• 제목/요약/키워드: vertical wall

검색결과 1,032건 처리시간 0.025초

영구벽체로 사용하는 지하연속벽 수직시공이음부의 설계방법 (Design Considerations and Method for Vertical Construction Joints of Slurry Walls Used as Permanent Basement Walls)

  • 이정영;김승원;김두기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.395-396
    • /
    • 2023
  • The current building structural standards present design requirements for the vertical construction joint of a slurry wall when it is used as a permanent wall. This paper proposes design methods and considerations according to the requirements of the relevant standards.

  • PDF

철근콘크리트 프리캐스트 대형판 접합부의 설계 및 해석 (Design and Analysis on The Connections of RC Precast Large Panel)

  • 박강근
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.85-92
    • /
    • 2006
  • 본 연구에서는 철근콘크리트 프리캐스트 대형판의 접합부 설계방법 및 해석방법에 대해서 연구를 수행하였다. 접합부의 설계방법은 수평접합부와 수직접합부의 구조적 거동에 대한 안정성 및 일체성을 확보하기 위한 설계법을 제시하였고, 접합부의 해석은 강체스프링 모델에 의한 탄소성해석을 수행 하였다.

  • PDF

가열 수직 평판과 마주보는 전자모듈의 복사 및 대류 냉각에 대한 실험적 고찰 (Experimental Study on the Radiative and Convective Cooling of Electronic Modules opposed to a Heated Vertical Plate)

  • 최인수
    • 한국산업융합학회 논문집
    • /
    • 제8권2호
    • /
    • pp.105-112
    • /
    • 2005
  • The characteristics of natural convection heat transfer combined with radiation in a vertical parallel plates has been investigated experimentally. The vertical channel is consisted with a heated wall and three protruding heating sources attached on the opposite wall. The cooling of modules has been experimented with heating the wall as well as modules themselves at different aspects ratios and heating fluxes. As the location of module is higher, the temperature becomes higher, but the increasement is smaller. When the aspect ratio is lower than 26, its effect on the temperature is not significant rather than that of the radiation heat transfer. Furthermore, the correlation of Nusselt number with the Rayleigh number are attempted, but additional treatment is needed to accomodate the cases of heating module and/or opposite wall.

  • PDF

환경친화적 블록식 보강토옹벽의 설계 및 시공사례연구 (Case Study of Environmental Segmental Retaining Wall(SRW) Using Greenstone Block)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제7권6호
    • /
    • pp.19-28
    • /
    • 2004
  • Segmental Retaining Wall(SRW) has been variously applying in Civil and Architecture construction. Recently, the application of environmental element in all type's structures came to essential requirement, and the construction cases of retaining wall using reinforced soil and block are more increased than the past. But, this trend more widely was spread environmental element as landscape work for the backside of reinforced retaining wall as well as block itself. New environmental block, Greenstone Block, developed to apply of this tendency. The retaining wall system using Greenstone can be environmental constructing at both block itself and backside of retaining wall. The material tests, the axial compressive strength test of block and bending test of fiber-pipe, exercised to design and construction of vertical SRW, which were satisfied NCMA standard. Through this procedure, Rewall (ver 1.0) was developed, which can be automation design of SRW including internal stability, external stability and local stability. And these can be considered setback of retaining wall, as well the examples of vertical retaining wall using block presented to satisfying the follows; strength of reinforced geotextile, height of retaining wall, surcharge, types of backfill and groundwater level etc. Many problems investigated on after or before of construction were due to local failure, insufficiency of bearing capacity and groundwater level. Especially, the local failure was many occurred to during compaction or after construction, and the cases of SRW construction is similar to the results of model test on vertical SRW.

The vertical spanning strip wall as a coupled rocking rigid body assembly

  • Sorrentino, Luigi;Masiani, Renato;Griffith, Michael C.
    • Structural Engineering and Mechanics
    • /
    • 제29권4호
    • /
    • pp.433-453
    • /
    • 2008
  • The equation of motion of a one way (vertical) spanning strip wall, as an assembly of two rigid bodies, is presented. Only one degree of freedom is needed to completely describe the wall response as the bodies are assumed to be perfectly rectangular and are allowed to rock but not to slide horizontally. Furthermore, no arching action occurs since vertical motion of the upper body is not restrained. Consequently, the equation of motion is nonlinear, with non constant coefficients and a Coriolis acceleration term. Phenomena associated with overburden to self weight ratio, motion triggering, impulsive energy dissipation, amplitude dependency of damping and period of vibration, and scale effect are discussed, contributing to a more complete understanding of experimental observations and to an estimation of system parameters based on the wall characteristics, such as intermediate hinge height and energy damping, necessary to perform nonlinear time history analyses. A comparison to a simple standing, or parapet, wall is developed in order to better highlight the characteristics of this assembly.

수직벽화재의 수치 시뮬레이션 I. 수직벽 난류자연대류 (Numerical Simulation of Vertical Wall Fires I. Turbulent Natural Convection Along Vertical Wall)

  • 박외철;아노드 트루베
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.181-187
    • /
    • 2008
  • 수직벽 화재의 연구에 사용할 전산유체역학 시뮬레이터를 검증하기 위해 수직벽 자연대류의 수치 시뮬레이션을 수행하였다. 높이 4m의 등온 수직벽에 형성된 난류 경계층에서의 속도 및 온도 분포의 계산치를 측정치와 비교하였다. 시뮬레이터에 포함된 매개변수의 기본 값을 그대로 적용한 경우, 경계층 유동이 층류로 나타남에 따라 난류 자연대류를 예측하는데 실패하였다. 매개변수의 조사를 통해 격자크기 $\Delta$x=5mm, ${\Delta}y={\Delta}z=10mm$와 대와동모사(large eddy simulation)의 스마고린스키 상수(Smagorinsky constant) $C_s$=0.1을 선정하였다. 난류혼합이 미흡하였지만, 벽면근처에서의 속도분포와 최대속도, 그리고 난류 경계층 내 온도분포가 실험과 잘 일치하였다.

