• 제목/요약/키워드: wall of wind

검색결과 342건 처리시간 0.03초

Numerical study on stability and deformation of retaining wall according to groundwater drawdown

  • Hyunsung Lim;Jongjeon Park;Jaehong Kim;Junyoung Ko
    • Geomechanics and Engineering
    • /
    • 제33권2호
    • /
    • pp.195-202
    • /
    • 2023
  • In this study, the ground settlement in backside of retaining wall and the behavior of the retaining wall were analyzed according to the method of groundwater drawdown due to excavation by using two-dimensional(2D) finite element analysis. Numerical analysis was performed by applying 1) fixed groundwater level, 2) constant groundwater drawdown, and 3) transient groundwater drawdown. In addition, the behavior of the retaining wall according to the initial groundwater level, ground conditions, and surcharge pressure in backside of retaining wall was evaluated. Based on the numerical analysis results, it was confirmed that when the groundwater level is at 0.1H from the ground surface (H: Excavation soil height), the wall displacement and ground settlement are not affected by the method of groundwater drawdown, regardless of soil conditions (dense or loose) and surcharge pressure. On the other hand, when the groundwater level is at 0.5H from the ground surface, the method of groundwater drawdown was found to have a significant effect on wall displacement and ground settlement. In this case, the difference in ground settlement presents by up to 4 times depending on the method of groundwater drawdown, and the surcharge load could increase the ground settlement by up to 1.5 times.

Curtain-wall공사에 있어서 Mock-up Test 건축공사표준시방서의 개선 방안에 관한 연구 (A study on the improvement of The standard specifications for Mock-up Test in the Curtain-wall construction)

  • 이진만;강재왕;손용근;김창덕
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.491-494
    • /
    • 2003
  • 외벽을 형성하는 Curtain-wall은 비, 바람 등 자연의 기후 조건 및 주번 여건에 충분히 견딜 수 있도록 설계, 제작, 시공되어야 한다. 그러므로 전반적인 성능을 확인하기 위한 Mock-up Test는 최근에 들어서 고층 건물 및 중요도가 높은 경우 거의 일반화가 된 상황이다. 그러나 현재 Mock-uP Test의 시방서는 외국에 비해 미약하여 시방서 상으로 인한 분쟁사례가 많이 발생하고 있다. 또한 시방서 상의 표현에 있어서 불명료함으로 인하여 적용함에 있어 문제가 발생하고 있다. 따라서 현 Mock-up Test 시방서에 대한 조사를 통해 그 문제점들을 살펴보고 외국의 사례와 비교 검토하여 그 개선방안에 대한 검토를 해보고자 한다.

  • PDF

다공성 방풍벽이 설치된 삼각프리즘 주위 유동장의 수치모사 (Numerical Simulation of the Wind Flow Over a Triangular Prism with a Porous Windbreak)

  • 김현구;임희창;이정묵
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.223-233
    • /
    • 1999
  • The wind-flow characteristics over a two-dimensional triangular prism with a porous windbreak are numerically investigated. The geometry is a simplified model of large outdoor stack with a frontal wall-type windbreak which is used to prevent particle dispersion by reducing wind speed over stak surface. In the present numerical model, the RNG k-$\varepsilon$ model, the orthogonal grid system and the QUICK scheme are employed for the successful simulation of separated flow. The predicted results are compared and validated with the associated wind-tunnel experiments. In addition, the trajectories of dispersed particles and their sedimentation characteristics are quantitatively investingated using a Lagrangian turbulent-dispersion model.

  • PDF

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

CFD를 이용한 풍동 시험 모델 지지대의 공력 특성 해석 (CFD Analysis of External Balance Strut Supporting Wind Tunnel Model)

  • 김철완;박영민;이장연
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.102-105
    • /
    • 2003
  • The effect of the external balance strut on the wind tunnel model is investigated with simplified geometries. For this study, flat plate and elliptic wing are simulated with and without a cylinder. Pressure and wall shear stress distribution are analyzed to understand the effect of the cylinder.

  • PDF

풍하중이 농업시설물의 구조적 안정성에 미치는 영향 -수치해석에 의한 풍력계수분포 산정- (The Effect of Wind Force on Stability of Agricultural Structures - Numerical Calculation of Wind Pressure Coefficients -)

  • 최홍림;손정익
    • 생물환경조절학회지
    • /
    • 제3권1호
    • /
    • pp.10-19
    • /
    • 1994
  • Wind load is known to be one of major forces to influence the stability of agricultural structures. General flow fields were calculated to determine flow characteristics over the envelop of the following three types of greenhouses with arched roof : single span, twin span greenhouses, and two single span greenhouses apart 3m inbetween. Pressure coefficients along the envelop of greenhouse were numerically calculated by the k-$\varepsilon$ turbulence model, which lead to determine wind forces on it. Curvilinear coordinate for an arched roof and the upwind scheme were adopted for the study. The calculated pressure coefficients were validated with the avaliable data of Japanese Standard and NGAM Standard. The Magnitude of calculated forces over the envelop was not in good accordance with data except the windward wall. Even tile data of Japanese and NGAM Standard for validation deviated a lot from each other in quantity and quality. Such discrepancy may be attributed to different geometric and/or flow configuration conditions for experiments, or the insenstivity of the k-$\varepsilon$ turbulence model to recirculation flow.

