• Title/Summary/Keyword: volume flow rate

Search Result 1,180, Processing Time 0.041 seconds

Intrapulpal Temperature Change during Cavity Preparation on the Enamel and Dentin with an Er:YAG Laser (Er:YAG 레이저를 이용한 법랑질 및 상아질 와동 형성시의 치수내 온도변화)

  • Yang, Hee-Young;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The purpose of our study was to investigate whether the intrapulpal temperature during cavity preparation of enamel or dentin with Er:YAG laser still remained in range of safety for dental pulp protection when combined with appropriate water flow rate. The effect of different pulse repetition rates at the same pulse energy during ablation was evaluated as well. Caries-free, restoration-free extracted human molar teeth were prepared for the specimen and divided two experimental groups of enamel and dentin. Each group comprised 5 specimens and each of tooth specimens were embedded into a resin block each and measuring probe was placed on the irradiated pulpal walls. For experiments of dentin ablation, enamel layers were prepared to produce dentin specimen with a same dentin thickness of 2 mm. A pulse energy of Er:YAG laser was set to 300 mJ and three different pulse repetition rates of 20 Hz, 15 Hz and 10 Hz were employed. Laser beam was delivered with 3 seconds and less per application over enamel and dentin surfaces constant sized by $3\;mm{\times}2\;mm$ and water spray added during irradiation was a rate of 1.6 ml/min. Temperature change induced by Er:YAG laser irradiation was monitored and recorded While enamel was ablated, there was no significant difference of temperature related to pulse repetition rates(p=0.358) and temperature change at any pulse repetition rate was negligible. Significant statistical difference in temperature changes during cavity preparation in dentin existed among three different pulse groups(p=0.001). While temperature rise was noticeable when the dentinal wall was perforated, actual change of temperature due to Er:YAG laser irradiation was not enough to compromise safety of dental pulp when irradiation was conjugated with appropriate water spray. Conclusively, it can be said that cavity preparation on enamel or dentin with an Er:YAG laser is performed safely without pulp damage if appropriate volume of water is sprayed properly over the irradiated site.

Effects of Head-Down Tilt$(-6^{\circ})$ on Hemodynamics and Plasma Catecholamine Levels (도립$(-6^{\circ})$이 혈장 Catecholamine 및 심장혈관계에 미치는 영향)

  • Song, Dae-Kyu;Bae, Jae-Hoon;Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.211-223
    • /
    • 1987
  • Head-down tilt (HDT) at $-6^{\circ}$ has been commonly used as the experimental model in both man and animals to induce the blood shift toward the head or central protion of the body, demonstrating similar physiological effect encountered in the weightlessness in the orbital flight. There are few reports about the physiological response upon the cardiovascular regulatory system or the tolerance to the $(-6^{\circ})$ HDT within a relatively short period less than 1 hour. Therefore, the purpose of this study way to observe the effects of $-6^{\circ}$ HDT on cardiovascular system within 30 minutes and to evaluate early regulatory mechanism for simulated hypogravity. Ten mongrel dogs weighing 8-12 kg were anesthetized with the infusion of 1% ${\alpha}-chloralose$ (100 mg/kg) intravenously, and the postural changes were performed from the supine to the $-6^{\circ}$ head-down Position, then from the head-down to the supine (SUP), and each posture was maintained for 30 minutes. Blood flow $({\dot{Q}})$ through common carotid and femoral arteries were determined by the electromagnetic flowmeter. Mean arterial pressure (MAP), heart rate (HR), respiratory rate , and pH, $P_{O_2}$, $P_{CO_2}$ and hematocrit (Hct) of arterial and venous blood were also measured. The peripheral vascular resistance was calculated by dividing respective MAP values by ${\dot{Q}}$ through both sides of common carotid or femoral arteries. The concentration of plasma epinephrine and norepinephrine was determined by Peuler & Johnson's radioenzymatic method. The results are summarized as follows: In the initial 5 minutes in $-6^{\circ}$ HDT, HR was significantly (p<0.05) increased and MAP slightly decreased. Although ${\dot{Q}}$ and carotid peripheral artery resistance were not significantly changed, ${\dot{Q}}$ through femoral artery was diminished and femoral peripheral artery resistance was elevated. In the SUP, the initial changes of MAP and HR were increased (p<0.05), but those of ${\dot{Q}}$ and peripheral vascular resistance through both common carotid and femoral arteries were not significant. After 10 minutes of each postural change in both HDT and SUP, MAP was maintained almost equal to that of the level of pretilting control. During 60 minutes of both postural changes of HDT and SUP, $P_{O_2}$ and Hct were not changed significantly. However pH tended to increase slowly and $P_{CO_2}$ was gradually decreased. The pH and $P_{CO_2}$ seemed to be related to the increased respiratory rate. Plasma epinephrine concentration was not changed significantly and plasma norepinephrine concentration was slightly decreased in the course of HDT and also at 10 minutes of SUP. However these concentration changes were statistically insignificant. From these results, it may be concluded that the effect of $-6^{\circ}$ HDT for 30 minutes on the cardiovascular system and plasma catecholamine levels of the dog is minimum and it is suggestive that the cardiovascular regulatory mechanism, possibly mediated by so called gravity receptors including baroreceptor and volume receptor, has been properly and adequately operated.

