• 제목/요약/키워드: wall type system

검색결과 561건 처리시간 0.022초

RC 벽식 아파트의 손상 제어를 위한 PC 비내력벽 시스템의 실험적 평가 (Experimental Evaluation of PC Non-Bearing Wall System for the Damage Control of RC Wall Type Apartments)

  • 문교영;김시윤;김승직;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권4호
    • /
    • pp.77-84
    • /
    • 2019
  • This study introduces a newly developed PC non-bearing wall system to prevent the damage of RC wall-type apartments that have been heavily damaged by the 2017 Pohang Earthquake. In order to evaluate the performance of the developed PC non-bearing wall system, a static cyclic test is conducted. The prototype of test specimen is from the RC wall-type apartment which has been severely damaged by the 2017 Pohang Earthquake. The specimen with the conventional non-bearing wall system showed the similar damage of RC wall type apartment suffered from the Pohang Earthquake. In case of the specimen with the developed PC non-bearing wall system, cracks and damages were not transmitted between the walls due to the seismic slit and there were almost no cracks in the non-bearing walls. Therefore, the proposed non-bearing wall system, separated from the structural walls, could prevent spreading cracks to bearing walls and make it possible to effectively control damage due to earthquake loads.

전면판의 연속성이 보강토체의 안정성에 미치는 영향 (The Role of Wall Facing on the Stability of Reinforced Soil Wall)

  • 임유진;정종홍
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.465-472
    • /
    • 1999
  • A small scale model reinforced soil wall was constructed in a laboratory to investigate role of the wall facing and the effect of construction sequence on the wall. A panel type facing system and a block facing system are introduced for test. These two different types of facing adapt different construction procedure. The model wall is built with geogrid reinforcement, sand, and the facings on rigid surface. The model wall is instrumented with earth pressure gauges, LVDTs, and strain gauges. It is found in this study that the reinforced soil wall system built with geogrids and panel type facing system be the safest reinforced soil wall ever compared to the block type facing. Thus, it is recommended that study for the wall system be necessary for further wide usage in the future.

  • PDF

기둥식 벽체 거푸집 시스템 개발에 관한 실험적 연구 (An Experimental Study on the Development of Unit Column Wall Form System Using (Focusing on the Lateral Pressure))

  • 강창수;이한승;태성호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.507-510
    • /
    • 2005
  • Euro form which constructs the present RC structures is used widely by the form method of construction of a wall type structure had much consumption of the human power and equipments by the assembly and the demolition, and the complement was required according to demerit with much leakage of cement paste by the form joint, so it developed the new pillar type form system. On the study, in order to consider the modification characteristic by lateral pressure which does the influence most important for the new developed pillar type form system performance, research of a paper manufactured a miniature wall form model, and advanced performance evaluation focusing on lateral pressure. Moreover, lateral pressure evaluation of a new style system was actually gone on through the on-site experiment about a part of wall type srutcture spot for a model experiment and its result on the foundation which is the purpose in evaluating on-site application possibility propriety at the foundation time of wall type concrete structure construction of a pillar type form system.

  • PDF

Shear Performance of Hybrid Post and Beam Wall System Infilled with Structural Insulation Panel (SIP)

  • Shim, Kug-Bo;Hwang, Kweon-Hwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권5호
    • /
    • pp.405-413
    • /
    • 2010
  • A hybrid post and beam shear wall system with structural insulation panel (SIP) infill was developed as a part of a green home 'Han-green' project through post and beam construction for contemporary life style. This project is on-going at the Korea Forest Research Institute to develop a new building system which improves Korean traditional wet-type building system and stimulates industrialized wood construction practice with pre-cut system. Compared to the traditional wet-type infill wall components, the hybrid wall system has benefits, such as, higher structural capacity, better thermal insulation performance, and shorter construction term due to the dry-type construction. To build up the hybrid wall system, in previous, SIP infill wall components can be manufactured at factory, and then inserted and nailed with helically threaded nails into the post and beam members at site. Shear performance of the hybrid wall system was evaluated through horizontal shear tests. The SIP hybrid wall system showed higher maximum shear strength, initial stiffness, ductility, yield strength, specified strength, and the specified allowable strength than those of post and beam with light-frame wall system. In addition to this, the hybrid wall system can provide speedy construction and structural and functional advantages including energy efficiency in the building system.

벽식구조 공동주택의 바닥충격음 개선에 대한 연구 (A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment)

  • 김선우
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

설문조사를 통한 장수명주택의 경량벽체 시공성 사후평가 (Post Evaluation on the Constructibility of the Lightweight Wall in Long Life Housing through Interview Survey)

  • 이학주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.188-189
    • /
    • 2014
  • Recently, structural system of apartment building is changing from wall type to column type to accommodate various life styles of residents in Korea. Reinforced-concrete bearing wall structures have been mainly used in apartment construction since 1980's. It is impossible to remove the bearing wall in case of remodeling a house, so that the lightweight wall is needed to apply to the column type structure of the Long Life Housing. Therefore, the purpose of this study is to evaluate the construction performance of the wall. Constructibility reviews are performed throughout interview survey from builders who charge with managing the construction of the lightweight wall in field. This paper present that constructor prefer the bearing wall rather than the lightweight wall because of the schedule delay, difficulty of management, and lack of skilled labor. The results indicate what we should improve on the lightweight wall from now on.

