• 제목/요약/키워드: w-module

검색결과 1,004건 처리시간 0.033초

A CHARACTERIZATION OF w-ARTINIAN MODULES

  • Kwon, Tae In;Kim, Hwankoo;Zhou, De Chuan
    • Korean Journal of Mathematics
    • /
    • 제28권4호
    • /
    • pp.907-913
    • /
    • 2020
  • Let R be a commutative ring with identity and let M be a w-module over R. Denote by ℱM the set of all w-submodules of M such that (M/N)w is w-cofinitely generated. Then it is shown that M is w-Artinian if and only if ℱM is closed under arbitrary intersections, if and only if ℱM satisfies the descending chain condition.

옥상녹화가 PV모듈 발전량에 미치는 영향 고찰 (A study on the effect that the green roof has on the performance of PV module)

  • 유동철;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.113-119
    • /
    • 2012
  • This study aims to examine the effect of the combined application of green roof and PV system on the PV efficiency by measuring the temperature and performance of PV module in order to reduce the temperature on the roof using roof planting system and determine the potential of efficient increase in solar-light power generation. In the experimental methodology, either monocrystalline or polycrystalline PV module was installed in green roof or non-green roof, and then the surface temperature of PV was measured by TR-71U thermometer and again the performance, module body temperature, and conversion efficiency were measured by MP-160, TC selector MI-540, and PV selector MI-520, respectively. As a result, the average body temperature of monocrystalline module was lower by $6.5^{\circ}C$ in green roof than in non-green roof; that of polycrystalline module was lower by $8.8^{\circ}C$ in green roof than in non-green roof. In the difference of generation, the electricity generation of monocrystalline module in green roof was 46.13W, but that of polycrystalline module was 68.82 W, which indicated that the latter produced 22.69W more than the former.

GaAs MMIC를 이용한 X대역용 25W급 전력증폭모듈의 설계 및 구현에 대한 연구 (The Study on the design and implementation of a X-band 25W Power Amplifier Module using GaAs MMIC)

  • 김기중;김봉수
    • 한국전자통신학회논문지
    • /
    • 제9권11호
    • /
    • pp.1311-1316
    • /
    • 2014
  • 본 논문의 X-대역 25W 전력증폭기 모듈은 위성통신용 지상단말기의 송신기에 사용되는 것으로, 정지궤도 36,000Km 통신위성에 송신하기 위한 송출장비인 고출력증폭기를 구성하는 일부분이다. 지상단말에서 사용하는 고출력증폭기는 총 4개의 전력증폭기 모듈이 연계구조형으로 구성되어 고출력의 특성을 갖는다. 연계구조형에 사용된 전력증폭기 모듈 4개중에 각 모듈은 순차구조형(Serial Combining Structure)으로 구성된다. 이 전력증폭기 모듈은 Hybrid 기법을 이용하여 10개의 MMIC 전력 증폭기 칩과 Al2O3 박막 기판으로 제작한 회로를 결합하여 PAM(Power Amplifier Module)을 구성함으로써 X-대역 운용주파수에서 출력전력 25W의 전력증폭기 모듈을 구현하였다.

A HOMOLOGICAL CHARACTERIZATION OF PRÜFER v-MULTIPLICATION RINGS

  • Zhang, Xiaolei
    • 대한수학회보
    • /
    • 제59권1호
    • /
    • pp.213-226
    • /
    • 2022
  • Let R be a ring and M an R-module. Then M is said to be regular w-flat provided that the natural homomorphism I ⊗R M → R ⊗R M is a w-monomorphism for any regular ideal I. We distinguish regular w-flat modules from regular flat modules and w-flat modules by idealization constructions. Then we give some characterizations of total quotient rings and Prüfer v-multiplication rings (PvMRs for short) utilizing the homological properties of regular w-flat modules.

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

수평채널 밑면에 부착된 단일 발열모듈에서 채널높이의 변화에 따른 냉각특성 연구 (The Study about Cooling Effect of a Heated module in a Horizontal Channel with a Variation of Channel Height)

  • 이진호;유갑종;장준영;김병하
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.348-355
    • /
    • 2001
  • The coupled conduction and convection heat transfer from a protruding heated module in a horizontal channel with a variation of channel height is experimentally investigated. The input power to the module is 3, 7W and thermal resistance of module support is 0.06 , 1.03 and 158K/W. the Reynolds number ranged from 350 to 4500 corresponding to the inlet velocity(0.4~1.3 m/s) and channel height(11~35 mm). The results were obtained that the decrease of thermal resistance of module support reduces the module temperature by redistributing the heat flux and the overall thermal resistance of the module. In the study the effect of channel height is very significant in the adiabatic condition, but negligible in the conjugate condition. Finally, correlations for Nusselt number and $Q_B$/Q with a variation of Reynolds number were developed respectively.