  • PDF

Effect of Additional 1 hour T-piece Trial on Weaning Outcome to the Patients at Minimum Pressure Support (최소압력보조 수준에서 추가적 1시간 T-piece 시도가 이탈에 미치는 영향)

  • Hong, Sang-Bum;Koh, Youn-Suck;Lim, Chae-Man;Ann, Jong-Jun;Park, Wann;Shim, Tae-Son;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.813-822
    • /
    • 1998
  • Background: Extubation is recommended to be performed at minimum pressure support (PSmin) during the pressure support ventilation (PSV). In field, physicians sometimes perform additional 1 hr T-piece trial to the patient at PSmin to reduce re-intubation risk. Although it provides confirmation of patient's breathing reserve, weaning could be delayed due to increased airway resistance by endotracheal tube. Methods: To investigate the effect of additional 1 hr T-piece trial on weaning outcome, a prospective study was done in consecutive 44 patients who had received mechanical ventilation more than 3 days. Respiratory mechanics, hemodymic, and gas exchange measurements were done and the level of PSmin was calculated using the equation (PSmin=peak inspiratory flow rate $\times$ total ventilatory system resistance) at the 15cm $H_2O$ of pressure support. At PSmin, the patients were randomized into intervention (additional 1 hr T-piece trial) and control (extubation at PSmin). The measurements were repeated at PSmm, during weaning process (in cases of intervention), and after extubation. The weaning success was defined as spontaneous breathing more than 48hr after extubation. In intervention group, failure to continue weaning process was also considered as weaning failure. Results: Thirty-six patients with 42 times weaning trial were satisfied to the protocol. Mean PSmin level was 7.6 (${\pm}1.9$)cm $H_2O$. There were no differences in total ventilation times (TVT), APACHE III score, nutritional indices, and respiratory mechanics at PSmin between 2 groups. The weaning success rate and re-intubation rate were not different between intervention group (55% and 18% in each) and control group (70% and 20% in each) at first weaning trial. Work of breathing, pressure time product, and tidal volume were aggravated during 1 hr T-piece trial compared to those of PSmin in intervention group ($10.4{\pm}1.25$ and $1.66{\pm}1.08$ J/L in work of breathing) ($191{\pm}232$ and $287{\pm}217$cm $H_2O$ s/m in pressure time product) ($0.33{\pm}0.09$ and $0.29{\pm}0.09$ L in tidal volume) (P<0.05 in each). As in whole, TVT, and tidal volume at PSmin were significantly different between the patients with weaning success ($246{\pm}195$ hr, $0.43{\pm}0.11$ L) and the those with weaning failure ($407{\pm}248$ hr, $0.35{\pm}0.10$L) (P<0.05 in each). Conclusion : There were no advantage to weaning outcome by addition of 1 hr T-piece trial compared to prompt extubation to the patient at PS min.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

