• Title/Summary/Keyword: waste load

Search Result 286, Processing Time 0.026 seconds

The Evaluation of Scum Recyclability from Waste Sludge in Linerboard Mills (라이너지 제조공정 탈수 슬러지의 scum 재이용 가능성 평가)

  • Kang, Kwang-Ho;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.3
    • /
    • pp.42-47
    • /
    • 2008
  • For the purpose of reduction of production cost in the industrial papermaking process, the use of waste paper has been more and more increased as a fibrous raw material, and the closed system of white water became closed more than ever. "Scum" indicates the floated sludge by a flotation during primary wastewater treatment process in paper mills. If the scum is used as the raw material, it could reduce both the raw material and solid waste treatment cost with even small quantity. In this study, the element survey and the toxicity measurement was carried out for recycling scum. A load factor of stock preparation process in paper mills was measured by somerville screen. Physical properties of paper sheet containing the accepted scum from the stock of AOCC or KOCC were evaluated. The result of this study shows that recycling scum has potential to be used in paper making system. It also might be able to reduce the required energy used by the pressing or drainage process, the raw material cost, and solid waste treatment cost due to the recycling of scum.

Flexural Behavior of Polymer Mortar Permanent Forms Using Methyl Methacrylate Solution of Waste Expanded Polystyrene

  • Bhutta, M. Aamer Rafique;Tsuruta, Ken;Ohama, Yoshihiko
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.35-39
    • /
    • 2008
  • This experimental study examines the applicability of polymer mortar permanent forms using a methyl methacrylate (MMA) solution of waste expanded polystyrene (EPS) to develop effective recycling processes for the EPS, referring to the flexural behavior of a polymer-impregnated mortar permanent form with almost the same performance as commercial products. An MMA solution of EPS is prepared by dissolving EPS in MMA, and unreinforced and steel fiber-reinforced polymer mortars are mixed using the EPS-MMA-based solution as a liquid resin or binder. Polymer mortar permanent forms (PMPFs) using the EPS-MMA-based polymer mortars without and with steel fiber and crimped wire cloth reinforcements and steel fiber-reinforced polymer-impregnated mortar permanent form (PIMPF) are prepared on trial, and tested for flexural behavior under four-point (third-point) loading. The EPS-MMAbased PMPFs are more ductile than the PIMPF, and have a high load-bearing capacity. Consequently, they can replace PIMPF in practical applications.

Problems in Strength Characteristics of Recycled Waste Concrete (폐콘크리트 재활용에 있어서 강도특성상의 문제점)

  • 김광우;연규석;이병덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.44-49
    • /
    • 1992
  • Selected strength characteristics of recycled concrete using crushed waste concrete were compared with those of conventional concrete using natural aggregate. Compressive strength, bonding at the interface between recycled aggregate and fresh mortar, strain and deflection under three-point bending were evaluated. Recycled concrete, in general, showed lower compressive strength, lower edlastic modulus, higher stain and higher deflection under the same loading level, compared with those of conventional concretes. However, the strength retaining ratios of recycled concretes were higher than those of conventional concretes. The compressive strength which is one of the most important load carrying capacities of concrete should be improved for successful re-use of waste concrete in structural concrete.

Effect of Fuel Injection Pressure and Timing on the Combustion and Emission Characteristics in a Compression Ignition Engine under Low Load Condition Fueled with Waste Cooking Oil Biodiesel (폐식용유 바이오디젤을 이용한 압축착화엔진의 저부하 영역에서 연료의 분사 압력과 분사 시기가 연소 및 배기특성에 미치는 영향)

  • Hwang, Joonsik;Jung, Yongjin;Bae, Choongsik
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.313-316
    • /
    • 2012
  • In this study, the combustion and emission characteristics of waste cooking oil biodiesel was investigated. The fuel was injected from 5 CAD (Crank angle degree) ATDC (After top dead center) to -60 CAD ATDC by 5 CAD with 800 bar and 1600 bar injection pressure. Generally, the hydrocarbon, carbon monoxide and smoke emissions from biodiesel fuel were lower than the emission levels of diesel fuel. However, the emission characteristic of biodiesel got worse than diesel when the fuel was injected earlier than -30 CAD ATDC. $NO_x$ emission from biodeisel was higher than diesel fuel in all experimental conditions.

  • PDF

A Study on Optimum Application of Unutilized Energies in the Jeju Environment Facility (제주지역 환경시설지구의 미활용 에너지 최적 활용방안에 관한 연구)

  • Kang, B.C.;Park, Y.C.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.9-15
    • /
    • 2007
  • This paper provides a methodology for the optimization of waste heat usage in Jeju Province. The incineration plant was considered as heat source and the food garbage plant and the youth hostel were selected as heat sink of this study. The distribution of the reusing energy in incineration plant is decide by load analysis and numerical calculation of the operational methodology. The main objective of this study is on the reduction of the fuel costs and reuse of waste heat. As the results, the efficiency of the incineration plant and two heat sink, the food garbage plant and the youth hostel, are improved and economical suggestions are proposed through the optimization analysis.

