Abstract
The purpose of this paper is to investigate the performance of supplemental cooling and heating system equipped with the 1 kW thermoelectric module. The system consist of 96 thermoelectric modules, heat sink with louver fin and water cooling jacket which is attached on the hot side of the thermoelectric module. The cooling and heating performance test of the thermoelectric system is conducted with various conditions, such as intake voltage, air inlet temperature, air flow volume, water inlet temperature and water flow rate at calorimeter chamber in consideration of environmental conditions in realistic vehicle drive. The experimental results of a thermoelectric system shows that the cooling capacity and COP is 1.03 kW, and 1.0, and heating capacity and COP is 1.53 kW, and 1.5 respectively.
Keywords
Thermoelectric module; Coolant cooling; Seebeak effect; Louver fin; Coefficient of performance;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Attey, G. S., 1998, Enhanced thermoelectric refrigeration system COP through low thermal impedance liquid heat transfer system, Proceedings of the 17th International Conference on Thermoelectrics, Nagoya, pp. 519-524.
2 Park, S. H., Lee, J. E., Kim, K. J. and Kim, D. J., 2009, A study on the performance of thermoelectric cooling system for design parameters of the cooling jacket, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 21, No. 3, pp. 149-156.   과학기술학회마을
3 Shin, J. H., Han, H. S., Kim, Y. H., Kim S. Y. and Hyun, J. M., 2010, Cooling performance of thermoelectric module with air-cooled heat exchanger fins, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 3, pp. 171-179.   과학기술학회마을
4 Lee, D. W., Jeong, H. H., An, J. C., Baek, C. H., Kim, J. H., Jeong, C. S., and Wang, Y. H., 2013, Experimental study of impact on the thermal comfort for three-dimensional air conditioning system, Proceedings of the KSAE Annual Conference, pp. 706-711.
5 Huang, B. J., Chin, C. J., and Duang, C. L., 2000, A design method of thermoelectric cooler, International Journal of Refrigeration, Vol. 23, pp. 208-218.   DOI   ScienceOn
6 Kang, B. H., Kim, S. Y., Chang, H. J., and Kim, S. Y., 2002, Cooling characteristics at hot side of the thermoelectric module for an air conditioner, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 14, No. 3, pp. 214-220.   과학기술학회마을
7 Yang, D. G., Park, K. M., Lee, K. H., Ro, Y. S., Kim, S. W., and Kim, M. S., 2011, Experimental Study on operating characteristics of anti-start air-condition and heating system using thermo electric element, Proceedings of the KSAE Autumn Annual Conference, pp. 660-665.
8 Yoo, S. Y., Hong, C. P., and Shim, W. S., 2004, A study on the performance of thermoelectric module and thermoelectric cooling system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 1, pp. 62-69.   과학기술학회마을
9 Park, M. Y. and Lee, G. S., 2007, Cooling characteristics of a liquid cooler using thermoelectric module, Proceedings of the SAREK Winter Annual Conference, pp. 1156-1161.