• 제목/요약/키워드: vibrator

검색결과 296건 처리시간 0.023초

초음파 리니어 모터의 설계와 ANSYS에 의한 변위량해석 (Design and Displacement Analysis by ANSYS of Ultrasonic Linear Motor)

  • 김태열;강도원;김범진;박태곤;김명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.300-302
    • /
    • 1999
  • The standing waves of the fourth bending mode of vibration and first longitudinal mode of vibrator were utilized to construct a ultrasonic linear motor. The geometrical dimensions of the vibrator were determined by Euler-Bernoulli theoty. FEM(finite element method) employed to calculate the vibration mode of the metal-piezoceramic composite thin plate vibrator. ANSYS was used to design positions of the projections and calculate displacement of vibrator.

  • PDF

영구자석 여자 횡축형 선형 전동기(TFLM)를 이용한 가진기 제어 (A Control of Vibrator Using PM Excited Transverse Flux Linear Motor)

  • 임태윤;강도현;김종무;김동희
    • 전력전자학회논문지
    • /
    • 제7권3호
    • /
    • pp.281-288
    • /
    • 2002
  • 본 논문은 영구자석 여자 횡축형 선형 전동기(TFLM)를 이용한 가진기 제어 시스템을 구현하고자 한다. 제안된 가진기는 대상 물체에 정격 전류에서 최대 700[N]의 가진력과 넓은 변위 및 주파수 운전 범위를 갖는 진동운동을 제공한다. 또한 가진기에 적용된 TFLM은 구조적으로 높은 추력비(전동기 추력/전동기 중량=N/Kg)를 가지므로 전체 시스템의 부피가 감소된다. 따라서 기존의 유압식 가진기를 제안한 가진기로 대체할 경우 효율 및 유지, 관리면에서 많은 장점이 있다. 가진 제어를 위한 제어기의 입력은 가진 주파수와 변위이며 제어량은 이동자의 순시 위치와 속도이고 출력은 가진기에 인가되는 전류이다. 이 전류는 전압형 PWM 컨버터로 제어된다 우선 가진기 제어시스템의 제어 알고리즘과 운전 특성을 고찰하고 해석하기 위해 동적 시뮬레이션을 수행한 후 DSP 제어기와 IGBT PWM 컨버터를 구현하여 실제 실험 결과와 비친, 검토하였다.

휘담식 진동기 골반수기로 개선된 급성 요통 증후군으로 인한 보행장애 증례 (A Case Report of Gait Disturbance due to Acute Low Back Pain Syndrome improved with Whidam's Vibrator Pelvic Sugi Therapy)

  • 정재훈;필감매;나삼식
    • 대한의료기공학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2022
  • Objective : The purpose of this study is to report the results of treating patients with acute low back pain syndrome who are difficult to walk with Whidam's Vibrator Pelvic Sugi Therapy. Methods : We used combinations of korean medicine such as herbal medicine, acupuncture, cupping therapy, and thermal therapy. At the same time, the patient was treated with Whidam's Vibrator Pelvic Sugi Therapy. The first period of hospitalization was 14 days and the second period was 54 days. At the second hospitalization, back pain recurred and was unable to walk. At the first hospitalization, L5-S1 HIVD and L4-5 Mild HIVD were diagnosed on lumbar MRI, and there was no abnormality in blood tests. Results : By relieving muscle tension and restoring the weakened muscle elasticity with herbal treatment and Whidam's Vibrator Pelvic Sugi Therapy, back pain decreased and the inability to walk gradually improved, making it possible to walk on its own. Conclusions : The results of standing and walking on one's own were obtained by relieving muscle tension and restoring weakened muscle elasticity in acute back pain syndrome with gait disturbance diagnosed with lumbar herniated intervertebral disc through korean medicine treatment and Whidam's Vibrator Pelvic Sugi Therapy. Whidam's Vibrator Pelvic Sugi Therapy is thought to help acute back pain by restoring muscle elasticity and strengthening muscle strength. In the future, it is expected that additional clinical studies will be conducted on various pain diseases with Whidam's Vibrator Pelvic Sugi Therapy.

2차원 공구진동기구의 변위 해석 (A Displacement Analysis of 2-Dimensional Tool Vibrator)

  • 손성민;임한석;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.898-901
    • /
    • 2000
  • In this paper, the theoretical tool displacement and surface roughness are analyzed based on the tool locus of a 2-dimensional tool vibrator. At first, the effects assuming no structural deformation of such variables as frequency, amplitude and phase difference that determine tool loci are simulated. The results show that larger amplitude and/or higher frequency makes better surface. However, a real tool vibrator has the structural deformation, much or less, depending on the excitation frequency. Applying FEM analysis to the deformation of a designed 2D tool vibrator according to the excitation, it has been proved that in this case the displacement is 5${\mu}{\textrm}{m}$ at 1KHz and almost 0 at 20KHz even under the same excitation amplitude.

