• Title/Summary/Keyword: water chambers

Search Result 164, Processing Time 0.032 seconds

Waterhammer for the In-Line Intake Pumping Station with Air Chamber (에어챔버가 설치된 인라인 취수펌프장에서 수격현상)

  • Kim, Kyung-Yup;Ahn, Cheoul-Hong;Kim, Bum-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.

Effect of Shiitake(Lentinus edodes. p) Mushroom Powder and Sodium Tripolyphosphate on Texture and Flavor of Pork Patties

  • Chun, S.S.;Edger Chambers IV;Delores H. Chambers
    • Proceedings of the Korean Journal of Food and Nutrition Conference
    • /
    • 2004.07a
    • /
    • pp.48-48
    • /
    • 2004
  • Shiitake mushroom contained numerous nutrients, special flavor (lenthionine) and taste. In Asia, they are thought to have numerous medical properties f3r several diseases such as diabetes, anemia, tumors. Phosphates are known to increase hydration and water binding, stabilize meat emulsions, improve juiciness and tenderness, provide mineral supplementation, and maintain flavor of processed meat products. A lexicon f3r describing the texture and flavor of cooked pork patties were developed. (omitted)

  • PDF

Seasonal Change of Rice-mediated Methane Emission from a Rice Paddy under Different Water Management and Organic Amendments (물 관리와 유기물 시용이 다른 논에서 벼 식물체를 통한 메탄 배출의 계절변화)

  • Shin, Yong-Kwang;Lee, Yang-Soo;Ahn, Jong-Woong;Koh, Mun-Hwan;Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • Methane emission was measured in a rice paddy under different water management and organic amendments. Methane emission from planted chambers and unplanted chambers was monitored to evaluate the rice-mediated methane emission. In flooding methane emission from planted chambers with NPK, NPK(+P), was $0.174g\;CH_4\;m^{-2}\;d^{-1}$ while that from unplanted chambers with NPK, NPK(-P), was $0.046g\;CH_4\;m^{-2}\;d^{-1}$ Methane emission from planted chambers with rice straw compost amendment, RSC(+P), was $0.214g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chambers with rice straw compost amendment, RSC(-P), was $0.076g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from planted chambers with rice straw amendment in Fehruary, RS2(+P), was $0.328g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chambers with rice straw amendment in February, RS2(-P), was $0.1g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from planted chambers with rice straw amendment in May, RS5(+P), was $0.414g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chamhers with rice straw amendment in May, RS5(-P), was $0.187g\;CH_4\;m^{-2}\;d^{-1}$. In intermittent irrigation methane emission from NPK(+P) was $0.115g\;CH_4\;m^{-2}\;d^{-1}$, while that from NPK(-P) was $0.041g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RSC(+P) was $0.137g\;CH_4\;m^{-2}\;d^{-1}$, while that from RSC(-P) was $0.06g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RS2(+P) was $0.204g\;CH_4\;m^{-2}\;d^{-1}$, while that from RS2(-P) was $0.09g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RS5(+P) was $0.273g\;CH_4\;m^{-2}\;d^{-1}$, while that from RS5(-P) was $0.13g\;CH_4\;m^{-2}\;d^{-1}$. Methane transport via rice plant under flooding for NPK plot, RSC plot, RS2 plot and RS5 plot was 73.6%, 64.5%, 69.5% and 54.8%, respectively, and mean was 65.6%. Methane transport via rice plants under intermittent irrigation for NPK plot, RSC plot, RS2 plot and RS5 plot was 64.3%, 59.2%, 55.9% and 52.4%, respectively, and mean was 58.0%.

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.

Effects of heat stress on performance, physiological parameters, and blood profiles of early-fattening Hanwoo steers in climate chambers

