• Title/Summary/Keyword: visual measurement

Search Result 930, Processing Time 0.028 seconds

Using DGE for Enhancing SMK and PCK of Pre-service Elementary Teachers for the Figure Problem (예비 초등교사들의 도형 문제에 대한 SMK와 PCK 강화를 위한 DGE 활용)

  • Kang, Jeong Gi;Kim, Min Jeong;Jeong, Sang Tae;Roh, Eun Hwan
    • Journal of the Korean School Mathematics Society
    • /
    • v.17 no.2
    • /
    • pp.139-166
    • /
    • 2014
  • The purpose of the study is to enhance the teaching competence for pre-service elementary teacher by using DGE in order to enhance SMK and PCK for them. To do this, we investigated the initial SMK and PCK for 23 pre-service elementary teachers, the reality of implementation activity of DGE and the change of SMK and PCK after quest activity by DGE. As results, 3 pre-service elementary teachers made errors which are misunderstanding a general angle as special angle, an excessive jump of logic and a circulation logic in the aspect of an initial SMK. In the aspect of contents of PCK, most of pre-service elementary teachers proposed teaching focused on the character using in the problem solving. And most of pre-service elementary teachers proposed teaching methods which are based on explanation, measurement and material manipulation. The reality of implementation activity of DGE was classified 4 cases which are a difficulty in understanding the concept of dynamics and embodying in DGE, an obsession about construction of $75^{\circ}$ and generalization, a difficulty in interpreting 'folding activity' mathematically and a good implementation activity. After quest activity by DGE, the case which is misunderstanding a general angle as special angle could be improved, but the others are not. And after quest activity by DGE, most of pre-service elementary teachers still proposed teaching focused on the character using in the problem solving in the aspect of contents of PCK, and some of pre-service elementary teachers added only teaching methods which are involving visual confirmation by GSP. From these results, we could extract some pedagogical implications helping pre-service teachers to reinforce SMK and PCK by DGE.

  • PDF

The Correlation between Acupuncture Therapy on Knee Osteoarthritis and BMI (퇴행성 슬관절염의 침치료 호전도와 BMI와의 상관성)

  • Yeo, In Ho;Kim, Jung Hyun;Jung, Se Ho;Jo, Na Young;Roh, Jeong Du;Kim, Kap Sung;Lee, Seung Deok;Kim, Eun Jung;Lee, Cham Kyul;Lee, Eun Yong
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.101-107
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the correlation between acupuncture therapy on knee osteoarthritis and BMI. Methods : Data on assessment measurements of knee osteoarthritis and obesity were obtained from 31 patients suffering from knee osteoarthritis from May, 2011 to September, 2012. The assesment measurements consisted of body mass index(BMI), visual analogue scale(VAS) and Western Ontario and McMaster Universities(WOMAC) index. Statistical correlations among assessment measurements were evaluated by examining the Pearson's correlation coefficients. Results : 1. The average age of all patients was $58.87{\pm}9.48$(male : $63.67{\pm}11.34$, female : $57.72{\pm}8.86$). 2. The average BMI of all patients was $25.41{\pm}3.06kg/m^2$. According to clinical definition of obesity by Korean Society for the Study of Obesity, 25.81% of all patients was within normal weight, 25.81% was overweight, 38.71% was obesity and 9.67% was morbid obesity. 3. There were no significant correlations in statistics among assessment measurements. Conclusions : There is significant correlation between knee osteoarthritis and obesity according to many clinical and experimental researches. So more studies on correlation between knee osteoarthritis and obesity and development of assessment measurement are needed.

Experimental Observation of Instability of Supersonic Submerged Jets (수중초음속제트의 불안정성에 대한 실험적 고찰)

  • 정재권;이대훈;차홍석;박승오;권세진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • An experimental investigation on the structure and dynamic behavior of two dimensional over-expanded air jets exiting into water was carried out. The hish speed digital video imaging and static pressure distribution measurement were made to characterize the structure and time-dependant behavior of the jets. Mach number at the jet exit was 2.0 and was slightly less than the value predicted by the ideal nozzle calculation. Variance of jet spreading angle at different stagnation condition was measured as a function of mass flow rate. Periodic nature of the air jet distortion in water was observed and the frequency of the repetition was approximately 5-6 Hz for all cases tested. Three characteristic length scales were defined to characterize jet structure. $L_1$, maximum width of the plume when the periodic instability occurs, $L_2$, width of the jet where secondary reverse flow entrained jet flow and $L_3$, distance from the jet exit to the location where entrainment of the secondary reverse flow occurs. The ratio of $L_1$ and $L_2$ decreased with increasing stagnation pressure, i.e. mass flow rate. $L_3$ increased with increasing stagnation pressure. The temporal behavior of static pressure measurements also showed peak around frequency of 5, which corresponds the frequency obtained by visual measurements

Fusion Analytical Sensitivity of Rapid Influenza Antigen Limit of Detection Tests for Human Influenza virus (인플루엔자 바이러스에 대한 신속 항원 검출 검사 검출한계의 융합적 분석)

