• 제목/요약/키워드: wastewater flow

검색결과 672건 처리시간 0.029초

고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가 (Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment)

  • 강범희;임경호;이상민
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.

최근(2008-2019년) 하수도통계 자료 분석 기반 국내 하수재이용량 예측 (Recent(2008-2019) trend and expectations in future of the water reuse capacity based on the statistics of sewerage in Republic of Korea)

  • 마정혁;정성필
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.477-487
    • /
    • 2021
  • Due to the global climate change, Korean peninsula is has been experiencing flooding and drought severely. It is hard difficult to manage water resources sustainably, because due to intensive precipitation in short periods and severe drought has increased in Korea. Reused water from the wastewater treatment plant (WWTP) could be a sustainable and an alternative water source near the urban areas. In order to understand the patterns of water reuse in Korea, annual water reuses data according to the times and regional governments were investigated from 2008 to 2019. The reused water from WWTP in Korea has been mainly used for river maintenance flow and industrial use, while agricultural use of water reuse has decreased with time. Metropolitan cities in Korea such as Seoul, Busan, Daegu, Ulsan, and Incheon have been mainly used reused reusing water for river maintenance flow. Industrial water reuse has been limitedly applied recently for the planned industrial districts in Pohang, Gumi, Paju, and Asan. By using the collected annual water reuse data from the domestic sewerage statistics of sewerage, the optimistic and pessimistic future estimations of for future annual water reuse were suggested from 2020 to 2040 on a five year interval for every five years.

초전도 자기분리에 의한 제지폐수의 정수 (Purification of wastewater from paper factory by superconducting magnetic separator)

  • 하동우;김태형;권준모;손명환;백승규;오상수;하홍수;고락길;김호섭;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.342-343
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to purity and recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purity the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purity rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수 (Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator)

  • 하동우;김태형;손명환;권준모;백승규;오상수;고락길;하홍수;김호섭;김영훈;강채훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

MLVSS에 따른 Jet Loop Reactor (JLR)에서 동력량과 공기량이 산소전달률에 미치는 영향 (Effects of Energy Input and Air Flow Rate on Oxygen Transfer Rate at Different MLVSS in a Jet Loop Reactor (JLR))

  • 윤애화;배종훈;임현우;전항배;허태영
    • 대한환경공학회지
    • /
    • 제33권12호
    • /
    • pp.868-873
    • /
    • 2011
  • 산소전달률은 음폐수, 축산폐수 그리고 매립지 침출수와 같은 고농도 폐수처리를 호기성 공정으로 처리할 시 그 성과를 결정하는 아주 중요한 요소이다. 본 논문에서는, Jet Loop Reactor (JLR)를 이용하여 공기유량과 동력량을 운전조건의 변수로 두고 미생물의 농도에 따른 산소소비율(Oxygen uptake rate, OUR)과 물질전달계수(Volumetric mass transfer coefficient, $K_L{\cdot}a$)를 측정하였으며, 산출된 $K_L{\cdot}a$ 값의 결과를 가지고 통계학적인 분석을 통하여 비선형 회귀 모형을 제안하여 보았다. 연구 결과, 미생물 농도를 높게 유지시켜야 하는 고농도 폐수를 적용할 경우에는, 동력량과 공기량은 산소전달률의 중요한 인자이며, 마지막으로 최종 비선형 회귀모형을 동력량과, 공기량 그리고 점성계수의 함수로 나타내보았다.

막 증발법(Membrane Distillation)을 이용한 고농도 하·폐수처리 가능성 연구 (Feasibility study on the application of membrane distillation process to treat high strength wastewater)

  • 김세운;이동우;민경진;조진우
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.261-269
    • /
    • 2015
  • In this study, we applied a membrane distillation process to investigate a feasibility of treating a wastewater with high concentration of organic matters including nitrogen and phosphorus. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$ and porosity of 75%. The installation was direct contact type where the temperature difference between a feed and permeate side was controlled to have a range from 20 to $60^{\circ}C$. We observed a flux variation and a concentration changes of COD, $PO{_4}^{3-}$-P, $NH_4{^+}$-N and conductivity of feed side as well as permeate side with various temperature differences (20 to $60^{\circ}C$), cross flow velocities (0.09 to 0.27 m/s) through the module, and pH (6.6 to 12.0) of the feed that has the initial concentration of COD about 1,000 mg/L, total nitrogen 390 mg/L, total phosphorus 10 mg/L, conductivity of $7,000{\mu}s/cm$. The results showed that the average flux was ranged from 4 to $40L/m^2/hr$ which was almost similar with the flux of NaCl and deionized water used as a feed solution. The lowest flux was obtained at the operating condition with the temperature difference of $20^{\circ}C$ and cross flow velocity of 0.09 m/s while the highest one was measured with $60^{\circ}C$ and 0.27 m/s. Above 99% of COD and $PO{_4}^{3-}$-P in the feed could be rejected regardless of an operating condition. However, the removal rate of ammonium nitrogen was varied from 64 to 99% depending on the pH of feed solution.

