• Title/Summary/Keyword: visualization technique

Search Result 890, Processing Time 0.034 seconds

X-ray Micro-imaging of Arsenic Absorption of Sap Flow in Xylem Vessels of Pteris (X-ray 영상기법을 이용한 비소 흡수가 고사리 내부 수액 거동에 미치는 영향 연구)

  • Lee, Jin-Pyoung;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.30-36
    • /
    • 2007
  • The global environment is deteriorating at an alarming rate, despite of enhanced international environmental regulation. Many studies have been performed to reduce toxic pollutants. Recently, plant-based phytoremediation technology for moving toxic contaminants from soil and water has been receiving large attention. Arsenic-contaminated soil is one of the major pollutant sources for drinking water. Pteris erotica has been known as a hyper-accumulator of arsenic from soils. In this study, we investigated the effect of arsenic absorption on sap flow inside xylem vessels of Pteris. The synchrotron X-ray micro-imaging technique was employed to monitor the refilling process of water containing arsenic inside the xylem vessels of Pteris's leaves and stems non-invasively. The captured phase-contrast X-ray images show both anatomy of internal structure and transport of water inside Pteris. The exposure of Pteris to arsenic solution was found to increase largely the water raise speed in xylem vessels. The present results would provide important information needed for understanding the mechanisms of accumulation and transportation of toxic materials in plants.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

Active Infrared Thermography for Visualizing Subsurface Micro Voids in an Epoxy Molding Compound

  • Yang, Jinyeol;Hwang, Soonkyu;Choi, Jaemook;Sohn, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.106-114
    • /
    • 2017
  • This paper presents an automated subsurface micro void detection technique based on pulsed infrared thermography for inspecting epoxy molding compounds (EMC) used in electronic device packaging. Subsurface micro voids are first detected and visualized by extracting a lock-in amplitude image from raw thermal images. Binary imaging follows to achieve better visualization of subsurface micro voids. A median filter is then applied for removing sparse noise components. The performance of the proposed technique is tested using 36 EMC samples, which have subsurface (below $150{\mu}m{\sim}300{\mu}m$ from the inspection surface) micro voids ($150{\mu}m{\sim}300{\mu}m$ in diameter). The experimental results show that the subsurface micro voids can be successfully detected without causing any damage to the EMC samples, making it suitable for automated online inspection.

Visualization of Gene Transfer into Live Cells Using Fluorescent Semiconductor Nanocrystals

  • Kim Jung Kyung;Lim Sun Hee;Lee Yongku;Shin Young Shik;Chung Chanil;Chang Jun Keun;Yoo Jung Yul
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.81-82
    • /
    • 2003
  • We have developed the method for the conjugation of biotinylated DNA to streptavidin-coated QDs. QD-DNA conjugates and a high-sensitive fluorescence imaging technique are adopted to visualize gene transport across the membrane of the live cell in real time. Endocytotic cellular uptake of oligonucleotide and electrically-mediated plasmid DNA transfer into the live cell are monitored by a quantitative microscopic imaging system. Long-term kinetic study enables us to reveal the unknown mechanisms and rate-limiting steps of extracellular and intracellular transport of biomolecules. We designed experimental protocols to conjugate the oligonucleotide or the plasmid DNA to commercially available streptavidin-coated QDs. Gel electrophoresis is used to verify the effect of incubation time and the molar ratio of QDs and DNA on the conjugation efficiency. It is possible to fractionate the QD-DNA conjugates according to the DNA concentration and obtain the purified conjugates by a gel extraction technique.

  • PDF

Development of Image-based Fluorescence Photobleaching Technique for Measuring Macromolecule Diffusion in Biological Porous Medium (생체 다공성 매질에서 분자 확산 측정을 위한 영상 기반 형광 광표백 기법 개발)

  • Lee, Dong-Hee;Lee, Jeong-Hoon;Park, Choon-Ho;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • Fluorescence recovery after photobleaching (FRAP) has been widely used for the measurement of molecular diffusion in living cells and tissues. We developed an image-based FRAP (iFRAP) technique using a modified real-time microscope and a 488 nm Ar-ion laser. A fractional intensity curve was obtained from the time-lapse images of fluorescence recovery in the bleached spot to determine the diffusion coefficient of fluorescently labeled macromolecules in porous medium. We validated iFRAP through experiments with agar gels (0.5% and 1.5% w/v) containing FITC-Dextrans (10, 70 and 500 kDa MW). Further validation was performed by a Monte Carlo approach, where we simulated the three-dimensional random walk of macromolecules in agar gel model. Diffusion coefficients were deduced from the mean square displacement curves and showed good agreements with those measured by iFRAP.