  • PDF

층간변위 흡수형 커튼월 슬리브의 경제성 평가 (Economic Evaluation of Absorption Curtain Wall Sleeve with Relative Storey Displacement)

  • 홍상훈;유남규;서은석;김해나;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.163-164
    • /
    • 2019
  • Curtain wall is constructed in various forms and designs by forming the exterior walls of a building, and refers to non-bearing walls that divide the exterior and interior spaces of a building. Curtain walls require not only wind pressure, but also waterproof, insulation, insulation, and durability, as well as the effects of recent frequent earthquakes. Studies on the sleeve used to connect the vertical member mullions in the process of high-rise curtain walls are insufficient. In this study, sleeves connecting curtain wall mullions were developed to absorb external displacement, and the purpose of this study was to evaluate economic feasibility through comparison with existing construction methods.

  • PDF

SIDE-WALL-INLET 환기시스템 축사에서 유입구의 컨트롤을 위한 젯트모멘텀 (JET MOMENTUM CRITERIA FOR INLET CONTROL TO REDUCE WIND EFFECTS ON THE AIR DISTRIBUTION IN A SIDE-WALL-INLET VENTILATION SYSTEM)

  • 이성현
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1997년도 가을 심포지움 및 학술논문발표요지
    • /
    • pp.51-55
    • /
    • 1997
  • 국내의 축사는 윈치커튼의 위치를 조절하여 줌으로써 내부의 기류를 교환하는 개방형 축사가 대부분을 차지하고 있다. 개방형 축사의 환기는 외기풍속의 영향에의해 내부 기류의 흐름이 형성되어 바람이 없는 고온기에는 내부의 기류혼합이 잘 되지 않기 때문에 고온으로 인한 내부의 환경이 열악하다. 따라서 자연환기 축사에 배기팬 또는 입기팬을 설치하는 조합형 환기 축사가 주를 이를 것으로 판단된다. (중략)

  • PDF

GIS와 전산유체역학 모델을 이용한 기상 조건이 건물 화재에 미치는 영향 연구 (A Numerical Study on the Effects of Meteorological Conditions on Building Fires Using GIS and a CFD Model)

  • 문다솜;김민지;김재진
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.395-408
    • /
    • 2021
  • 본 연구에서는 GIS와 CFD 모델을 이용하여 풍속과 풍향이 건물 화재에 미치는 영향을 조사하였다. 이를 위해, 2020년 10월 8일 울산의 한 아파트에서 발생한 화재 사고에 대한 수치 실험을 수행하였고, 현실적인 기상 조건을 반영하기 위하여 국지기상예보시스템(LDAPS)의 바람과 온위 자료를 초기·경계 자료로 사용하였다. 먼저, 현실적인 경계 조건을 사용하여 두 가지 수치 실험을 수행하였다(규준 실험에서는 건물 화재를 고려하고, 다른 실험에서는 건물 화재를 제외하고는 규준 실험과 동일한 기상 조건 이용). 그런 다음, 규준 실험과 유입 풍속과 방향이 다른 4개의 수치 실험을 추가로 수행하였다. 수치 실험 결과, 발화 지점이 건물 풍상측에 위치할 때에는 화재로 인한 강한 상승 기류가 건물 지붕과 풍하측 지역에 영향을 미쳤다. 또한, 대피층(15층)은 건물 풍상 측 벽면의 화재를 풍하측으로 확산시키는 역할을 했다. 유입 풍속이 약할수록 발화점 주변으로의 화재가 좁게 확산되었지만 건물 위로 화염이 도달하는 고도는 상승했다. 유입 풍향이 반대인 경우, 발화 지점이 풍하측에 위치할 때에는 화염이 건물 풍상 측으로 확산되지 않았다. 본 연구 결과는 풍속과 풍향이 화재가 발생한 건물 주변의 흐름과 온도(화염) 분포에 중요하다는 것을 보여준다.

풍하중 저감형 방음판의 실증 연구 (An Empirical Study of Soundproof wall with Reduced Wind Load)

  • 최진규;이찬영
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.272-278
    • /
    • 2018
  • 최근 도시개발과 생활수준의 향상으로 인해 교통량이 크게 증가하고 있으며, 이와 더불어 증가되는 도로 소음으로 인해 많은 민원이 제기되고 있다. 이에 대한 대책으로 도로변에 높은 방음벽이 설치되고 있으나 방음벽 주요 설계 요건인 풍하중은 공사비의 기하급수적인 증가뿐만 아니라 방음벽 높이 제한의 요인으로 작용하게 된다. 이에 본 연구에서는 기존 방음벽 수준의 차음 성능과 더불어 풍하중을 획기적으로 저감할 수 있는 우수한 가격 경쟁력의 방음벽을 개발 하는 것을 목적으로 한다. 본 연구 대상의 방음판은 헬름홀츠의 공명기 이론을 바탕으로 공기와 같은 유체는 통과하고 소음은 저감할 수 있는 신개념 통기형 방음판에 해당된다. 본 연구에서는 실 크기의 금속재 방음판을 제작하여 음압투과손실실험, 풍동실험 및 재료품질 실험을 수행하여 고속도로의 품질기준을 만족하는 결과를 도출하였다. 또한 신뢰성을 검증하기 위해 현장에 제작 및 설치를 하고 시간대 별로 소음을 측정하여 방음판의 소음 차단 효과를 확인하였다. 향후 도로에 통풍형 방음벽을 설치할 경우 높은 소음 차단 효과로 인하여 쾌적한 생활환경을 조성할 수 있을 것으로 예상된다.