THE ANTICANCER EFFECT OF PACLITAXEL($Taxol^{(R)}$) IN ORAL SQUAMOUS CELL CARCINOMA XENOGRAFT (이종 이식된 구강편평세포 암종에서 Paclitaxel ($Taxol^{(R)}$)의 항암 효과)

  • Kim, Ki-Hwan;Kim, Chul-Hwan;Han, Se-Jin;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.95-110
    • /
    • 2006
  • The treatment for oral and maxillofacial carcinoma with chemotherapeutic agents is evaluated by many effective methods to reduce the tumor mass and cancer cell proliferation. However these chemotherapy have many serious side effects, such as bone marrow suppression, renal toxicity, G-I troubles. Therefore a possible approach to develop a clinically applicable chemotherapeutic agent is to screen anticancer activity of Taxol which is known to have very little side effect and have been used to breast cancer and ovarian carcinoma. Taxol is a new anti-microtubular anti-cancer agent extracted from the bark of the Pacific yew, Taxus brevifolia. Paclitaxel(Taxol) acts by promoting tubulin polymerization and over stabilizing microtubules agianst depolymerization. Despite the constant improvements of methods of the cancer treatment especially chemotherapy, the rate of cancer metastasis and recurrent are not decreased. Thus the investigation of new drug which have very little side effect and a possible clinically application continues to be a high priority. Considering that the Taxol have shown very effective chemotherapeutic agent with relatively low toxicity in many solid tumors, it deserves to evaluate its efficacy in oral squamous cell carcinoma. In this study, to investigate the in-vivo and in-vitro anti-cancer efficacy of Taxol in oral squamous cell carcinoma and lastly, the potency of Paclitaxel in the clinical application for oral cancer was evaluated. In vivo study, after HN22 cell line were xenografted in nude mice, the growth of tumor mass was observed, 3 mg/Kg taxol was injected intraperitoneally into nude mice containing tumor mass. The methods of these study were measurement of total volume of tumor mass, histopathologic study, immunohistochemical study, drug resistance assay, growth curve, MTT assay, flow cytometry, cDNA microarray in vivo and in vitro. The results were obtained as following. 1. The visual inspection of the experimental group showed that the volume of the tumor mass was slightly decreased but no significant difference with control group. 2. Ki-67 index was decreased at weeks 4 in experimental group. 3. Microscopic view of the xenografted tumor mass showed well differentiated squamous cell carcinoma and after Taxol injection, some necrotic tissue was seen weeks 4. 4. The growth curve of the tumor cells were decreased after 1day Taxol treatment. 5. According to the MTT assay, HN22 cell line showed relative drug resistancy above $5\;{\mu}g/ml$ concentrations of Taxol. 6. In drug resistance assay, the decrease of cell counts was seen relatively according to concentration. 7. In Flow cytometry, G2M phase cell arrests were seen in low concentration of the Taxol, while S phase cell arrests were seen in high concentration of the Taxol. 8. Using cDNA microarray technique, variable gene expression of ANGPTL4, TXNRD1, FAS, RRAGA, CTGF, CYCLINEA, P19, DUSP5, CEBPG, BTG1 were detacted in the oral squamous cell carcinoma cell after taxol treatment. In this study paclitaxel is effective against oral squamous cell carcinoma cell lines in vitro, but week effect was observed in vivo. So we need continuous study about anticancer effect of taxol in vivo in oral squamous cell carcinoma.