  • Jun Sik Woo;Na Kyun Lee;Hong Gu Lee;Keun Kyu Park
    • Animal Bioscience
    • /
    • v.37 no.1
    • /
    • pp.142-150
    • /
    • 2024
  • Objective: This study was conducted to assess effects of heat stress on growth performance, physiological parameters, and blood profiles of Hanwoo steers during early-fattening period in climate chambers. Methods: Four Hanwoo steers (body weight, 454.3±10.9 kg; age, 14±0.1 month) were allocated into four levels of temperature-humidity index (THI) in a 4×4 Latin square design for 21 days (pre-adaptation, 7 d; heat stress, 7 d; post-adaptation, 7 d) per period. Experimental treatments were assigned according to THI chart based on National Institute Animal Science (NIAS, 2022): Comfort (25.5℃ to 26.5℃, 60%; THI 73 to 75), Mild (28℃ to 29℃, 60%; THI 77 to 79), Moderate (29.5℃ to 30.5℃, 80%; THI 82 to 84), and Severe (31℃ to 32℃, 80%; THI 85 to 86) in separate climatic controlled chambers. Results: The dry matter intake (DMI) of the formula feed was lower in Severe compared to Mild and Comfort (p<0.05). The DMI of rice straw was the lowest in Severe and lower in Moderate than Comfort and Mild (p<0.05). Both average daily gain and feed conversion ratio of Severe and Moderate were lower than those of Mild and Comfort (p<0.05). Water intake was the highest in Severe and lower in Moderate compared with Comfort and Mild (p<0.05). Heart rate and rectal temperature increased as THI level increased (p<0.05). Glucose was the lowest in Severe and lower in Moderate compared to Comfort (p<0.05). On the contrary, non-esterified fatty acid was the highest in Severe and lower in Moderate compared with Comfort (p<0.05). Blood urea nitrogen of Moderate and Severe were higher than those of Comfort and Mild (p<0.05). Cortisol increased as THI increased (p<0.05). Conclusion: This study demonstrated the negative effects of heat stress on the performance and physiological responses of Hanwoo steers during the early-fattening period. In addition, it is judged that the THI chart for Hanwoo steers of National Institute of Animal Science (2022) was properly calculated.

Continuous Decomposition of Ammonia by a Multi Cell-Stacked Electrolyzer with a Self-pH Adjustment Function (자체 pH 조정 기능을 갖는 다단 전해조에 의한 암모니아의 연속식 분해)

  • Kim, Kwang-Wook;Kim, Young-Jun;Kim, In-Tae;Park, Geun-Il;Lee, Eil-Hee
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • This work has studied the changes of pH in both of anodic and cathodic chambers of a divided cell due to the electrolytic split of water during the ammonia decomposition to nitrogen, and has studied the continuous decomposition characteristics of ammonia in a multi-cell stacked electrolyzer. The electrolytic decomposition of ammonia was much affected by the change of pH of ammonia solution which was caused by the water split reactions. The water split reaction occurred at pH of less than 8 in the anodic chamber with producing proton ions, and occurred at pH of more than 11 in the cathodic chamber with producing hydroxyl ions. The pH of the anodic chamber using an anion exchange membrane was sustained to be higher than that using a cation exchange membrane, which resulted in the higher decomposition of ammonia in the anodic chamber. By using the electrolytic characteristics of the divided cell, a continuous electrolyzer with a self-pH adjustment function was newly devised, where a portion of the ammonia solution from a pHadjustment tank was circulated through the cathodic chambers of the electrolyzer. It enhanced the pH of the ammonia solution fed from the pH-adjustment tank into the anodic chambers of the electrolyzer, which caused a higher decomposition yield of ammonia. And then, based on the electrolyzer, a salt-free ammonia decomposition process was suggested. In that process, ammonia solution could be continuously decomposed into the environmentally-harmless nitrogen gas up to 83%, when chloride ion was added into the ammonia solution.

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

A Cold Flow Experiment for the Incinerator Shape Design (소각로의 형상설계를 위한 냉간유동실험)

  • 류창국;김숭기;최상민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2184-2193
    • /
    • 1994
  • A flow visualization experiment using water-table models was performed. The water-table models simulated the two-dimensional cold flow fields inside the combustion chambers of incinerators. The flow were visualized by small but neutrally bouyant particles photographed by an overhead camera. The experimentally simulated flow fields apparently showed distinct features of two combustion chamber shapes; counter and parallel flow types. The significance of the secondary air injection on the mixing of combustion gases were clearly observed. The effects of the recirculation zones, which were present in the secondary chamber, were discussed by considering the importance of them for optimal combustion.

Variation of Flow conditions in T-type Cooling-Water-Pump Chambers with Increasing Inflows in Intake Canal (유량증가에 따른 T형 취수펌프장내의 흐름변화)

  • Yi, Yong-Kon;Cheong, Sang Hwa;Yoon, Byeong Mo;Kim, Chang Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1424-1428
    • /
    • 2004
  • 본 연구는 유량증가에 따른 T형 취수펌프장내의 흐름상황변화를 수리 및 수치모형실험을 통하여 규명하였다. 수리모형은 1:20의 축척으로 제작되었고 수치모형은 RMA-2를 사용하였다. 수리모형실험은 취수펌프장내의 3차원 흐름현상을 살펴보기에 적절한 것으로 나타났다. 2차원 수치모형은 3차원 흐름현상을 토의하기에는 어려운 점이 있겠지만 경제적으로 여러 가지 상황에 대한 모형실험을 할 수 있는 장점을 이용하기 위하여 취수펌프장내 5D지점에서의 최대유속과 와도, 펌프 장내 최대유속, 냉각수취수로내의 최대유속을 2개의 취수로 공급유량에 대하여 비교하였다.

  • PDF