  • PDF

Bearing Capacity of Waste Landfill Reinforced by Geosynthetics (토목섬유로 보강된 폐기물 매립지반의 지지력 특성)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.39-46
    • /
    • 2007
  • Many industrialized countries of the world have many problems about the reuse of waste landfill area because the increase of terminated waste disposal landfill. Especially, the effective use of the terminated waste disposal landfill nearby the urban area has been demanded, because of the lack of the usable land. However, the reuse of terminated waste disposal landfill site is needed an adequate stabilization of ground for increasing the bearing capacity and reduce the allowable settlement for the given structure. This study is to evaluate the applicability of geosynthetics for the increment of bearing capacity of solid waste landfill ground. The in-situ cyclic plate loading tests were performed to determine the dynamic and static behaviors of reinforced ground with geosynthetics. Four series of test were conducted with variations of geosynthetics, number of geogrid layer. Based on the cyclic plate load test results, the bearing capacity ratio, subgrade modulus of ground, and the elastic rebound ratio were determined.

  • PDF

Generation of Food Waste from Different Sources and Its Composting Measures at the Apartment Complex (배출원별 음식물 쓰레기 발생 특성 및 아파트 단지에서의 퇴비화 방안 (대전 및 충청남도 지역을 중심으로))

  • Kang, H.;Lee, O.L.;Kim, J.W.;Hur, H.W.;Han, S.H.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.53-66
    • /
    • 1998
  • This study was carried out to investigate the typical composition of food waste from municipal solid wastes (MSW) and unit food waste generation rates from different sources in the model cities and to study the food waste management system from unit household to composting facilities. The annual average food waste composition of MSW was determined as 49% in Taejon and 52% in Chungnam Province, respectively. No big difference in food waste composition was found among the different sources. Since the paper waste generally occupied the half of food waste, over 75% of MSW was found to be compostable or biodegradable. Per capita food waste generation rate, 200~250g/capita day was determined by the direct measurement from 32 households, while 380g/capita day for Chungnam Province and 400 g/capita day for Taejon were estimated by the load count analysis In the sanitary landfills. This difference means people contribute generating food waste at outside house approximately twice as much as that at inside house. Per capita food waste generation rates from several sources were determined as follows; 166~215g/capita day at municipalities, 400g/visitor day at a first class hotel, 170g/student day at a university restaurant. Food waste generation from restaurant was strongly dependant upon it's level or quality; 670g/capita day at the high level restaurant, 190g/capita day at the middle class and 60 g/capita day at the lower class restaurant. The food waste reduction rate in a In situ fermentor showed 30~40g/kg day.

  • PDF

Utilization of biofilter/photo-catalytic reactor system for the simultaneous treatment of hydrogen sulfide and toluene from waste-air

  • Lim, Kwang-Hee;Ping, Wang Zhi;Lim, Dong-Joon;Lee, Eun-Ju
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.287-292
    • /
    • 2005
  • Transient behavior of biofilter/photo-catalytic reactor system was observed to eliminate both hydrogen sulfide and toluene from waste air at its four sampling ports. The biofilter was packed with a equivolume mixture of granular activated carbon(GAC) and compost as packing media on which Thiobacillus sp. IW and Burkholderia cepacia G4 were inoculated and were fixed. The biofilter/photo-catalytic reactor system was run for eight stages of operation under various operating conditions. As a result the removal efficiencies of hydrogen sulfide and toluene began to decrease from 100% after the inlet loads of hydrogen sulfide and toluene surpassed ca. 100 $S-g/m^{3}/h$ and $161g/m^{3}/h$, respectively, and were rapidly decreased to 60% after the inlet loads of hydrogen sulfide and toluene were increased to 200 $S-g/m^{3}/h$ and $644g/m^{3}/h$, respectively.

  • PDF

Generation Efficiency and Thermal Performance of a Thermoelectric Generator with a High Power Electronic Component (고전력 전자소자에서 열전생성기의 생성효율과 열적성능)

  • Kim, Kyoung-Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • This paper reports the generation efficiency and the thermal performance of a thermoelectric generator (TEG) harvesting energy from the waste heat of high power electronic components. A thermoelectric (TE) model containing thermal boundary resistances is used to predict generation efficiency and junction temperature of a high power electronic component. The predicted results are verified with measured values, and the discrepancy between prediction and measurement is seen to be moderate. The verified TE model predicts generation efficiencies, junction temperatures of the component, and temperature differences across a TEG at various source heat flows associated with various electrical load resistances. This study explores effects of the load resistance on the generation efficiency, the temperature difference across a TEG, and the junction temperature.

Studies on Environmental Impact of Pulp and Addtives in Liner Papermaking

  • Seo, Jin-Ho;Kim, Hyoung-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.441-444
    • /
    • 2006
  • A lot of water is using in the paper mill for dilution, washing, sealing, and other process operation. As the regulation of water environment has been more tightened than ever before, water management in the paper mill becomes the most important task. Topics on reducing fresh water and increasing recycling water have been studied. Further, an interest in zero-effluent system has been increased. The pH of waste water in paper mill is usually weak acidic or neutral. The waste water in the paper mill includes water insoluble organic materials that are not easy to be dissolved in the water, inorganic materials that never react with water and chemical additives that are used to recycled fiber. This study investigated on the effect of various materials used in paper mill on COD. This data could be used to control the environmental load in paper mill. COD caused by raw materials and NBDCOD (Non Bio Degradable COD) after the activated sludge process are investigated in this study. Results obtained in this study can be used in a simulation program designed to control environmental load in the paper mill.

  • PDF