• Title/Summary/Keyword: vibration reduction and control

Search Result 487, Processing Time 0.029 seconds

An Experimental Study on the Structural Vibration Control Using Orificed Fluid Dampers (Orificed Fluid Dapper를 이용한 구조물 진동계어의 실험적 연구)

  • 정태영;임채욱;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.364-372
    • /
    • 2001
  • An orifices fluid damper(OFD) having the capacity of about 2 tons was designed and fabricated and applied to a 6-story steel structure under random excitation and seismic excitation for the confirmation of its validity on structural vibration absorbtion. The experimental results demonstrated that the addition of an OFD to the test structure is very effective in reduction of vibration level of the higher modes as well as the fundamental mode. Maxwell model was adopted to described the frequency-dependent characteristics of the fabricated OFD and the numerical simulation was carried for the test structure. It was confirmed that the experimental and numerically simulated results agree well.

  • PDF

Active Control of Noise Transmitted through Ventilation Openings of the Machinery Room of Refrigerator (무부하 압축기에 의한 냉장고 기계실 소음의 능동제어)

  • Koo, Jung Mo;Jeong, Weui Bong;Kim, Tae Hoon;Hong, Chinsuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.475-482
    • /
    • 2016
  • The active control of noise generated by the compressor and transmitted out of the machine room through the windows is implemented based on the FIR filter. The machine room contains most of noise sources of electric home appliances, air-conditioners and refrigerators, for example. To actively reduce the noise from the machinery room. In this paper, the transfer function of the controller for minimization of the acoustic power transmitted through the windows is mathematically formulated. The transfer functions required for implementation of the active controller are the measured. The measurements are conducted in this initial stage under the operation of the compressor with no load. For improvement of the reliability of the transfer function of the compressor to the acoustic power, additional operational measurements are performed. The real time controller is implemented based on the FIR filter using the measured transfer functions and the performance of the active controller is estimated. Control performance is measured about 3 dB ~ 10 dB in reduction of the sound power at the peaks of the compressor noise.

Exhaust Noise Control of Marine Diesel Engine by using Resonator Type Silencer (공명형 소음기를 이용한 박용 디젤엔진 배기 소음 제어)

  • Lee, Tae-Kyung;Joo, Won-Ho;Bae, Jong-Gug
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.350-354
    • /
    • 2008
  • Low frequency exhaust noise of marine diesel engine is one of the most important noise sources in vessels. However, conventional absorptive silencers are limited because the absorptive material is not effective in low frequency range. In the paper, exhaust noise control of marine diesel engine has been studied by using the resonator type silencer, which was composed of concentric hole-cavity resonators. The acoustic performance of the resonator type silencer was verified by the insertion loss measurement considering flow effect. Consequently, its high performance, about $5{\sim}8dB$ noise reduction, in the low frequency range was confirmed by insertion loss measurements conducted in the ship.

  • PDF

Investigations on seismic performance of nuclear power plants equipped with an optimal BIS-TMDI considering FSI effects

  • Shuaijun Zhang;Gangling Hou;Chengyu Yang;Zhihua Yue;Yuzhu Wang;Min He;Lele Sun;Xuesong Cai
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2595-2609
    • /
    • 2024
  • This paper introduces a base isolation system-tuned mass damper inerter (BIS-TMDI) hybrid system to the AP1000 nuclear power plant (NPP), which reduces seismic damage potential of the NPP structure. The effects of fluid-structure interaction (FSI) caused by the passive containment cooling system water storage tank (PCCWST) on NPP's seismic performance are investigated. The FSI of water tank theoretical model is considered based on the Housner's model, and a series of time history analyses are performed to prove the rationality of the proposed model. Three single-objective optimization strategies are employed to minimize the relative displacement variance and absolute acceleration variance of the upper structure, as well as the filtered energy index (FEI). Furthermore, a multi-objective optimization strategy considering all these three indexes is proposed to obtain optimal parameters of vibration control. The influence of vibration control strategies on the relative deformation and acceleration of the upper structure is explored with various water level ratios. The analytical results indicate that the proposed BIS-TMDI strategy has significantly reduced the NPP structure's seismic response. The effectiveness of the vibration control strategy is influenced by the water level ratio, emphasizing the significance of designing an appropriate water level ratio to reduce NPP structure's seismic response.

