• 제목/요약/키워드: voltage flicker

검색결과 100건 처리시간 0.03초

풍력발전시스템의 배전계통 연계운전 시 전의품질 해석 (Power Quality Analysis of Wind Power System Embedded in Distribution Networks)

  • 김응상;노병권;추진부;장병태;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.229-231
    • /
    • 1999
  • This paper deals with electromagnetic transient modelling of wind power system embedded in distribution networks. Wind power system consists of induction generator link reactor, distribution line, and controlled load unit. The introduction of embedded wind power system presents a new set of conditions to networks both with respect to power quantify needed to be transported and power quality such as sag swell, very short interruption, and flicker. This paper investigates the transient behavior of voltage, frequency, and load flow in wind driven induction generation system embedded in distribution networks.

  • PDF

과도현상 해석을 위한 EAFs 부하 무델의 개발 (An Electric Arc Furnaces Load Model for Transient Analysis)

  • 장길수;;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정 (Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method)

  • 전용제;김향율;김재형;한은주;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1 V

  • PDF

전기품질 진단기술의 방향 (The Direction of Power Quality Analysis Technology)

  • 강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.16-18
    • /
    • 2005
  • Becoming more and more diversified and complicated, power quality management has focused on the electricity-failure duration(including the numbers), the appropriate rate of voltage(average voltage during 30 minutes), the stability rate of frequency etc. as a basic goal value. And recently the focus is moving into the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, instantaneous electricity failure, flicker etc. by the development of electricity & electronics and communication equipments, which had not been so big problems before. This paper will address the flow of analysis technology and forecast the desirable direction of power quality analysis technology in the future.

  • PDF

Power Quality Improvement of an Electric Arc Furnace Using a New Universal Compensating System

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein;Ali Yazdian-Varjani
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.195-204
    • /
    • 2006
  • This paper presents a new compensating system, consisting of series and shunt active filters, for mitigating voltage and current disturbances. The shunt filter is used to compensate for unbalanced and distorted load currents. The series filter comprises two inverters, used to suppress voltage disturbances and handle source currents independently. This configuration is devised to reduce the overall cost of active compensators by using low-frequency high-current switches for the latter inverter. The filters are controlled separately using a novel control strategy. Since voltages at the point of common coupling contain interharmonics, conventional methods cannot be used for extracting voltage references. Therefore, voltage references are obtained from generated sinusoidal waveforms by a phase-locked loop. Current references are detected based on rotating frame vector mapping. Simulation results are presented to verify the system.

웨이블릿 변환의 검출 특성을 이용한 전압강하 검출에 관한 연구 (A Study for Voltage Sag Detection Using Detection Characteristic Of Wavelet Transform)

  • 정승복;김재철;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.172-174
    • /
    • 2005
  • Recently, a concern of power qualify increases because of electronic device development and well-being generation. Power quality problems such as voltage sag, harmonics, flicker etc. have adverse effects on electric devices. Therefore, power quality problems have been monitored. This paper studies a detection of voltage sag that is more severer than the others. A voltage sag has been monitored using rms or wavelet method. This paper proposes an advance detection method using wavelet. An error Of Start Point differs error of ending point. We use this difference. So, we respectively revise detection error. Also, we revise multiplying average error rate.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

전압 플리커 및 고조파 보상을 위한 배전용 STATCON의 제어알고리즘 개발 (Development of Control Algorithm of D-STATCON(Distribution STATic-CONden: Compensations of Voltage Flicker and Harmonics)

  • 전영수;오관일;이기선;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1282-1286
    • /
    • 1999
  • This paper presents the DQ transfomation and space vector modulation method to develop a control algorithm of distribution STATCON(STATic CONdenser) for line voltage regulation, dc link voltage regulation and harmonics compensation. The Performance analysis of a PI with ramp comparision and synchronous reference frame current controller is carried out. Based on these analysis, the control performances are desirable to compensate the harmonics and to regulate de link and line voltage of Distribution line.

  • PDF

공간연면 직렬간극의 섬락방전특성에 관한 연구 (A study on the flash over characteristics in space and surface series air gaps)

  • 김원섭
    • 전기의세계
    • /
    • 제25권1호
    • /
    • pp.87-94
    • /
    • 1976
  • The characteristic of flashover electric discharge has been brought to light in this paper for the situation in which the space and creeping gaps are laid out in series. The result of this study has disclosed the facts that the over all flashover characteristics have three kind of features such as unilateral increase after increase, and increase after decrease in compliance with varied layout method and relative magnitude of gap length, and accordingly there exist a ratio among the magnitudes of gap length and a proper layort method through which the over all flashover voltage reaches the highest. Also involved with this study is the theoretic analysis of flashover characteristics even in the case of creeping electric discharge from hand tip of the gauge, where the over all value of flashover voltage can be estimated from the peculiar value of flashover voltage and flicker voltage for the space and creeping gap within the extent of 5% error.

  • PDF

STATCON 제어방식에 따른 특성 연구 (A Study on the Characteristics of Control Schemes for STATCON)

  • 한영성;차재덕;홍순욱;이학성;문건우;윤석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2076-2078
    • /
    • 1998
  • This paper presents STATCON(Static Condenser) control schemes for voltage regulation, power factor correction and harmonics mitigation. Each control scheme can be applied in the system depending on the system requirements. The 20KVA STATCON is developed and tested in the reduced system model for the verification of three different control algorithms. The results of proposed controls are compared for power factor correction and voltage regulation algorithms. For each algorithm, harmonic mitigation scheme is adopted as a part of control. Finally verification of STATCON for the transient response is implemented by voltage flicker test.

  • PDF