대형수직펌프에서의 경계조건 변화에 따른 진동 특성

  • 배춘희;조철환;양경현;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.779-781
    • /
    • 2005
  • In this paper, Firstly, it is shown that the bending mode vibration source of vertical pump system is comparatively large because resonance. Secondly in order to reduce the bending mode vibration of vertical pump, The improvement of some boundary condition have been developed and its effectiveness is investigated as appling it at the vertical pump system pratically.

  • PDF

수직형 건식 진공 스크류 펌프의 열특성에 대한 연구 (A Study on the Thermal Characteristics of Dry Vacuum Pump with Vertical Screws)

  • 장문석;박재현;김수태;김일곤;조성진
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.67-74
    • /
    • 2015
  • In this study, analysis and experiments were carried out on temperature distributions and thermal deformations in a dry vacuum pump with vertical screws for safe operation. When a vacuum pump is working, it is necessary to get rid of the heat generated by the friction of bearings and the compression of air to prevent the vacuum pump from being damaged by interference between two screws and housing through thermal deformation. Additional cooling was proposed by using oil flow through the inner channel of the rotating axis for lower temperature control of the vacuum pump. Analysis and experimental results were compared in terms of temperature distribution and thermal deformation of the vacuum pump, and two sets of results matched reasonably well. These results for a dry vacuum pump with vertical screws can be used in similar model development and can minimize errors in design and manufacture by providing reasonably accurate prediction in advance.

지열원 히트펌프 시스템의 최적 설계 기법 연구 (Study on the Optimum Design of Ground Source Heat Pumps)

  • 최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.35-42
    • /
    • 2018
  • Among the various ground source heat pump systems, vertical-type heat pump systems have been distributed greatly. Most of the vertical-type ground source heat pump systems have been designed based on the Korean Ministry of Knowledge Economy Announcement in Korea. In this study, the design process of the vertical-type ground source heat pump system in the announcement was analyzed, and the effects of the design parameters on the ground loop heat exchanger were investigated. Borehole thermal conductivity was the highest dominant design parameter for ground loop heat exchangers. The borehole thermal conductivity was changed according to the pipe and grout thermal conductivity. For optimal design of the ground heat pump system, it is highly recommended that the design process in the announcement will be revised to adopt the various tubes and grout which have higher thermal conductivity. In addition, the certification standard for heat pump unit should be revised to develop the heat pump with a small flow rate.

디퓨저를 갖는 수직펌프의 유동해석에 대한 연구 (A Study of Flow Analysis for a Vertical Pump with Diffuser)

  • 정경남;김세진;박편구;김하종
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.216-220
    • /
    • 2001
  • Flow analysis was carried out for two vertical pumps. The geometrical difference of two pumps is the adoption of vaned diffuser. Full pump models were used to simulate the velocity fields of the pumps. Pump head and velocity field were compared to obtain the features of diffuser flow. It was shown that the discontinuity of head curve was predicted and reverse flow could be generated at impeller exit even in the rated flow condition.

  • PDF

수직펌프의 진동해석 (Vibration Analysis of Vertical Pumps)

  • 홍진선
    • 소음진동
    • /
    • 제9권5호
    • /
    • pp.928-935
    • /
    • 1999
  • Vertical pumps are widely used owing to the fact that they occupy small floor space. In this type of pumps, however, the vibrational problems are very important, since, in many cases, they have less stiffness in comparison with lateral pumps. This study presents a simple solution method for calculating the natural frequencies and modes of vertical pumps. In this study, a mode of a vertical pump was developed and the nondimensional parameters for the vibrational characteristics of it were determined. Added mass was calculated for the effects of water and the transfer matrix method was used.

  • PDF

원자력 발전소용 펌프의 내지진해석에 관한 연구 (Seismic Analysis of Nuclear Power Pumps)

  • 손효석;전형식;정희택
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.7-10
    • /
    • 1998
  • The pump safety related to the functions in nuclear power plants must be designed to meet load conditions considering seismic requirements. In order to satisfy both structural integrity and operability of these pumps, the initial step in the seismic qualification is to establish the resonant frequencies of the structure. Applications are made to the design of the vertical and horizontal type pump. Computational results are analyzed with respect to the dynamic characteristics and are compared to the expected design requirements.

  • PDF

대형 수직펌프의 리드공진 문제 (Reed Resonance Problems of Large Vertical Pumps)

  • 최원호;양보석
    • 소음진동
    • /
    • 제4권4호
    • /
    • pp.425-433
    • /
    • 1994
  • A detailed investigation of a reed resonance for a vertical pump design has been conducted. The structural features of this class of pump lead to typical dynamic characteristics. Of particular importance is the fact that the pump assembly is suspended on a high column above the floor with a heavy motor on the top. Considerable amount of mass forces is involved and the vibration can cause damage to the pumps or to the foundation. It is shown that the reed resonance of the pump-motor system plays important role for design and troubleshooting purposes.

  • PDF

CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구 (A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD)

  • 모장오;남구만;김유택;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF

DTMD를 이용한 플랜트 수직 펌프의 진동저감 (Vibration Reduction of Vertical Pumps in Industrial Plants Using Double TMDs)

  • 문영종;최현훈;김현수
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.51-58
    • /
    • 2017
  • The characteristics and effectiveness of double tuned mass dampers (DTMD) have been studied by many researchers. DTMD usually consists of one larger mass block and one smaller mass block. In this study, DTMD was proposed to reduce the vibration of vertical pumps in industrial plants. In order to assess the efficiency of the proposed method, numerical analysis for the simplified vertical pump model with single and double TMDs was carried out. It was also investigated that the effects of optimal TMD parameters such as frequency ratio and damping ratio on dynamic responses of the main structure. According to analysis results, DTMD are more effective to control the vibration of the vertical pump and show good robustness to the change in the stiffness of TMD.

수직축 인-라인 고속 원심펌프용 증속기 개발에 관한 연구 (A Study on the Development of Increasing Gear Box for the High Speed Vertical In-Line Centrifugal Pump)

  • Kim Byung Ok;Lee Dong Hwan
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.343.1-343
    • /
    • 2002
  • In this study, the increasing gear boxes for the high speed vertical in-line centrifugal pump are developed through rotor dynamic analysis. The developed increasing gear boxes are two kinds fur 18000rpm and 25000rpm at the output shaft. The gear sets suitable for high speed and high load are manufactured by investigating AGMA bending strength and AGMA surface strength severely. The rotor dynamic analysis on gear sets and bearings is performed in order to avoid the critical speeds and other troubles. As a result of study, the two increasing gear boxes for the high speed vertical in-line centrifugal pump are designed and maunfactured.

  • PDF