Study on Measurement of Flow Distribution for Design of Room Air Conditioner with High-Efficiency (고효율 룸 에어컨 설계를 위한 유동 분포 측정에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.853-856
    • /
    • 2009
  • Test models which have geometrical similarities with a real room air conditioner (RAC) have been manufactured including visualization windows so that a laser beam can pass through a cross flow fan. Then, flow distributions of the RAC have been investigated using a visualization technique such as a Particle Image Velocimetry (PIV) to analyze an efficiency and noise of the RAC. Pitot tubes have also been used to measure the flow velocity inside the RAC with various positions to confirm the measurement accuracy of the PIV technique. The measured flow velocities have been analyzed and new designs of the RAC have been proposed to improve the efficiency and to reduce the noise for the RAC in this study.

  • PDF

The Development of Technique for the Visualization of Geological Information Using Geostatistics (지구통계학을 활용한 지반정보 가시화 기법 개발)

  • 송명규;김진하;황제돈;김승렬
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.501-508
    • /
    • 2001
  • A graph or topographic map can often convey larger amounts of information in a shorter time than ordinary text-based methods. To visualize information precisely it is necessary to collect all the geological information at design stage, but actually it is almost impossible to bore or explore the entire area to gather the required data. So, tunnel engineers have to rely on the judgement of expert from the limited number of the results of exploration and experiment. In this study, several programs are developed to handle the results of geological investigation with various data processing techniques. The results of the typical case study are also presented. For the electric survey, eleven points are chosen at the valley to measure the resistivity using Schlumberger array. The measured data are interpolated in 3-dimensional space by kriging and the distribution of resistivity are visualized to find weak or fractured zone. The correlation length appears to be around 5 to 20 meter in depth. Regression analyses were performed to find a correlation length. No nugget effect is assumed, and the topographic map, geologic formation, fault zone, joint geometry and the distribution of resistivity are successfully visualized by using the proposed technique.

  • PDF

Interest-Information Monitoring System for Debugging of Parallel Programs (병렬 프로그램의 디버깅을 위한 관심정보 모니터링 시스템)

  • Park, Myeong-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.607-610
    • /
    • 2007
  • In this paper, proposes the monitoring system it will be able to trace the executed of each threads in OpenMP based a parallel program. The monitoring system of existing in uses each threads label information and the analysis technique which uses the access-history was most. This has the problem which raises the time and space complexity which is caused by with massive information creation. In this paper, only the thread which includes interest information it creates tracking information with the target. And it provides information which is intuitive to the user it provides the visualization system for to a same time. The visualization model is composed the images-information of a base. This does to be it will be able to understandable a program execute situation using an image processing technique. Therefore, this paper provides the parallel program an effective debugging environment.

  • PDF

Application of Magnetic Resonance Thermometry (MRT) on Fully Developed Turbulent Pipe Flow using 3T and 7T MRI (완전발달 난류 원관 유동에서의 3T 및 7T MRI를 이용한 자기공명온도계의 적용)

  • You, Hyung Woo;Baek, Seungchan;Kim, Dong-Hyun;Lee, Whal;Oh, Sukhoon;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.1
    • /
    • pp.26-37
    • /
    • 2020
  • Magnetic resonance thermometry (MRT) is a technique capable of measuring three-dimensional mean temperature fields by utilizing temperature-dependent shifts in proton resonance frequency. In this study, experimental verification of the technique is obtained by measuring 3D temperature fields within fully developed turbulent pipe flow, using 3T and 7T MRI scanners. The effect of the proton resonance frequency (PRF) thermal constant is examined in detail.

u-GIS National Land Information Providing System (u-GIS 국토정보 제공 시스템)

  • Kim, Jae-Chul;Lee, Kyu-Chul
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The u-GIS national land information providing technology is the technology which maximizes the application of u- GIS data through the national land information platform technique of the next generation web and provides a user with the on-demand national land information in the ubiquitous environment. Recently, as the environment emphasizing the web as a platform 'Web 2.0' emerges, the where 2.0 which is paradigm is diffused in the spatial information area. And the Geo-spatial Web technology develops in a center. Moreover, it is changed to the open platform of the user participation trend. And the consumer of the geo-spatial information is changed to the end-user center from the public institution. The geo-spatial technique is technologically faced with the new challenge. In this paper, we analyze the technical tendency about a paradigm, And we present the u-GIS national land information platform technique, the u-GIS national land information visualization technology, the u-GIS national land information GeoDRM integrative technique, and the u-GIS national land information mobile application technology as the essential elemental technology for overcoming this.

  • PDF