The Control Performance of the Active Control System with Insufficient Number of Control Sources and Sensors for the Reduction of Duct Noise (고차모드 수보다 적은 수의 제어음원과 센서를 이용한 덕트 방사소음 제어시스템의 제어성능)

  • 윤두병;김양한;정균양;조대승
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1030-1036
    • /
    • 1998
  • When the lateral dimensions of a duct is larger than or comparable to the wavelengths of Interest, higher order modes propagate in the duct. These modes will be radiated and produce noise. A number of sensors and actuators for control of radiating noise from the duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and control sources than required. In this work, by theoretical analysis, the control performance of such a kind of system is investigated in terms of sound-field variables and control system variables. The possible maximum and minimum value. mean and variance of residual acoustic potential energy are derived for the set of primary sound fields.

  • PDF

Dynamic Analysis of Building Structures with Viscoelastic Dampers (탄성감쇠를 가진 건축구조물의 동적해석)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.196-203
    • /
    • 1998
  • Viscoelastic dampers have been successfully applied to building structures for reduction of vibration induced by wind or earthquakes. But accurate estimation of responses of building structures with viscoelastic dampers is very difficult, because the properties of viscoelastic damper is dependent on temperature and frequency of vibration. For efficient control of building vibration, required damping of viscoelastic damping device need be estimated and dynamic analysis method which can estimate the response of building structure with viscoelastic damper system is indispensable. In this paper, an efficient dynamic analysis method of a building structure with viscoelastic dampers is proposed. Efficiency and accuracy of the proposed method are verified comparing analytic results with shaking table test results using reduced building models.

  • PDF

Torque Ripple Reduction based on Flux Linkage Harmonics Observer for an Interior PM Synchronous Motor including Back EMF Harmonics (왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 쇄교자속 고조파 관측기를 이용한 토크리플 저감)

  • Jin, Yong-Sin;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • The mechanical vibration of a PM synchronous motor at low speeds due to the back emf harmonics may be serious problems in some application such as MDPS(Motor driven power steering), electric vehicles. In this paper, torque ripple reduction for an interior PM synchronous motor including back emf harmonics is proposed. The dq flux linkage harmonics of the permanent magnet are estimated on real time by using the dq currents of the real system and the model of the MRAS observer. Based on the estimated flux linkage harmonics, the dq harmonic currents for reducing the torque ripples are compensated on the dq reference currents. The estimation of the flux linkage harmonics by the MRAS observer and the torque ripple reduction of the proposed algorithm was verified by the simulation and experiment.

Protective systems for high-technology facilities against microvibration and earthquake

  • Yang, Jann N.;Agrawal, Anil K.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.6
    • /
    • pp.561-575
    • /
    • 2000
  • Microvibration of high technology facilities, such as semiconductor plants and facilities with high precision equipments, due to nearby road and rail traffic has attracted considerable attention recently. In this paper, a preliminary study is conducted for the possible use of various protective systems and their performance for the reduction of microvibration. Simulation results indicate that passive base isolation systems, hybrid base isolation systems, passive floor isolation systems, and hybrid floor isolation systems are quite effective and practical. In particular, the performances of hybrid floor isolation systems are remarkable. Further, passive energy dissipation systems are not effective for the reduction of microvibration. Finally, the protections against both microvibration and earthquake are also investigated and presented.

Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity (음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어)

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Koo, Ja-Choon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

Payload-Swing Suppression of a Container Crane: Comparison Between Command Shaping Control and Optimal Control

  • Do, Huh-Chang;Shik, Hong-Keum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.54.2-54
    • /
    • 2001
  • In this paper two control strategies, command shaping control and optimal control, which aim to the reduction of the residual vibrations of the payload in a container crane system are investigated. Both control methods are open loop control. Due to unmodeled dynamics of the plant and disturbances like initial sway and wind, some residual sway always exists at the end of trolley movement. Command inputs are designed to achieve the control objectives including minimal residual vibration and robustness in the presence of unmodeled dynamics. Simulation results of various command inputs are compared in terms of arrival time, residual sway angle, robustness, and maximum sway distance during the traveling. Command shaping method provides a more competent tool than optimal control.

  • PDF