Experimental and numerical study on the earth pressure coefficient in a vertical backfilled opening

  • Jian Zheng;Li Li
    • Geomechanics and Engineering
    • /
    • 제36권3호
    • /
    • pp.217-229
    • /
    • 2024
  • Determining lateral earth pressure coefficient (EPC) K is a classic problem in geotechnical engineering. It is a key parameter for estimating the stresses in backfilled openings. For backfilled openings with rigid and immobile walls, some suggested using the Jaky's at-rest earth pressure coefficient K0 while other suggested taking the Rankine's active earth pressure coefficient Ka. A single value was proposed for the entire backfilled opening. To better understand the distributions of stresses and K in a backfilled opening, a series of laboratory tests have been conducted. The horizontal and vertical normal stresses at the center and near the wall of the opening were measured. The values of K at the center and near the wall were then calculated with the measured horizontal and vertical normal stresses. The results show that the values of K are close to Ka at the center and close to K0 near the wall. Furthermore, the experimental results show that the horizontal stress is almost the same at the center and near the wall, indicating a uniform distribution from the center to the wall. It can be estimated by analytical solutions using either Ka or K0. The vertical stress is higher near the center than near the wall. Its analytical estimation can only be done by using Ka at the center and K0 near the wall. Finally, the test results were used to calibrate a numerical model of FLAC2D, which was then used to analyze the influence of column size on the stresses and K in the backfilled opening.

겨울철 버블시트 포설방법 변화에 따른 벽식구조 수직철근의 온도 특성 (Temperature Properties of Vertical Reinforcements in Wall Structures in Relation to the Different Methods of Bubble Sheet Installation in Winter)

  • 김태우;이제현;경영혁;이정교;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.11-12
    • /
    • 2017
  • This study aims to analyze the properties of the temperature change in vertical reinforcements in outdoor wall structures in winter in relation to the different methods of bubble sheet installation, and to subsequently determine the possibility of initial frost damage to the concrete as a result of low temperature. As for the experimental variables, double bubble sheets were used as curing materials, and the curing method was to model the part where the slab and the wall intersect and the rebar is exposed, and to measure the change of temperature around the exposed rebar in accordance with the change of the coating curing. It was found that by employing curing method B, which is to install the bubble sheet between the vertical reinforcements, the most vulnerable area, which is 50mm below(④) the surface of the concrete, would be lowered to sub-zero temperature 20 hours later than when using curing method A, and that therefore it is more effective to install the bubble sheet between the vertical reinforcements for the prevention of initial frost damage.

  • PDF

추적자조사기법을 활용한 사용종료매립장 연직차수벽 성능평가 (Performance Evaluation of Close Waste Landfill Vertical Slurry Wall(SCW) by Tracer Method)

  • 이동건;오영인;김관호;조숙희;박은숙
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1245-1252
    • /
    • 2010
  • Many industrialized countries are confronted with a difficulty about reuse of closed waste landfill. facilities. Especially, the demand of closed waste landfill maintenance and reuse nearby urban area has been increased, because of the shortage of usable land and extend of urban area. For the safe reuse of closed waste landfill, the most important check point is the effect of waste landfill on environment abound them. However, the non-sanitary closed waste landfill generally have no leachate lining system, therefore, the in-situ lining system such as sheet-pile, and vertical slurry wall etc. was needed to prevent the leachate outgoing from the waste landfill. In this paper present the case history of performance evaluation of vertical slurry wall by tracer tests.

  • PDF

Effect of vertical reinforcement connection level on seismic behavior of precast RC shear walls: Experimental study

  • Yun-Lin Liu;Sushil Kumar;Dong-Hua Wang;Dong Guo
    • Earthquakes and Structures
    • /
    • 제26권6호
    • /
    • pp.449-461
    • /
    • 2024
  • The vertical reinforcement connection between the precast reinforced concrete shear wall and the cast-in-place reinforced concrete member is vital to the performance of shear walls under seismic loading. This paper investigated the structural behavior of three precast reinforced concrete shear walls, with different levels of connection (i.e., full connection, partial connection, and no connection), subjected to quasi-static lateral loading. The specimens were subjected to a constant vertical load, resulting in an axial load ratio of 0.4. The crack pattern, failure modes, load-displacement relationships, ductility, and energy dissipation characteristics are presented and discussed. The resultant seismic performances of the three tested specimens were compared in terms of skeleton curve, load-bearing capacity, stiffness, ductility, energy dissipation capacity, and viscous damping. The seismic performance of the partially connected shear wall was found to be comparable to that of the fully connected shear wall, exhibiting 1.7% and 3.5% higher yield and peak load capacities, 9.2% higher deformability, and similar variation in stiffness, energy dissipation capacity and viscous damping at increasing load levels. In comparison, the seismic performance of the non-connected shear wall was inferior, exhibiting 12.8% and 16.4% lower loads at the yield and peak load stages, 3.6% lower deformability, and significantly lower energy dissipation capacity at lower displacement and lower viscous damping.