• Title/Summary/Keyword: vertical evacuation

Search Result 45, Processing Time 0.027 seconds

Vertical Evacuation Speed in Stairwell of a High-rise Office Building (업무용 고층건물 계단실의 보행속도에 관한 연구)

  • Joung, Suck-Hwan;Yoon, Myong-Oh
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.13-20
    • /
    • 2015
  • As building height is increased, more careful decisions about the required safe egress time is needed for evacuation. This study analyzed the influence of three training sessions on the vertical speed of evacuation in the high rise building. Evacuation experiments were done in a high-rise office building in Seoul, and we analyzed the vertical evacuation speed as a function of density using a camera. Controlled and uncontrolled total evacuation were compared using the Pathfinder simulation. The process of repeated training, changed the specific stair utilization rate from 6.3% to 39.5%. The vertical evacuation speed as a function of density was analyzed using the equation s = 1.004 ? 0.288D, which is very similar to the equation used in a different study. The total evacuation time of the special controlled total evacuation was reduced by about 25% compared to the simultaneous evacuation.

A Study on Setting the Grade of Vertical Evacuation Rank to Introduce an USN-based Evacuation System into Super High-rise Apartment Housing's (초고층 공동주택의 USN기반 피난시스템 도입을 위한 수직적 피난위계 설정에 관한 연구)

  • Hong, Won-Hwa;Jeon, Gyu-Yeob;Choi, Jun-Ho
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.133-141
    • /
    • 2007
  • The purpose of this study is to secure an evacuation time and to ensure safety by using an Ubiquitous Sensor Network computing when a fire breaks out at a super high-rise apartment housing. A super high-rise apartment housing that is a type of building to solve the problem of separation of the urban function and the phenomenon of hollowing out downtown has been on the increase, high-rise apartment housings occupying 52.7% of whole housings in 2005. However, if a fire breaks out, there would be serious damage since it accommodates many people and facilities as existence of vertical gigantism in the city. The architectural law in force has no clause on it which is universally applicable to general building, it is difficult to be applicable to a densely super high-rise apartment housing and there would be in danger of a resident's evacuation in the fire. Therefore, as a previous study to introduce an USN-based fire-warning facility and evacuation equipment, this study shows the improvement way after analyzing factors that are barriers to evacuaee's behavior of a super high-rise apartment housing and also shows establishment of the grade of vertical evacuation rank by SimuleX, one of the best computer simulation program.

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

An Experimental Study on the Analysis of Evacuation Characteristics Considering the Joining of Occupants in a Building Staircase (건축물 계단실 내 재실자의 합류를 고려한 피난특성 분석에 관한 실험적 연구)

  • Kim, Yun-Seong;Huh, Ye-Rim;Choi, Yun-Ju;Kim, Hye-Won;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.204-205
    • /
    • 2021
  • In the event of a fire in a high-rise building, rapid evacuation through the stairwell is a very important factor in rapid evacuation. However, in the event of an actual fire, most of the occupants evacuate at the same time, resulting in a stay in the stairwell, reducing the evacuation speed. In Korea, conditions for buildings are created to evacuate quickly and safely while introducing performance-oriented designs to solve these problems, but there is no research data related to the evacuation speed due to joining in the event of vertical evacuation. Therefore, in this study, by analyzing the experiment conducted at W University in Japan, the density-speed relationship when staying in the staircase room was derived, and the regression equation was derived based on the results.

  • PDF

A Study on the Design of Evacuation Route at Subway Station Using Simulation Analysis (Simulation 분석을 통한 지하철 역사 피난동선 설계 방안에 관한 연구)

  • Ham, Eun-Gu;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • Since subway fire disaster at Daegu, Korea smoke control system and passengers evacuation distance has been focused to reform. Existing smoke control facilities need to expand volume of ventilation capacity however, the complicate subway station structure can hardly react dispersion of smokes from massive subway cabin fire. Smoke flow at platform level move upward thought vertical stairway and passengers evacuation goes with same direction. The victims of evacuees from subway station fire mainly due to exposure of heat radiation and smoke. The study demonstration the effect of downward evacuates stairway system by separating evacuation route to smoke movement pass way including saving times of evacuation.