  • Song, Chang-Sub;Sung, Hyun-Ho;Kim, Jung-Hyun;Kim, Dae-Eun;Park, Chang-Eun;Yoon, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.165-171
    • /
    • 2018
  • In this study, to analyze the detection of limit for sensitivity of the influenza rapid antigen test kit, the positive detection of limits were analyzed by serial dilution of influenza virus A and B type for five influenza rapid antigen test kits in Korea. As a result of analysis, visual measurement of type A were up to 1:8192 for the Wellsbio product and up to 1:4096 for the II product, up to 1:512 for the I and III products, and only 1:128 for the IV product, and type B were positive for up to 1:8192 for the Wellsbio product, up to 1: 4096 for the II product and up to 1:1024 for the I, III and IV products. For instrument readings with the same specimen, both A and B types were found to be positive for up to 1:8192 for the Wellsbio product, up to 1: 4096 for the II product, and up to 1:2048 for the I product. The sensitivity of the rapid antigen test for influenza differs greatly depending on the sampling area of the patient, infection period, specimen volume, etc. Therefore, it is necessary to observe exactly the collection timing and method of the specimen. And it is necessary further study to improve the sensitivity for influenza rapid antigen test.

Correlation Analysis of Reduction for Intra-Articular Calcaneal Fracture and Clinical Outcomes Using Postoperative Computed Tomography (수술 후 컴퓨터 단층촬영을 이용한 관절 내 종골 골절의 정복과 임상 결과 간의 연관성 분석)

  • Eom, Joon-Sang;Joo, Young-Deuk;Kim, Seong-Jun;Shin, Min-Ho;Lee, Dong-Oh;Jung, Hong-Geun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.165-172
    • /
    • 2014
  • Purpose: We evaluated the correlation of postoperative clinical outcomes and radiologic findings using computed tomography and simple X-ray in intra-articular calcaneal fractures. Materials and Methods: The current study is based on 41 feet, 38 patients with displaced intra-articular fracture who underwent surgical treatment with at least one year of follow-up. Evaluation of clinical outcome included American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) score, and subjective satisfaction. A simple X-ray was used in evaluation of preoperative and postoperative Gissane angle, B${\ddot{O}}$hler angle, and calcaneal fracture width. Computed tomography scan was performed for evaluation of preoperative and postoperative articular step-off and articular gap in all cases. Finally, we evaluated the correlation of the postoperative clinical outcomes and radiologic findings based on the measurement. Results: The average postoperative AOFAS score and VAS score was $84.1{\pm}8.5$ and $2.2{\pm}2.2$. Subjective satisfaction was excellent in 15 cases, good in 19 cases, and fair in seven cases. The average B${\ddot{O}}$hler angle was restored from $11.1^{\circ}$ to $24.7^{\circ}$(p<0.05), Gissane angle was changed from $121.0^{\circ}$ to $119.0^{\circ}$ (p>0.05), and the average width was restored from 45.8 to 35.0 mm (p<0.05). The average articular step-off and gap were decreased from 6.3 to 2.0 mm and from 11.1 to 4.6 mm, respectively (p<0.05). No significant correlations were observed between the clinical outcome and Gissane angle, B${\ddot{O}}$hler angle, and width, and there was no significant correlation between the clinical outcome and Sanders classification. However, postoperative articular step-off showed correlation with VAS and AOFAS score and articular gap showed correlation with VAS score. Conclusion: The clinical outcome did not show correlation with B${\ddot{O}}$hler angle and Gissane angle but did show correlation with anatomical reduction of the posterior facet joint.

Effective PPG Signal Processing Method for Detecting Emotional Stimulus (감성 자극 판단을 위한 효과적인 PPG 신호 처리 방법)

  • Oh, Dong-Gi;Min, Byung-Seok;Kwon, Sung-Oh;Kim, Hyun-Joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.393-402
    • /
    • 2012
  • In this study, we propose a signal processing algorithm to measure the arousal level of a human subject using a PPG(Photoplethysmography) sensor. From the measured PPG signals, the arousal level is determined by PPI(Pulse to Pulse Interval) and discrete-time signal processing. We ran psychophysical experiments displaying visual stimuli on TV display while measuring PPG signal from a finger, where the nature landscape scenes were used for restorative effect, and the urban environments were used to stimulate the stress. However, the measured PPG signals may include noise due to subject movement and measurement error, which results in incorrect detections. In this paper, to mitigate the noise impact on stimulus detection, we propose a detecting algorithm using digital signal processing methods and statistics of measured signals. A filter is adopted to remove a high frequency noise and adaptively designed taking into account the statistics of the measured PPG signals. Moreover we employ a hysteresis method to reduce the distortion of PPI in decision of emotional. Via experiment, we show that the proposed scheme reduces signal noise and improves stimulus detection.

