• Title/Summary/Keyword: vibro-compaction

Search Result 8, Processing Time 0.031 seconds

Settlement Behavior of Foundation Rubble-mound by Vibro-Compaction (진동다짐에 의한 기초사석의 침하거동)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4C
    • /
    • pp.127-136
    • /
    • 2011
  • The settlement of a compaction plate resting on the surface of rubble-mound and subjected to a vibrating vertical load can be characterized by a transient amplitude and a plastic settlement. As long as the maximum imposed load does not exceed the bearing capacity of the rubble-mound, plastic settlement will approach an ultimate value and essentially steady-state vibration will ensue. For the settlement behavior by vibro-compaction, most laboratory experiments were conducted on laterally confined samples with loads over the full surface area or on samples placed on a vibrating table. In the field, the loads cover only a small fraction of the surface area. In this study, crushed stones are loaded with the same as field condition. According to the vibro-compaction experiments on crushed stone, it was found that approximately 90% of total settlement occur within 2 minutes and plastic settlement increases with increasing cyclic stress levels including static and dynamic stress. A compaction equation on which the number of load cycles, amplitude of plate, settlement, width of plate, and cyclic stress are related each other is proposed.

An Experimental Study on the Characteristics of Vibro-compaction of Crushed Stones (쇄석의 진동다짐 특성에 관한 실험적 고찰)

  • Jeong, Gil-Soo;Park, Byung-Soo;Hong, Young-Kil;Yoo, Nam-Jae
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.89-94
    • /
    • 2004
  • This Study is results of experimental works to investigate the characteristics of vibro-compaction of crushed stones having coarse grain sizes. For testing material, crushed stone, sieved within very narrow ranges of grain size distribution, was used. Cyclic loading apparatus was used to apply cyclic loading to the specimen prepared in the mold. Tests were performed by changing the ratio of the maximum to the minimum stress, frequency and the magnitude of the maximum and the minimum stresses. Settlement of specimen due to cyclic loading was measured to analyze the compaction efficiency and sieve analysis test after cyclic loading test was also carried out to find the crushing rate of the specimen. As results of cyclic loading test, normalized settlement in terms of specimen height tends to be converged around loading cycle number of 1500. The magnitude of normalized settlement is in the range of 3.11 ~ 8.57%. The crushing rate is in the range of 4.46 ~ 8.78%. Normalize settlement and the crushing rate tend to increase with decreasing the ratio of the maximum to the minimum stresses and they tend to increase with increasing the frequency and the magnitude of the maximum and the minimum stresses for the given ratio. In conclusions, compaction rate of crushed stone is controlled by the dynamic stress (difference between the maximum and the minimum stresses) and the crushing rate is dominated by applied energy to the specimen.

  • PDF

Behavior of Soft Ground Reinforced by Vibro Crushed-Stone Compacted Pile In Railroad Site (배후철도부지 진동쇄석다짐말뚝(VCCP) 개량지반의 거동)

  • Park, O-Sung;Shim, Seong-Hyen;Han, Sang-Jae;Cho, Kook-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1376-1379
    • /
    • 2006
  • Vibro crushed-stone compacted pile (VCCP) method is one of a ground improvement technique by a vibro compaction in vertical direction with crushed stone to build up stone pile foundation in other to ensure stability of soft ground. In spite of its long applied history in geotechnical engineering division, most of studies have not been based on the reliable In-situ condition but on the laboratory tests including model tests. These model tests can express standard and ideal behavior but exceptional status that can be occur in the ground cannot be considered efficiently. This study performed the the series of trial construction to investigate the effect of VCCP method on the improvement of soft ground expecially in railroad construction site.

  • PDF

Study of the Anisotropy of the Roller Compacted Concrete (RCC) for Pavement

  • Zdiri, Mustapha;Abriak, Nor-edine;Ouezdou, Mongi Ben;Neji, Jamel
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.1
    • /
    • pp.45-49
    • /
    • 2010
  • The roller compacted concrete (RCC) is supposed to be isotropic, whereas the compaction of this material, which is achieved using the same machines used for the soil, appears only unidirectional, making the RCC an anisotropic material. In this experimental work, the influence of the phenomenon of compaction on the isotropy of the RCC is studied. This study was carried out through an evaluation of the compressive strengths and ultrasonic tests which were used for measurements of the elastic modulus and the dynamic Poisson's ratio of the RCC as well as a qualitative judgement of the RCC aspect at the hardened state. The results of this work proved the anisotropy of the RCC and they showed the sensitivity of the mechanical strengths and the elastic modulus to the compaction direction.