  • PDF

휴대용 컴퓨터 내에 실장된 강제공랭 모듈 주위의 유체유동과 온도분포 (Fluid Flow and Temperature Distribution Around a Surface-Mounted Module Cooled by Forced Air Flow in a Portable Personal Computers)

  • 박상희;신대종
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.238-246
    • /
    • 2004
  • This paper reports an experimental study around a module about forced air flow by blower (35${\times}$35${\times}$6㎣) in a portable personal computer model(200${\times}$235${\times}$10㎣). Experimental report is to know three data to investigate thermal resistance, adiabatic wall temperature and visualized fluid flow around the module by combination of the moving number and the arrangement method of blower. The channel inlet flow velocity has been varied between 0.26, 0.52 and 0.78㎧, and input power ( $Q_{p}$) to the module is 4W. To investigate thermal resistance. the heated module is mounted on two boards(110${\times}$110${\times}$1.2㎣, k=20.73, 0.494W/ $m^{\circ}C$) in parallel-plate channel to forced air flow. The temperature distribution were visualized by heated module on acrylic board(k=0.262W/ $m^{\circ}C$) using liquid crystal film. Fluid flow around the module were visualized using particle image velocimetry system.

열전모듈을 이용한 자동차용 1 kW급 보조 냉난방 시스템의 성능에 관한 실험적 연구 (An Experimental Study on the Supplemental Cooling and Heating Performance Using 1 kW Thermoelectric Module for Vehicle)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.224-230
    • /
    • 2014
  • The purpose of this paper is to investigate the performance of supplemental cooling and heating system equipped with the 1 kW thermoelectric module. The system consist of 96 thermoelectric modules, heat sink with louver fin and water cooling jacket which is attached on the hot side of the thermoelectric module. The cooling and heating performance test of the thermoelectric system is conducted with various conditions, such as intake voltage, air inlet temperature, air flow volume, water inlet temperature and water flow rate at calorimeter chamber in consideration of environmental conditions in realistic vehicle drive. The experimental results of a thermoelectric system shows that the cooling capacity and COP is 1.03 kW, and 1.0, and heating capacity and COP is 1.53 kW, and 1.5 respectively.

펄스 타이밍 제어를 활용한 Ka-대역 10 W 전력증폭기 모듈 (A Ka-band 10 W Power Amplifier Module utilizing Pulse Timing Control)

  • 장석현;김경학;권태민;김동욱
    • 대한전자공학회논문지TC
    • /
    • 제46권12호
    • /
    • pp.14-21
    • /
    • 2009
  • 본 논문에서는 7개의 MMIC 전력증폭기 칩과 박막기판을 결합하여 MIC 모듈을 구성함으로써 Ka-대역 중심주파수 영역에서 10 W 이상의 출력전력을 가지는 펄스모드 전력증폭기 모듈을 설계하고 제작하였다. 전력증폭기 모듈의 제작에는 밀리미터파 대역에 적합한 수정된 형태의 윌킨슨 전력분배기/합성기와 모듈의 조림과정에서 공진을 억제하고 작은 삽입손실 특성을 보이는 CBFGCPW-Microstrip 천이구조를 활용하였다. 전력용 MMIC 바이어스 회로에 사용된 큰 값의 바이패스 캐패시터에 의해 발생되는 펄스모드 출력전력의 감소를 개선하고자 TTL 펄스 타이밍 제어 기법을 제안하였다. 제안된 방법을 10 kHz, $5\;{\mu}sec$ 펄스모드로 동작하는 전력증폭기 모듈에 적용한 결과 펄스모드 동작시간을 200 nsec 이상 개선할 수 있었고 0.62 W의 출력전력을 향상시킬 수 있었다. 구현된 전력증폭기 모듈은 59.5 dB의 전력이득과 11.89 W의 출력전력을 보여주었다.