In the uncontaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, and 1,2-dchloroethane and tetrachloromethane was not detected. The average concentrations for chloroform, dichloromethane, and 1,2-dichloroethane were $0.57{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.03{\mu}g\;L^{-1}$, respectively. Although chloroform in the uncontaminated groundwater was detected the most, the concentration of chloroform was not exceeding water quality standards. By land use, the maximum detection frequency of 1,2-dichloroethane was found near a traffic area. For human risk assessment, the cancer risk for the 4 VOCs was $10^{-6}{\sim}10^{-9}$, while the non-cancer risk (HQ value) for the 4 VOCs is $10^{-2}{\sim}10^{-3}$.

A Study of Monitoring and Operation for PEM Water Electrolysis and PEM Fuel Cell Through the Convergence of IoT in Smart Energy Campus Microgrid (스마트에너지캠퍼스 마이크로그리드에서 사물인터넷 융합 PEM 전기분해와 PEM 연료전지 모니터링 및 운영 연구)

  • Chang, Hui Il;Thapa, Prakash
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.6
    • /
    • pp.13-21
    • /
    • 2016
  • In this paper we are trying to explain the effect of temperature on polymer membrane exchange water electrolysis (PEMWE) and polymer membrane exchange fuel cell (PEMFC) simultaneously. A comprehensive studying approach is proposed and applied to a 50Watt PEM fuel cell system in the laboratory. The monitoring process is carried out through wireless LoRa node and gateway network concept. In this experiment, temperature sensor measure the temperature level of electrolyzer, fuel cell stack and $H_2$ storage tank and transmitted the measured value of data to the management control unit (MCU) through the individual node and gateway of each PEMWE and PEMFC. In MCU we can monitor the temperature and its effect on the performance of the fuel cell system and control it to keep the lower heating value to increase the efficiency of the fuel cell system. And we also proposed a mathematical model and operation algorithm for PEMWE and PEMFC. In this model, PEMWE gives higher efficiency at lower heating level where as PEMFC gives higher efficiency at higher heating value. In order to increase the performance of the fuel cell system, we are going to monitor, communicate and control the temperature and pressure of PEMWE and PEMFC by installing these systems in a building of university which is located in the southern part of Korea.