  • PDF

초음파 트랜스듀서의 종진동을 이용한 알루미늄 와이어 용접 (Aluminum Wire Bonding by Longitudinal Vibration of Ultrasonic Transducer)

  • Lee, G.B.;Kim, H.S.
    • 한국정밀공학회지
    • /
    • 제13권11호
    • /
    • pp.38-45
    • /
    • 1996
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. Specially, the method utilizes the longitudinal vibration of ultrasonic transducer composed of piezoelectric vibrator and horn. This work investigates the design conditions affecting the dynamic characteristics through the theretical and experimental analysis. It conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. The integrated modeling is conducted via a combbination of dynamic identification of piezoelectric vibrator and theroretical analysis of horn. Then comparison is made for theroretical and experimental results of the dynamic characteristics of the ultrasonic transducer comprised of piezoelectric vibrator and horn. Form the results of the comparison we develop the design technique of ultrasonic transducer using dynamic characteristics analysis and propose the possibility of ultrasonic bonding considering the optimal conditions for the longitudinal vibration of ultrasonic transducer and other conditions.

  • PDF

초음파 진동자를 이용한 족욕기용 구동회로 제작 및 특성 (Fabrication and charateristics of the foot-spa driving circuit using ultrasonic vibrator)

  • 장은성;김흥규;이상호;류주현;황락훈;정회승;정광현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.705-709
    • /
    • 2004
  • In this study, the foot-spa driving circuit using ultrasonic vibrator was manufactured The used ultrasonic vibrator was PSN-PMN-PZT ceramic with the radius of $25{\Phi}$ and the thickness of 2, 2.5, 3, 3.5 and 4mm, respectively. Resonent frequency for driving ultrasonic vibrator at the fabricated circuit was generated using the self exciting and the external exciting methods. Fabricated foot-spa showed the best condition at the resonent frequency of 1.130MHz and the ceramic thickness of 2.0mm. That is, when the foot-spa was operated for 360 min. at $0.5\ell$ water, temperature increase of water was $14^{\circ}C$ at the self exciting method and $16^{\circ}C$ at the external exciting methods, respectively.

  • PDF

광대역 수중 음향 압전 진동체의 등가회로 모델링 (Equivalent Circuit Modeling of Wideband Underwater Acoustic Piezoelectric Vibrator)

  • 조치영;김원호;윤형규
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.645-652
    • /
    • 1996
  • In this paper an identification method is presented to obtain the equivalent electric circuit model of a wideband underwater acoustic piezoelectric vibrator. Unknown parameters involved in the equivalent circuit are indentified using the measured electrical admittances in air. The proposed method is applied to an example transducer. The validity of equivalent circuit model is demonstrated by the comparison between the experimental measurements and analytical calculations of TVR(transmitting voltage response) in water.

  • PDF

초음파 리니어 모터의 설계와 유한요소 해석 (Design and FEM Analysis of Ultrasonic Linear Motor)

  • 김태열
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.210-215
    • /
    • 1999
  • The standing waves of the fourth bending ode of vibration and the first longitudinal mode of vibration were utilized to construct a ultrasonic linear motor. The geometrical dimensions of the vibrator were determined by Euler-Bernoulli theory. FEM(finite element method) employed to calculate the vibration mode of the metal-piezoceramic composite thin plate vibrator. ANSYS was used to design positions of the projections and calculate displacement of vibrator.

  • PDF

전극 분할 적층형 압전변압기의 전기적 특성 (Electrical Properties of a Laminated Piezoelectric Transformer with the Divided Electrodes)

  • 이용국;이상철;허두오;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1140-1142
    • /
    • 1995
  • The transformer is fabricated with two piezoelectric vibrator with the divided electrodes and adhesive insulator. We applied the electric input to the driving vibrator in parallel and connect the output voltage to the generating vibrator in series to the resistor load near its fundamental resonance frequency. Then we investigate output voltage in series twice as large as in parallal. Moreover we investigate the load characteristics at resonance frequencies under various resistor and the frequency characteristics near the resonance frequency under no load. Its equvalent circuit is derived from the Mason's model of a thickness-driven piezelectric vibrator. By its equevalent circuit, symbolic expressions for input impedances, voltage ratios, resonance frequencies, and bandwidths have been derived. The values calculated from those symbolic exprssions are shown to agree well with the measurement values.

  • PDF

치과용 골 수술기의 초음파 진동자 설계 및 평가 (Evaluation and Design of Ultrasonic Vibrator for Dental Surgery)

  • 박기문;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.102-108
    • /
    • 2016
  • A dental ultrasonic surgical instrument, commercially known as a scaler, is a high-value-added advanced technology that is used for tartar removal, implant operations, and gum and jaw bone surgery. In this study, the piezoelectric phenomenon for making linear motion associated with input electrical signals was studied, and the behavior of the ultrasonic vibrator was investigated by using the commercially available finite element program ANSYS(R) for the purpose of designing dental surgery tools. Modal analysis was carried out, and the optimal frequency range was calculated from the analyzed results. The ultrasonic vibrator was then redesigned based on the calculated optimal frequency range. The performance of the system was tested, and consequently, the proposed methodology was proven useful in vibrator design.