Effect of Application Rate of a Controlled Release Fertilizer on the Changes in Medium EC and Growth of Subirrigated Vinca and Salvia (저면관수 재배에서 완효성 비료의 양이 배지의 EC 및 일일초와 살비아의 생장에 미치는 영향)

  • Kang, Jong Goo;Lee, In Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • Plug seedlings of vinca (Catharanthus roseus L. 'Pacifica Punch') and salvia (Salvia splendens F. Sellow ex Roem & Schult 'Maestro') were transplanted into square plastic pots (145 mL volume) filled with a soilless growing medium. To determine the effect of application rate on the growing medium EC and growth of plants, 0, 0.5, 1.0, 1.5, 2.0 and 4.0 g per pot of a controlled release fertilizer (14-14-14 Osmocote, 14N-6.2P-11.6K) were mixed with the growing medium. Plants were subirrigated daily with tap water. In both vinca and salvia, growing medium EC increased as application rate was elevated. Growing medium EC was relatively constant over a whole crop period when the application rate was less than 1.5 g per pot, while it decreased throughout the experiment at higher application rates such as 2.0 to 4.0g per pot in both species. The greatest leaf area, plant height, and shoot dry weight of vinca were obtained when plants were fertilized with 2.0 to 4.0 g per pot of the fertilizer, resulting in a growing medium EC of $1.0{\sim}1.7dS{\cdot}m^{-1}$ throughout the experiment. Leaf area, shoot dry weight, and chlorophyll content of salvia increased with elevated application rates. Leaf area, shoot dry weight, and chlorophyll content of salvia were the greatest when plants were fertilized with 4.0 g per pot, resulting in growing medium EC of $1.0{\sim}4.0dS{\cdot}m^{-1}$ throughout the experiment. Plant height of salvia was the greatest when plants were fertilized with 2.0 to 4.0g per pot. Concentrations of nitrogen (N), phosphorus (P), potassium (K), magnesium (Mg), and sulfur (S) in the shoots of vinca increased, while concentration of calcium (Ca) decreased with elevated application rates. Concentrations of boron (B) and manganese (Mn) in the shoots of vinca increased as the application rate decreased.

Phosphorous Removal in a Free Water Surface Wetland Constructed on the Gwangju Stream Floodplain (광주천 고수부지에 조성한 자유수면인공습지의 인 제거)

  • Yang, Hong-Mo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.100-109
    • /
    • 2012
  • Removal rates of $PO_4-P$ and TP in a free water surface wetland system were investigated. The system was established in 2008 on a floodplain in the middle reach of the Gwangju Stream flowing through Gwangju City. Its dimensions were 46 meters in length and 5 meters in width. Two year old Typha angustifloria L. growing in pots were planted on half of the area and Zizania latifolia Turcz on the other half in 2008. Stream water was funneled into the wetlands by gravity flow, and its effluent was discharged back into the stream. The influent volume was controlled by valves and water depth was adjusted by wires. Volume and water quality of inflow and outflow were analyzed from January to December in 2010. Inflow into the system averaged approximately $710m^3/day$ and hydraulic residence time was about 1.5 hours. Average influent and effluent $PO_4-P$ concentration were 0.144 and 0.103mg/L, respectively, and $PO_4-P$ abatement amounted to 28.6%. Influent and effluent TP concentration averaged 0.333 and 0.262mg/L, respectively, and TP retention reached to 20.7%.$PO_4-P$ removal rate(%) during plant growing season(31.448) was significantly high(p<0.001) when compared with that during plant non-growing season(25.829). TP abatement rate(%) during plant growing season(27.230) was also significantly high(p<0.001) when compared with that of the non-growing season(14.856). Major phosphorous removals in the system resulted from adsorption of phosphorous in the litter-soil layers; sedimentation of particulate phosphorous and Ca, Al, Fe bounded phosphates; and absorption of phosphorous by emergent plants. The adsorption and sedimentation occurred throughout the year, however, the absorption took place during plant growing season. This resulted in higher removals of $PO_4-P$ and TP during plant growing season.

