• 제목/요약/키워드: wall voltage

검색결과 206건 처리시간 0.028초

Wall Voltage Transfer Characteristics according to Address Bias Voltage

  • Lee, Y.M.;Jeong, D.C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.601-604
    • /
    • 2007
  • In this paper, we report the wall voltage transfer characteristic between sustain electrodes according to the address bias voltage in a 3-electrodes surface discharge type ac PDP by the VT close curve measurement technique. The result shows the change of wall voltage according to the gap voltage variation depends on the address bias voltage.

  • PDF

A Study on the Temporal Behavior of the Wall Voltage in a surface-type AC panel

  • Kim, Jung-Hun;Lee, Jun-Hak;Choi, Young-Wook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.175-176
    • /
    • 2000
  • Electric fields and the wall voltages in a surface-type AC PDP cell were measured using a Laser Induced Fluorescence Spectroscopy. For the condition of He 100Torr, 200V sustain voltage and 50kHz sustain frequency, the wall voltage dropped from about 50V to about -75V within $1{\mu}sec$ after the main discharge. And the wall voltage decreased with the rate of $10.8V/{\mu}sec$ due to the accumulation of the space charges after $1{\mu}sec$. But when the operating pressure was 40Torr, it increased with the rate of $4.5V/{\mu}sec$ because the diffusion effect of the wall charge on MgO surface was more dominant than the accumulation effect of the space charges. During the pulse-off period, the wall voltage decreased slightly due to the diffusion of the wall charge. When the sustain voltage was 250V, the self-erasing discharge occurred, and the absolute value of the wall voltage decreased rapidly just after the pulses were off, which was caused by the accumulation of the charges generated by the self-erasing discharge.

  • PDF

AC PDP의 벽전하 분포를 이용한 유지 펄스의 전압 마진 결정 (Decision of the Margin of the Sustain Voltage Based on the Wall-Charge Distribution)

  • 하영석;권오경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.77-80
    • /
    • 2000
  • This paper describes a new method to decide the margin for the sustain voltage of AC PDPs based on the wall-charge distribution. We model the discharge cell and measure the wall-charge when sustain pulses are applied to the AC PDP. The measured wall-charge distribution informs us of the voltage forming the maximum wall-charge which should be chosen as the sustain voltage.

  • PDF

Measurement of Wall Voltage in Reset Discharge of AC PDP

  • Park, K.D.;Jung, Y.;Ryu, C.G.;Choi, J.H.;Kim, S.B.;Cho, T.S.;Oh, P.Y.;Jeon, S.H.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.722-725
    • /
    • 2003
  • In AC plasma display, it is very important to quantify the wall voltage induced by the wall charge accumulated on the dielectric surface. If we know the quantities of the wall voltage in each period of every sequence; reset period, address period and sustain period, then it helps us to design the optimal driving waveform for high efficiency plasma display. We develop a new method to measure the wall voltage with VDS (Versatile Driving Simulator) system. From this method the wall voltage induced by a wall charge profiles just after the reset discharge of every cells in plasma display panel can be investigated and analyzed successfully. It is noted that the wall voltage profiles are influenced by the space charge and then they are stabilized as time goes by. It is also noted that both the remaining wall charge at the previous sequence and space charges contribute to wall voltage quantities just after the reset discharge. It is noted that the wall charges contribute dominantly after a few hundreds microseconds, while the space charges have been decayed within 100 ${\mu}s$ just after the reset discharge.

  • PDF

Influence of reset pulse form on electrical characteristics in AC-PDP

  • Cho, T.S.;Ko, J.J.;Lee, C.W.;Cho, G.S.;Choi, E.H.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.159-161
    • /
    • 2000
  • After the square type reset pulse, the condition of remaining wall charge has been experimentally investigated in AC-PDP with VDS (Versatile Driving Simulator) system, in which arbitrary driving waveform and sequence can be used. After the self-discharge process, almost wall charges are eliminated. But some wall charges are not and its quantity is dependent on the voltage of the reset pulse. When the voltage of the reset pulse is growing, its quantity is decreased. But if the voltage of the reset pulse is above 300V, the wall voltage due to remaining wall charge is constant and its value is found out 6V. Also it is found that its polarity is always same with the one made by the reset pulse. It means that the polarity is not changed by the self-discharge.

