DOI QR코드

DOI QR Code

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Yan, Changqi (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Meng, Zhaoming (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Chen, Kailun (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Song, Shaochuang (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Yang, Zonghao (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University) ;
  • Yu, Jie (Fundamental Science on Nuclear Safety and Simulation Technology Laboratory, Harbin Engineering University)
  • Received : 2016.03.28
  • Accepted : 2016.08.09
  • Published : 2016.12.25

Abstract

To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

Keywords

References

  1. M.H. Prasad, A.J. Gaikwad, A. Srividya, A.K. Verma, Failure probability evaluation of passive system using fuzzy Monte Carlo simulation, Nucl. Eng. Design 241 (2011) 1864-1872. https://doi.org/10.1016/j.nucengdes.2011.02.025
  2. T. Zhou, J. Li, X. Ru, C. Sheng, J. Chen, Y. Huang, Z. Xiao, Application and development of passive technology in nuclear power units, Proc CSEE 33 (2013) 81-89.
  3. H.S. Park, K.Y. Choi, S. Cho, C.K. Park, S.J. Yi, C.H. Song, M.K. Chung, Experiments on the heat transfer and natural circulation characteristics of the passive residual heat removal system for an advanced integral type reactor, J. Nucl. Sci. Technol. 44 (2007) 703-713. https://doi.org/10.1080/18811248.2007.9711859
  4. J. Wu, Q. Bi, C. Zhou, Experimental study on circulation characteristics of secondary passive heat removal system for Chinese pressurized water reactor, Appl. Thermal Eng. 77 (2015) 106-112. https://doi.org/10.1016/j.applthermaleng.2014.12.014
  5. P. Bardet, E. Blandford, M. Fratoni, A. Niquille, E. Greenspan, P.F. Peterson, Design, analysis and development of the modular PB-AHTR, American Nuclear Society, La Grange Park (IL), 2008.
  6. J. Serp, M. Allibert, O. Benes, S. Delpech, O. Feynberg, V. Ghetta, D. Heuer, D. Holcomb, V. Ignatiev, J.L. Kloosterman, L. Luzzi, E. Merle-Lucotte, J. Uhlir, R. Yoshioka, D. Zhimin, The molten salt reactor (MSR) in generation IV: overview and perspectives, Prog. Nucl. Energy 77 (2014) 308-319. https://doi.org/10.1016/j.pnucene.2014.02.014
  7. C. Wang, D. Zhang, S. Qiu, W. Tian, Y. Wu, G. Su, Study on the characteristics of the sodium heat pipe in passive residual heat removal system of molten salt reactor, Nucl. Eng. Design 265 (2013) 691-700. https://doi.org/10.1016/j.nucengdes.2013.09.023
  8. C. Wang, Z. Guo, D. Zhang, S. Qiu, W. Tian, Y. Wu, G. Su, Transient behavior of the sodium-potassium alloy heat pipe in passive residual heat removal system of molten salt reactor, Prog. Nucl. Energy 68 (2013) 142-152. https://doi.org/10.1016/j.pnucene.2013.07.001
  9. Y.J. Chung, S.H. Yang, H.C. Kim, S.Q. Zee, Thermal hydraulic calculation in a passive residual heat removal system of the SMART-P plant for forced and natural convection conditions, Nucl. Eng. Design 232 (2004) 277-288. https://doi.org/10.1016/j.nucengdes.2004.07.002
  10. J. Paniagua, U.S. Rohatgi, V. Prasad, Modeling of thermal hydraulic instabilities in single heated channel loop during startup transients, Nucl. Eng. Design 193 (1999) 207-226. https://doi.org/10.1016/S0029-5493(99)00156-9
  11. Y. Kozmenkov, U. Rohde, A. Manera, Validation of the RELAP5 code for the modeling of flashing-induced instabilities under natural-circulation conditions using experimental data from the CIRCUS test facility, Nucl. Eng. Design 243 (2012) 168-175. https://doi.org/10.1016/j.nucengdes.2011.10.053
  12. A. Mangal, V. Jain, A.K. Nayak, Capability of the RELAP5 code to simulate natural circulation behavior in test facilities, Prog. Nucl. Energy 61 (2012) 1-16. https://doi.org/10.1016/j.pnucene.2012.06.005
  13. R.P. Martin, B.K. Taylor, Benchmarking assessment of RELAP5/ MOD3 for the low flow and natural circulation experiment, Westinghouse Savannah River Co., Aiken (SC), 1992.
  14. L. Sun, L. Sun, C. Yan, D. Fa, N. Wang, Conceptual design and analysis of a passive residual heat removal system for a 10 MW molten salt reactor experiment, Prog. Nucl. Energy 70 (2014) 149-158. https://doi.org/10.1016/j.pnucene.2013.09.013
  15. K.A. Dittko, M.P. Kirkpatrick, S.W. Armfield, Large eddy simulation of complex sidearms subject to solar radiation and surface cooling, Water Res. 47 (2013) 4918-4927. https://doi.org/10.1016/j.watres.2013.05.045
  16. D.N. Basu, N.D. Patil, S. Bhattacharyya, P.K. Das, Hydrodynamics of a natural circulation loop in a scaleddown steam drum-riser-downcomer assembly, Nucl. Eng. Design 265 (2013) 411-423. https://doi.org/10.1016/j.nucengdes.2013.07.031
  17. R. Gregorig, J. Kern, K. Turek, Improved correlation of film condensation data based on a more rigorous application of similarity parameters,Warme Stoffu bertragung 7 (1974) 1-13. https://doi.org/10.1007/BF01438315
  18. S.S. Kutateladze, Fundamentals of heat transfer, Academic Press, New York, 1963.
  19. W.M. Rohsenow, J.P. Hartnett, E.N. Ganic. Boiling, handbook of heat transfer fundamentals, McGraw-Hill, New York, 1985.
  20. Z. Tao, W. Zenghui, Y. Ruichang, Study on model of onset of nucleate boiling in natural circulation with subcooled boiling using unascertained mathematics, Nucl. Eng. Design 235 (2005) 2275-2280. https://doi.org/10.1016/j.nucengdes.2005.04.003
  21. R. Khodabandeh, R. Furberg, Instability, heat transfer and flow regime in a two-phase flow thermosyphon loop at different diameter evaporator channel, Appl. Thermal Eng. 30 (2010) 1107-1114. https://doi.org/10.1016/j.applthermaleng.2010.01.024
  22. R.D. Chas, Demonstration on intermittent pressure with boiling water, Proc. Phys. Soc. London 35 (1922) 273. https://doi.org/10.1088/1478-7814/35/1/340
  23. J.C. Chen, Correlation for boiling heat transfer to saturated fluids in convective flow, Ind. Eng. Chem. Proc. Design Devel. 5 (1966) 322-329. https://doi.org/10.1021/i260019a023

Cited by

  1. Thermal Energy Processes in Direct Steam Generation Solar Systems: Boiling, Condensation and Energy Storage - A Review vol.6, pp.None, 2016, https://doi.org/10.3389/fenrg.2018.00147