Evaluation of Growth Inhibition for Microcystis aeruginosa with Ultrasonic Irradiation Time (초음파 조사시간에 따른 Microcystis aeruginosa의 성장억제 평가)

  • Kang, Eun Byeol;Joo, Jin Chul;Jang, So Ye;Go, Hyeon Woo;Park, Jung Su;Jeong, Moo Il;Lee, Dong Ho
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.3
    • /
    • pp.183-193
    • /
    • 2022
  • The growth inhibitory effect of Microcystis aeruginosa according to the ultrasonic irradiation time was evaluated using a large algae sample volume (10 L) for various ultrasonic irradiation times (0.5, 1, 1.5, 2, 2.5 and 3 hr) at a laboratory scale. Based on the analysis of Chl-a and cell number of M. aerginosa, algae growth inhibition was observed with the decrease in Chl-a and cell number in all experimental groups after the ultrasonic irradiation. For the experimental group (T_B, T_C, T_D) with an ultrasonic irradiation time of less than 2 hours, rapid regrowth of algae was observed after growth inhibition, but the experimental group (T_E, T_F, T_G) with an irradiation time of more than 2 hours successfully inhibited algal growth lasting one or two more days. Based on the comparison of the recovery time to initial cell number the experimental group (T_B, T_C, T_D) took less than 20 days whereas the experimental group (T_E, T_F, T_G) took about 30 days. Correspondingly, the experimental group showed a high first order decay rate (𝜅) in proportion to the ultrasonic irradiation time during the growth inhibition period. Additionally, the specific growth rates (𝜇) during regrowth in the experimental group with irradiation time of more than 2 hours were relatively low compared to those in the experimental group with less than 2 hours. Therefore, ultrasonic irradiation for more than 2 hours is required for long-term (30 days) inhibition of algal growth in stagnant waters. However, the appropriate ultrasonic irradiation time for algae growth inhibition should be determined according to various field conditions such as the volume of stagnant water, water depth, flow rate, algae concentration, etc. Finally, damages to the algal cell surface and cell membrane were clearly observed, and both destruction and disturbance of gas vesicles of M. aeruginosa in the experimental group were discovered, indicating the growth inhibitory effect of Microcystis aeruginosa according to the ultrasonic irradiation time was confirmed.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Characteristics and Control of Microthrix Parvicella Bulking in Biological Nutrient Removal Plant (생물학적 영양소제거공정에서 Microthrix Parvicella에 의한 Bulking 특성 및 제어)

  • Lee, H.;Ahn, K.
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1101-1106
    • /
    • 2006
  • Many BNR (Biological Nutrient Removal) plants have experienced a bulking problem, mainly due to the growth of filamentous organisms, particularly during the winter months. This study investigated the problem of bulking due to the growth of M. parvicella both at a full-scale municipal wastewater treatment plant and a pilot scale plant located in the C city. The full-scale facility was operated at a flow rate of $51,000m^3/d$, an F/M (Food-to-Microorganism) ratio of 0.12 kgBOD/kgMLVSS/d and an SRT (Solids Retention Time) higher than 25 days, respectively. This plant experienced bulking and foaming problems at low temperatures below $15^{\circ}C$ since it was retrofitted with the BNR system in 2003. The pilot plant employed had an identical process configuration as the full scale one and used the same wastewater source. It was operated at a flow rate of $3.8m^3/d$, temperatures between 10 to $25^{\circ}C$ and SRTs between 10 and 25 days. At full scale, the M. parvicella growth and SVI (Sludge Volume Index) patterns were studied in conjunction with temperature variations. At pilot scale, DO and SRT variations were also explored, in addition to the filamentous bacteria growth and SVI patterns. During the full-scale investigation, over a 3 year period, it was noted that the SVI was maintained within acceptable operational values (i.e. under 160) during the summer months. Moreover settling in the secondary clarifiers was good and was not affected by the presence of M. parvicella. In contrast, at low mean temperatures during winter, the SVI increased to over 300. Overall, as the temperature decreased, the predominance of M. parvicella became apparent. According to this study, M. parvicella growth could be controlled and SVI could drop under 160 by a change in operational conditions which involved an increase in DO concentration between 2 and 4 mg/L and a decrease in SRT to less than 20 days.