A Study on the Field Application Porous Concrete Pavement (투수성콘크리트포장의 현장적용에 관한 연구)

  • ;Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.613-619
    • /
    • 1997
  • The present study has an objetive to define the characteristic of the Porous Concrete to be used in the resistant layers of the pavement. Up to the moment there is no material which is capable which is capable of satisfying the mechanical resistances and drainability, two characterstics which interves, and a detailled study has been carried out on the same order to obtain the porous concrete of this study. such as: Mode and time of compaction. type of cement, water/cement ratio, maxium size of aggregates, sieve test. incorporation of some additives and additions etc., among them emphasizing the use of a method of compaction vibro-compression in the laboratory with which an optimum compacting was reached, and can be obtanied on the site with a spreader rated with double tamper. With this porous concrete for this study whose dominating characteristics is the drainability jointly with a high mechanical resistance. a safe and silence firm is obtained, with can be a great diffusion in the near future, for its application on the pavements. Based on these works carried out, there was the first experience in the world of field application with 25cm of resistance layer of Porous Concrete Pavement in Salamanca, Spain.

  • PDF

Case History of Low Vibration and Low Noise Granular Pile Method in the Area of Incurred the Popular Enmity (민원발생지역에서의 저진동$\cdot$저소음 Granular Pile의 시공사례)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.176-181
    • /
    • 2003
  • Damages by vibration and noise due to the construction performance are increasing. The rise of construction demand and enlargement of equipments are major reasons of this damage. As a result, the enmity of the people is provoked and this appears to be an obstacle of construction work. Especially, in case of ground improvement construction. Casing pipe is inserted into the Sand Drain, Sand Compaction Pile and Vibrated Crushed-stone Pile by vibration power when carrying out. Hence, a pillar is formed and it creates vibration and noise. This causes a lot of restrictions to construction condition. The low Vibration and low noise construction equipments uses earth auger and hydrulic cylinder for insertion and chopping operation instead of vibro hammer, which is the source of vibration and noise. This minimize ground disturbanceand decrease vibration and noise successfully, but increase chopping effect greatly. Thus, this new equipment is not only suitable for environment but also excellent engineering method of construction.

  • PDF

Nuclear Design Methodology of Fission Moly Target for Research Reactor

  • Cho, Dong-Keun;Kim, Myung-Hyun;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.365-374
    • /
    • 1999
  • A nuclear design of fission moly production targets for a research reactor, HANARO was peformed. It was found that the use of MCNP-4A, ORIGEN-2 code was reliable for the analysis of production characteristics of $^{99}$ Mo in a target fuel at an irradiation holes. A parametric study was done for the optimization of target location, target dimension, target shape and fuel materials. It was shown that a fuel thickness was the most sensitive parameters and electro-deposited target gave the highest 99Mo yield ratio. A pellet target with vibro-compaction powder, however, showed the largest production capacity and better engineering feasibility even with less yield ratio. Ten kinds of optimized target design for both LEU and HEU satisfied all the given design constraints. The most favorable design was the HEU ring-shaped electro-deposited target, considered the safety limit, production yield, chemical process easiness, yield ratio, and amount of radioactive waste.

  • PDF

A Case Study of Caisson Typed Bridge-Foundation Fabrication and Installation in Ul-san Newport Breakwater Project (케이슨식 교량기초 제작 및 거치 시공사례 -울산 신항 방파제현장 시공 사례를 중심으로-)

  • JANG BYUNG-SOO;SIN SUNG-GWEN;KIM DUCK-HO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.45-50
    • /
    • 2004
  • The method of caisson typed bridge-foundation fabrication and installation applied in Ul-san newport breakwater project is throughly carried out to compact QRR mound vibro-hammer step by step to minimize settlement through stability check. Floating Dock was mobilized for caisson fabrication due to limited site area. fabricated caisson on the Floating Dock was towed to the deeper area of 8m water depth to be launched, and Floating Crane assisted launching and installation work of the caisson. finally water filling was done followed by surveying work to permanent installation.

  • PDF