  • PDF

커튼월의 공법 및 조달 유형에 따른 SCM 적용방안 (Application of Supply Chain Management Concept to the Various Types of Curtain Wall Construction)

  • 문우경;윤수원;김예상;진상윤;박지훈
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.612-615
    • /
    • 2004
  • 오늘날 뛰어난 시공성과 경제성으로 인해 수많은 건설 프로젝트에서 커튼월이 사용되고 있으며 특히 국내 초고층 프로젝트의 커튼월 공사는 전체 Life-cycle 상의 건축설계, 커튼월 선계, 제작, 조달, 시공, 유지관리의 모든 단계에서 다양한 주체들이 관여하는 공종으로 주요 관리 대상이 되었다. 기존의 관리방식은 Life-cycle의 각 단계별 관리에 초점을 맞춤으로써 비용 및 공기 증가, 생산성 저하, 풀질 퍼하 등의 문제가 빈번히 발생하고 있는 실정으로 이를 해결하기 위하여 공급사슬관리(Supply Chain Management)를 적용한 통합관리가 필요하다. 이에 본 연구는 커튼월 공사 전체 Life-cycle 관리에 대해 SCM 개넘을 적용하기 위해 커튼월의 방법 및 조달유형에 따라 분류되어진 Sick system, Semi-unit system, Unit-system, Panel system 커튼월의 프로세스를 분석하고 SCM 관전에서 각 프로세스의 조직, 정보, 생산 관점에서 차이점을 규명하고 각각에 대한 SCM의 적용방안을 제시하였다.

  • PDF

안와 외벽 골절의 분류와 임상적 의의 (Classification of the Lateral Orbital Wall Fracture and Its Clinical Significance)

  • 조필동;김형석;신극선
    • Archives of Plastic Surgery
    • /
    • 제35권5호
    • /
    • pp.553-559
    • /
    • 2008
  • Purpose: The lateral orbital wall fractures have been previously classified by some authors. As there are some limitations in applying in their own classifications, we hope to present a refined classification system of the lateral orbital wall fracture and to identify the correlation between the specific type of the fracture and clinical diagnosis. Methods: The facial bone CT scans and medical records of 78 patients with the lateral orbital wall fractures were reviewed in a retrospective manner. The classification is based on the CT scan. In type I, the fracture and its segments are away from the lateral rectus muscle and in type II, they are next to or slightly pushing the muscle in axial CT scan. In type III, the fracture segments compress and displace the longitudinal axis of the muscle or the optic nerve in axial view of CT scan. Type IV fracture includes multiple fractures found around the orbital apex or optic canal in coronal view of CT scans of the type I and type II fractures. Results: The most common fracture pattern was type I(43.6%), followed by type IV(29.5%), type II(20.5%), and type III(6.4%). As diplopia and restriction of extraocular muscles were found in type I and II fractures, severe ophthalmic complications such as superior orbital fissure syndrome, orbital apex syndrome, and traumatic optic neuropathy were found in type III and IV fractures almost exclusively. Conclusion: We propose an easy classification system of the lateral orbital wall fracture which correlates closely with ophthalmic complications and may help to make further treatment plan. In Type III and IV fractures, severe ophthalmic complications may ensue in higher rates, so early diagnosis and treatment should be performed.

A Study on Plan Structure Types and Characteristics of Wall Formation in Art Museum Exhibition Spaces

  • Lee, Jong-Sook
    • Architectural research
    • /
    • 제13권3호
    • /
    • pp.3-10
    • /
    • 2011
  • The Characteristics of space are determined by several factors; however, the element that determines the physical characteristic of floors, walls, and ceiling is the structure. This study constructs a wall to analyze the direct effect that the layout of an exhibition wall has on the element of the wall followed by the structural process and visibility of descriptive analysis and examples of art museums that the shift from a perceptional wall to an experiential wall affected circulation. For elements and formation methods of the wall, first, it is made up of open and closed type exhibition spaces, and it can give abundance in qualitative space rather than a quantitative aspect. Secondly, the directivity of space changes according to the development of the visible axis, thus, directly affects the change in visibility. Thirdly, the difference between spatial structure and visual structure is the difference between the visual axis and spatial structure. The wall formation type followed by the combination method, the simple visible structure, which is the type that possesses the simple combination (Room, Zone, Cluster), repeatedly uses the same size of units of space that is orderly and has few spatial axes and the classification of simple type and simple cluster type, which has few visible axes, also exists. Also, with the complex structure of the maze type it displays the reiterated form of the cluster, which is the space with disorderly combination and has much visible axes and spatial axes. Also, these can be divided into three types: 1) Maze Cluster Type, 2) Cross Road Type, and 3) Open Flexible Type. These wall types lead the various changes in circulation, and even each of the arrangement qualities of the exhibitions should be researched according to its exhibition place type.

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.