The Effects of a Functional Movement Screen on Pain and Performance Ability in Professional Fencing Players (펜싱선수에서 통증과 수행 능력이 기능적 동작 검사에 미치는 영향)

  • Kim, Seong-Yeol;Lee, Je-Hoon;An, Seung-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.21-28
    • /
    • 2011
  • Purpose: The aim of this study was to investigate correlations between the Functional Movement Screen (FMS), pain, and performance ability in professional fencing players. Methods: Fifty-six athletes participated in this study. The pain group included those who had a score on a pain-related Visual Analogue Scale (VAS) of ${\geq}$20 and an Oswestry Disability Index (ODI) score ${\geq}$10). In the non-pain group, these scores were: VAS(<20), ODI(<10). The VAS and ODI were used to measure pain throughout the study. Performance ability included motor function of the lower extremities (as assessed by a Modified Functional Index Questionnaire, MFIQ), dynamic balance (Balance system, BS and Posture med, PM), flexor and extensor muscle strength of the lumbar region was recorded as maximal isometric strength. Results: Among athletes who had pain, 5 of 15(33.33%) showed impaired functional movement. Conversely, only 2 of 41(4.88%) of those who had no pain showed such impairment (FMS ${\leq}$14score). The athletes who had pain and who had an FMS score above 14 (10/56; 17.86%) showed a significantly higher score for extensor muscle strength of the lumbar compared with those with pain and an FMS score below 14 (5/56; 8.93%) were significant correlations between the FMS and pain (r=-0.40 to -0.42, p<0.01), the MFIQ (r=-0.33, p<0.05), dynamic balance (r=-0.27 to -0.40, p<0.05-0.01), muscle strength of the lumbar (r=0.27 to 0.29, p<0.05). Stepwise multiple regression analysis showed that the dynamic balance score (${\beta}{\beta}$=-0.41) had slightly more power in predicting FMS score than pain, motor function of lower extremity, or muscle strength. Conclusion: The FMS was significantly associated with values of pain, motor function of the lower extremities, dynamic balance, and muscle strength of the lumbar. However the FMS appears to lack relevance and reasonable evidence to suggest that it is an acceptable measurement tool for functional movement analysis.

The Relationships Between Low Vision and Socioeconomic Status in Korean Adults (저시력과 사회경제적 상태와의 관계)

  • Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2011
  • Purpose: The relativity of factors between low vision and socioeconomic status were investigated. This study represented the preliminary data for establishment of public eye health policy. Further, this report would encourage people to change the social attitudes about the eye health equity of the nation. Methods: The number of people (2,514 people) who have been tested the forced visual activity were examined as it was referred the Korea National Health and Nutrition Examination Survey (KNHNE) of 2009-year data. The prevalence rate of low vision of subjects which are related with house income, education level and occupations were conducted with ttest and chi square test. Besides, the Binominal Logistic Regression was conducted to measure the odds ratio of the subjects. Results: In outline, the prevalence rate of low vision was high with low house income, low education level and low function. The odds ratio represented that 2.77(95% CI, 1.72-4.47) at low house income group and 4.02(95% CI, 1.75-9.23) at the case of below primary school education level. Moreover, the results of unemployed group showed 3.65(1.14-11.68) from the odds ratio measurement. Conclusions: The eye health policy need be instituted which is broad and meticulous support to ease the eye health equity of low eye sight patients. For instance, the education about eye health, examination business of eye disease, and education of assistant units which are useful for low eye sight would suggest practical solution.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

Ex Vivo MR Diffusion Coefficient Measurement of Human Gastric Tissue (인체의 위 조직 시료에서 자기공명영상장치를 이용한 확산계수 측정에 대한 기초 연구)

  • Mun Chi-Woong;Choi, Ki-Sueng;Nana Roger;Hu, Xiaoping P.;Yang, Young-Il;Chang Hee-Kyung;Eun, Choong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.203-209
    • /
    • 2006
  • The aim of this study is to investigate the feasibility of ex vivo MR diffusion tensor imaging technique in order to observe the diffusion-contrast characteristics of human gastric tissues. On normal and pathologic gastric tissues, which have been fixed in a polycarbonate plastic tube filled with 10% formalin solution, laboratory made 3D diffusion tensor Turbo FLASH pulse sequence was used to obtain high resolution MR images with voxel size of $0.5{\times}0.5{\times}0.5mm^3\;using\;64{\times}32{\times}32mm^3$ field of view in conjunction with an acquisition matrix of $128{\times}64{\times}64$. Diffusion weighted- gradient pulses were employed with b values of 0 and $600s/mm^2$ in 6 orientations. The sequence was implemented on a clinical 3.0-T MRI scanner(Siemens, Erlangen, Germany) with a home-made quadrature-typed birdcage Tx/Rx rf coil for small specimen. Diffusion tensor values in each pixel were calculated using linear algebra and singular value decomposition(SVD) algorithm. Apparent diffusion coefficient(ADC) and fractional anisotropy(FA) map were also obtained from diffusion tensor data to compare pixel intensities between normal and abnormal gastric tissues. The processing software was developed by authors using Visual C++(Microsoft, WA, U.S.A.) and mathematical/statistical library of GNUwin32(Free Software Foundation). This study shows that 3D diffusion tensor Turbo FLASH sequence is useful to resolve fine micro-structures of gastric tissue and both ADC and FA values in normal gastric tissue are higher than those in abnormal tissue. Authors expect that this study also represents another possibility of gastric carcinoma detection by visualizing diffusion characteristics of proton spins in the gastric tissues.