• Title/Summary/Keyword: water drain

Search Result 363, Processing Time 0.024 seconds

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

The Study on the Dry Floor Tile Unit System used Resin Mat (수지매트를 이용한 바닥타일 건식공법 시스템에 관한 연구)

  • 김성식;임남기;정병훈;정재영;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.185-190
    • /
    • 2001
  • The purpose of this study is the development of practical Dry floor tile unit method that settle the defect of a wet method and designed for resin mat. With use of PE resin which is confirmed the basic property, it is developed that resin mat, joint-sealing compound with fixed form and space management to Dry floor tile unit method. The result of this study is below. 1) To acquire above the 4kgf/$\textrm{cm}^2$ - construction specification criterion, the bonding space that between resin mat and tile has to occupy the 50% of resin mat module space(10,000$\textrm{cm}^2$). 2) Criteria of bonding part plane is below. simpleness of metal form. productivity, uniform quality after injection molding cooling, easy cutting for remain space management, adhesive property, construction ability, transformation of a severed piece under pressure and so on. 3) To get the shape that could protect the interfacial breakdown, it is designed that resin mat and tile are unified after the bond input. 4) Adapted joint-sealing compound is the material of urethane kinds wedge form. Resin mat has the water passageway that could drain the water. 5) To manage the severed piece of tile, the resin mat is likely to divide the half and the quarter and the plastic drainage is developed in the severed piece.

  • PDF

A Study on the Development of Dewatering Mold Form for Performance Improvement of Concrete (콘크리트 성능개선을 위한 탈수거푸집공법의 실용화 연구)

  • Woo Kwang-Min;Lee Hak-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.88-95
    • /
    • 2003
  • Dewatering mold form get many holes on the surface to drain excessive water from combine concrete. While fiber is adhered to the forms inter surface, that makes it possible to improve concrete workability by draining excess water through the holes. We can expect the outer layer to solidify and to compact and get improvement of concretes durability. Maybe, it is valuable enough that dewatering mold form is put to practical use. On this study, the purpose is to obtain fundamental data for effective dewatering mold and properties of exposed concrete with the form, and ultimately, is to propose practical theory.

Characteristics of Structural Behavior of Unplasticized Polyvinyl Chloride (PVC-U) Pipe Buried Underground (지중매설 경질폴리염화비닐관의 구조적 거동)

  • Kim, Sun-Hee;Cheon, Jinuk;Kim, Eung-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.16-23
    • /
    • 2015
  • The industrialization and urbanization forced to increase the density of pipelines such as water supply, sewers, and gas pipelines. The materials used for the existing pipe lines are mostly composed of concretes and steels, but it is true that the development for more durable and efficient materials has been continued performed to produce long lasting pipe lines. Recently, underground pipes serve in diverse applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. In this paper, we present the result of investigation pertaining to the structural behavior of unplasticized polyvinyl chloride (PVC-U) flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, pipe stiffness, 4-point bending test, experimental and analytical studies are conducted. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is about 8% although there are significant variations in the mechanical properties of the pipe material. In addition, it was found by the 4-point bending test there is no problem in the connection between the pipes by coupler.

Sewerage rehabilitation strategy based on sewer capacity evaluation (하수관거 통수능 검토를 통한 관거 개선방안 연구)

  • Ryu, Jaena;Oh, Jeill;Oh, Sukho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.47-55
    • /
    • 2009
  • Sewers are important national infrastructure and play an essential part by handling both wastewater and stormwater to minimise problems caused to human life and the environment. However, they can cause urban flooding when rainfall exceeds the system capacity. Sewer flooding is an unwelcome and increasingly frequent problem in many urban areas, and its frequency will increase over time with urbanisation and climate change. Under current standards, sewers are designed to drain stormwater generated by up to 10 year return period storms, but data suggests that many in practice have been experienced flooding with exceeding system capacity under increased storm events. A large number of studies has considered upgrading or increasing the design standard but there are still lack of information to propose a suitable return period with the corresponding system quantity to achieve. A methodology is required to suggest a proper level of standard within a suitable sewerage rehabilitation planning that can avoid the exceedance problem. This study aimed to develop a methodology to support effective sewer rehabilitation that could prevent urban flooding mainly resulted from the exceedance of existing storm sewer system capacity. Selected sewerage rehabilitation methods were examined under different storm return periods and compared to achieve the best value for money.

Survey on sewerage operation/management planning for flooding (II) (하수관거시설의 침수대응 운영·관리 실태 연구 (II))

  • Ryu, Jaena;Cha, Young Joo;Oh, Jeill;Hyun, In Hwan;Kim, Young-Ran;Chang, Dae-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • Under current design standard, sewers are designed to drain stormwater generated up to 10 year return period of storms. This implies sewer flooding could occur from rainfall exceeding a 10 year return period. 5, 10, 20 and 30 year return period of storm intensities were calculated for 22 locations (cities) of meterological stations over the nation and compared to the recorded rainfall intensities for the last 30 years. The comparison resulted in the numbers of year maximum rainfall intensities exceeded each return period. Using the questionnaire survey for "the incidences of flooding since 1980" of the previous paper (Survey on sewerage operation/management planning for flooding (I)), the actual rainfall records on the date of flooding events were analyzed to demonstrate the number of flooding events caused by the exceedance of sewer capacity. For the last 30 years, more than 6 years of year maximum rainfall intensity (20%) were larger than the 10 year return period of storm in 4 cities of the 22 used for the first analysis. The number of rainfall records that exceeded the 10 year return period was 50 of the 260 actual flooding events investigated from the survey.