  • PDF

The Influence of Xe Content on Wall Voltage Transfer Behavior

  • Baik, Bong-Joo;Choi, Kwang-Yeol;Min, Wong-Kee;Hong, Mun-Heon;Lee, Dong-Woo;Min, Byung-Kuk;Kim, Weo-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1555-1558
    • /
    • 2008
  • Various approaches were undertaken by major PDP makers in order to improve the luminous efficacy of the plasma discharge cells. There have been many reports that state that using a high Xe content PDP is one of the most promising key technologies available to improve the luminous efficacy. In the case of the higher Xe content panel, the higher address and sustain voltage were needed to drive the panel under the same reset condition. In this study, a variety of Xe content panels were investigated in order to examine wall voltage transfer behaviors. The transferred wall voltage status after addressing discharge at the same driving condition was analyzed by comparing Vt close curve of high and low Xe content panels. Through this analysis of Vt close curve difference, the driving waveform of a high Xe panel was quantitatively adjusted Under the same address voltage condition, results showed that the amount of the transferred wall voltage and Vt close curve after addressing discharge was matched for the first sustain discharge. Taking these results into consideration, we conclude that the driving waveform for different Xe content panels could be designed for the desired addressing discharge condition and the wall voltage state of the cell could be quantitatively controlled and measured through these approaches.

  • PDF

Some Micro-discharge Characteristics of the cells in ac-PDP

  • Son, Jin-Boo;Lee, Sung-Hyun;Lee, Dong-Hyun;Kim, Young-Dae;Cho, Jung-Soo;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.103-104
    • /
    • 2000
  • Voltage transfer curves have been used for analyzing the micro-discharge characteristics of cells in ac-PDP. This paper deals with the effect of working gas species, pressure and frequency of applied voltage on the micro-discharge characteristics. Using the mixture gases of He+Xe or He+Ne+Xe, wall voltage steeply varied compared with only He gas, and also voltage margin increased. Discharge voltage and voltage margin increased with increasing Xe percentage, and also wall voltage more steeply varied. In addition, the variation of effective wall capacitance which is significantly dependent on the discharge strength is discussed.

  • PDF

AC-PDP특성평가를 위한 전압전달곡선 계측에 관한 연구 (Measurement of Voltage Transfer Curve in AC PDP)

  • 손진부;이성현;김동현;김영대;조정수;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.395-398
    • /
    • 1999
  • In ac PDP(plasma Display Panel), the discharge characteristics is very important to display clear images. In this paper, we have studied the measurement of voltage transfer curves which show the discharge characteristics in AC PDP. The change of the effective wall capacitance during a discharge is also studied. These depend on lateral spreading of charge distribution and the strength of the discharge. As a parameter of the frequency, we observed the effects of the frequency in voltage transfer curves and in effective wall capacitance changes. As frequency increases, minimum sustain voltage and firing voltage decrease. In upper region of gap voltage the chance of the effective wall capacitance is independent of frequency.

  • PDF

전계제한테와 측면 유리 절연층을 사용한 고내압 소자의 항복 특성 연구 (A Study on the Breakdown Characteristics of High Voltage Device using Field Limiting Ring and Side Glass Insulator Wall)

  • 허창수;추은상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1072-1074
    • /
    • 1995
  • Zinc-Borosilicate is used as a side insulastor wall to make high breakdown voltage with one Field Limiting Ring in a p-n junction. It is known that surface charge can be yield at the interface of Zinc-Borosilicate Glass/Silicon system. When the glass is used as a side insulator wall, surface charge varied potential distribution and breakdown voltage improved more than 660V without using more FLR.

  • PDF

Influence of Sustain Voltage on Wall Charge and Wall Voltage Characteristics in AC-PDPs

  • Kim, T.Y.;Cho, T.S.;Kim, S.S.;Cho, D.S.;Kim, J.G.;Ahn, J.C.;Jung, Y.H.;Lim, J.Y.;Jung, J.M.;Ko, J.J.;Kim, D.I.;Lee, C.W.;Seo, Y.;Cho, G.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.119-120
    • /
    • 2000
  • Influences of sustain voltage on wall charges and wall voltages are experimentally investigated in surface AC plasma display panels(AC-PDPs), in which electrode gap and width are $80\;{\mu}m$ and $270\;{\mu}m$, respectively. The filling gas is Ne-Xe gas mixture, and total pressures 300 Torr. Also it is found that the more amount of Xe mixing ratio makes the less wall charge and voltage for sustain voltage ranged from 140 V to 222 V. The response time has been delayed by adding a small amount of Xe to Ne in comparison with that without Xe. It is also found that the wall charge and voltage are reduced by adding a small amount of Xe to Ne in comparison with those without Xe.

  • PDF