하수처리시설에서 인 회수공정의 도입 가능성에 대한 실증적 검토 (Empirical Study on Applicability of Phosphorus Recovery Process in Wastewater Treatment Plant)

  • 박나리;장향연;임현만;안광호;김원재
    • 대한환경공학회지
    • /
    • 제39권1호
    • /
    • pp.40-49
    • /
    • 2017
  • 본 연구에서는 경기도 고양시 소재 I 수질복원센터의 공정별 유량과 총인(TP) 농도를 활용하여 2015년도 기준 TP 물질수지도를 작성하고, 이를 분석하여 하수처리시설에서 인(P)을 회수할 수 있는 최적의 단위공정을 실증적으로 선정하고자 하였다. 인 회수공정의 도입 가능성을 평가하기 위하여 유량, TP농도, TP부하량 및 SS에 대한 정량적 지표를 제안하는 한편, 이를 I 수질복원센터에 적용하였다. 또한 I 수질복원센터의 탈수여액을 대상으로 인 회수공정의 도입 가능성에 대한 기초실험을 실시하였다. TP 물질수지를 분석한 결과, 하수처리장 유입수에 비해 유량은 1/16로 적지만 TP농도는 약 78배, TP부하량은 4.8배에 달하는 반류수 계통을 대상으로 인을 회수하는 것이 하수처리시설 전체의 TP부하를 저감하는데 유효한 것으로 나타났다. 반류수 계통의 단위공정들을 대상으로 본 연구에서 제안한 정량적 지표를 활용하여 인 회수공정의 도입 가능성을 상세히 평가한 결과, (잉여농축조 상징액+잉여저류조 월류수) 또는 탈수여액이 적합한 것으로 나타났다. 한편, TP농도가 141.5 mg/L에 달하는 탈수여액을 대상으로 결정화에 의한 인 회수 기초실험을 실시하였다. 탈수여액의 pH를 10으로 조정한 후 칼슘이온($Ca^{2+}$)을 각각 250, 500, 1000 mg/L씩 주입하여 완속교반을 실시하였다. 기초실험 결과 탈수여액 중의 $PO_4-P$ 및 TP를 95% 이상 제거할 수 있는 것으로 나타나 인 회수공정의 도입 가능성이 확인되었다.

배수구역별 누수관리를 위한 야간유량성분 특성연구 (Study on the characteristics of night flow components for leakage management in district metered area)

  • 구자용;장광호;김민철
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.871-879
    • /
    • 2009
  • The Korea has high population density, so the precipitation per capita is only one tenth to world average. The water resource in Korea is insufficient. But the leakage in the water distribution system is about 25%, and it is lower than other countries where water utilities are managed well. The pipelines' management also is getting worse because the leakage in the pipelines lower the ground density surrounding pipes. So, managing the leakage in the water distribution system is very important in the view of increasing the water resources and doing the efficient management of the pipeline system. Accordingly this study aimed to conduct a cause-analysis with scientific approaches considering key local factor related to water loss of distribution system and derive better performance indicators which are able to evaluate the real state of water loss management reasonably. Also this research aimed to develop a methodology capable of judging condition of infrastructure of water distribution system.

20~50mm 수도계량기 미감지율 조사분석 (Investigation on Under-registration of 20 mm to 50 mm Water Meters)

  • 안재찬;하성호;박태준;김석정;구자용
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.582-594
    • /
    • 2005
  • The under-registration of water meters of 20mm to 50mm in diameter, installed in Seoul city, was estimated by random sample method. The sample sites and sampled meters were selected for the measurements of flow rates and accuracy tests, respectively. The measurement of flow rates was conducted for 20mm to 50mm meters for about 20 days per site using flow meters and data loggers. The under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was observed as 3.96%, 1.10%, 2.47%, 4.04%, and 1.04%, respectively. The under-registration might be increased more or less as malfunction and failure of the sampled meters was not considered. In this study the under-registration of 20mm, 25mm, 32mm, 40mm, and 50mm meters was accurately estimated on the basis of the investigation data. The estimation of under-registration of water meters, one of the basic figures in water industry, contributed to accurate calculation of leakage, water supply and consumption, and strategic planning to reduce the unaccounted-for water.

자가발전효율 향상을 위한 유수관내 블레이드 형상의 모델링 및 해석 (Modeling of Blades to Enhance Self-Power Generation in Pipe Flow)

  • 여인환;김도윤;백종후;이영진;신민철;박재우
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.277-285
    • /
    • 2010
  • We examined the optimal shape of blades and efficiency of a self-power generator when the self-power generator using flow of the water in pipe as the power source was installed. Selected factors were the shape of blades, the number of blades, pitch angle, and the existence of separator. GAMBIT2.4 was used as a modeling program, FLUENT6.3, which is computational fluid dynamics simulation program, was used as an analytical model. In the case of a viscous model, k-epsilon standard model was chosen. As a result, when the number of blades was increased, the efficiency and maximum moment were enhanced slightly. The pitch of blades went up, and maximum moment was also increased. The optimal pitch of blade was 62.5 degree and the efficiency was increased by 30%. The efficiency was also increased when a separator was installed.