A Study on Motion of a Flooding and Un-steerable Vessel in Stormy Weather Condition (침수된 조타불능선의 악천후에서의 거동연구)

  • KIM, Sung-Soo;PARK, Byung-Soo;KANG, Dong-Hoon;LEE, Jong-Hyun;CHO, Hyun-Kuk
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.1
    • /
    • pp.286-296
    • /
    • 2017
  • This paper conducted a simulation to research the motion of a vessel, which had the flooding accident in the Bering Sea in 2014, thereby being flooded and un-steerable. As the wind condition was very harsh, the vessel was modeled as 3D including large upper deck structures and the Fujiwara's method was used for an estimation of the effect of wind forces and moments acting on ship. In the case of wave influence, AQWA-Drift that enables considering the effects of drift force and AQWA-Naut that enables considering the effects of green water were mainly used. Basically, loading and flooding condition were equal to the accident condition but half-drained condition was also used to consider drain ability. Furthermore, both 6 DOF and 5 DOF option that Yaw motion is fixed, were utilized to compare the steerable and un-steerable condition. As a result, the author found out that what roll angle triggers green water, how often it happens, and how the vessel moves on the stormy weather condition.

A Study on Seepage Control of Levee with Pervious Toe Drain (본배수공을 이용한 하천제방의 침윤조절에 관한 연구)

  • Lee, Sang-Ho;Kong, Young-San;Lee, Nam-Joo;Yu, Kwon-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.162-166
    • /
    • 2011
  • 하천제방은 가장 치수효과가 높은 홍수방어시설로서 홍수 시 유수를 원활하게 소통시키고 제내지를 보호하기 위해 하천을 따라 축조한 시설이다. 누수에 의한 제방파괴는 제내지 제체에 드러난 포화표면이 결정적인 요인이 되므로 침윤선을 낮추어 제체하부에 위치하도록 해야 하며 누수가 발생한 제방에 대해서는 적절한 보강기법을 적용해야 한다. 본 연구에서는 하천제방 축조 또는 보강 시 누수에 의한 파괴를 방지하기 위한 방법으로 미국 공병단과 일본 국토기술연구센터에서 사용하는 기법 중 하나인 배수공을 두어 침윤선을 조절하는 방법을 적용하였다. 구체적으로 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 가지는 경우의 제방 실험 및 수치 모형 보정 결과를 비교하였다. 침투 수치 모의는 SEEP/W 프로그램으로 검토하였다. 실험에 적용한 제방의 규격은 제방폭 2.6 m, 둑마루폭 0.4 m, 사면경사 1:2, 제방 높이 0.55 m, 수위 0.5 m이다. 배수공이 없는 제방은 사면에서 누수가 발생하였으며, 배수공 바닥폭이 0.4 m인 공병단과 일본 국토기술연구센터에서 제시하는 배수공을 설치하였을 때는 누수가 발생하지 않았다. 같은 배수공 바닥폭을 가지는 공병단과 일본 국토기술연구센터식 배수공을 설치한 제방의 실험을 비교한 결과, 일본국토기술연구센터식 배수공을 설치한 제방의 침윤선이 공병단식 배수공을 설치한 제방보다 낮았다. 즉, 일본 국토기술연구센터식 사각형 배수공이 다소 안정한 것으로 분석되었다.

  • PDF

Study on Flood Mitigation Effect in Urban Stream Basin with Underground drain (지하방수로 설치에 따른 도시하천의 홍수저감효과 분석)

  • Hur, Sung-Chul;Lee, Jong-Tae;Kim, Hyo-Ki;Lim, Taek-Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.224-228
    • /
    • 2007
  • 도시하천인 중랑천을 대상으로 EAP 수립을 위한 한 방안으로서 계획규모를 초과하는 200년 빈도(현재 설계빈도는 100년 빈도임) 홍수에 대하여 한강홍수위 변화에 따른 월류부 위치 (시경계, 당현천 합류점, 월계1교, 묵동천 합류점)와 방수로 설계조건인 횡월류부 폭(30, 50, 70 m), 월류고(계획, 위험, 경계홍수위) 및 하류단 경계조건(평수위, 100년 빈도, 200년 빈도)에 따른 하류부 수위 저감효과를 분석하는 기술적 판단 과정을 제시하였다. 부정류 해석을 통하여 각 조건에 따른 저감효과를 분석하였다. 방수로 설치위치에 따른 홍수위 저감효과는 동일규모 방수로일 때 시경계부근에 설치한 경우에서 가장 큰 효과를 나타내고 있어 최적의 지점으로 분석되었다. 또한, 가장 취약지구인 당현천 부근의 홍수위는 당현천 합류지점에 방수로를 설치한 경우에 가장 낮아지는 것으로 분석되었다. 횡월류부의 폭과 월류고에 따라 중하류부 일정구간에서 홍수위가 100년 빈도로 저감되는 효과를 나타내었으며, 월류부 폭 및 월류고가 클수록 그 영향이 크게 나타났으나, 한강의 배수위 영향구간인 묵동천 합류점 하류구간에서는 그 영향이 감소하였다. 또한, 전반적으로 한강홍수위 변화에 따라 하류부에서의 영향은 컸으나, 당현천 상류구간에는 그 영향이 작았다.

  • PDF