A Study on the Temporal Behavior of the Wall Voltage in a surface-type AC panel

  • Kim, Jung-Hun (Plasma Lab. SoEE., College of Engineering, Seoul National University) ;
  • Lee, Jun-Hak (Plasma Lab. SoEE., College of Engineering, Seoul National University) ;
  • Choi, Young-Wook (Korea Electrotechnology Research Institute) ;
  • Whang, Ki-Woong (Plasma Lab. SoEE., College of Engineering, Seoul National University)
  • Published : 2000.01.13

Abstract

Electric fields and the wall voltages in a surface-type AC PDP cell were measured using a Laser Induced Fluorescence Spectroscopy. For the condition of He 100Torr, 200V sustain voltage and 50kHz sustain frequency, the wall voltage dropped from about 50V to about -75V within $1{\mu}sec$ after the main discharge. And the wall voltage decreased with the rate of $10.8V/{\mu}sec$ due to the accumulation of the space charges after $1{\mu}sec$. But when the operating pressure was 40Torr, it increased with the rate of $4.5V/{\mu}sec$ because the diffusion effect of the wall charge on MgO surface was more dominant than the accumulation effect of the space charges. During the pulse-off period, the wall voltage decreased slightly due to the diffusion of the wall charge. When the sustain voltage was 250V, the self-erasing discharge occurred, and the absolute value of the wall voltage decreased rapidly just after the pulses were off, which was caused by the accumulation of the charges generated by the self-erasing discharge.

Keywords