RSET Analysis of Factory Workbench Layout Configuration (공장 작업대 배치 형태에 따른 RSET 분석)

  • WOO-GI JANG;DEOK-JIN JANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2023
  • Although fire incidents occur frequently in factory buildings, the focus has primarily been on property damage rather than human casualties. In this study, we conducted an analysis of RSET(Required Safe Egress Time) variation by examining the relocation of workbenchs using evacuation simulations. The results demonstrated that a simple change in workbench placement led to different RSET and variations in the feasibility of evacuation. Specifically, arranging workbenchs in a vertical configuration reduced travel time for workers and minimized total evacuation time. The hybrid layout of "vertical-horizontal" exhibited the shortest RSET, while the "horizontal-vertical" configuration resulted in the longest RSET. These research findings are significant as they provide practical alternatives to decrease RSET in small-scale factories where additional investments beyond essential safety equipment may pose challenges due to budget constraints. However, it is important to note that this study solely focused on comparing RSET while controlling for all other factors, without considering real-life fire simulations. Therefore, further research is necessary to integrate fire simulations and conduct comprehensive assessments of evacuation safety.

A Study for Evacuation Assistance to Vulnerable People by MAS Based Evacuation Simulation (MAS 기반 대피시뮬레이션을 활용한 안전약자 대피지원 개선방안 연구)

  • Jung, Tae Ho;Park, Sang Hyun;Jang, Jae Soon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.121-127
    • /
    • 2017
  • Recently, many patients in a hospital are threatened life by fire disaster. Because many patients like vulnerable people have more evacuation problem than ordinary person. So a patient who can escape by oneself with walking assistance device like crutches or wheelchair and another patient who can't escape by oneself are should be supported safety technologies and service. Earlier research of 'hospital evacuation' led by actual experiments or computer evacuation simulation. Actual experiment is effective to gain credibility of result but it is difficult for patients to experiment repeatedly and it requires consideration for spatial problem and economic problems. Although computer evacuation simulation have been used to solve these problems, almost have concluded only results based on velocity without evacuation device. In this study, evacuation results with support device application or not are analysed used by computer evacuation simulation based on MAS(Multi Agent System). As a result, it is drawn through proof of efficiency of evacuation device in the vertical space like stairs that can improve the evacuation plan for vulnerable people in the hospital.

A Basic Study on the Evacuation Plans of Buildings (건축물의 피난계획에 관한 기초적 연구)

  • 고치원
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.1-6
    • /
    • 2000
  • With the "Fire Protection Building Plan" of the Building Center of Japan as a sample, actual evacuation plans used for large scaled and multi-storied buildings are analyzed. Sufficient number of samples were classified into 6 categories. For room evacuation, time to pass through the exit was the most critical point for larger spaces and movement time in the room was the key for smaller evacuation object zone and less number of evacuees. Seen from the location of fire breakout point, it was witnessed that the numbers of crowding at the exits of the fire escape staircase are serious for floor level evacuation. For vertical traffic line, it was actually proved that time to fire escaping floor is problem of higher buildings. It was also proved that special evacuation methods are in practical use in many buildings in japan.

  • PDF

Evacuation Safety Evaluation According to Slope of the School Ramps

  • Choi, Chang-Jun;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.1
    • /
    • pp.184-196
    • /
    • 2021
  • This study, in order to evaluate the safety of evacuation by comparing and analyzing the RSET according to the slope change of the ramp, which is a vertical evacuation route in case of fire in a high school building, Evacuation simulation was run the Pathfinder program changed the slope of the ramp to 10°, 15°, and 20° for each male students and female students. In the case of female students, it was analyzed that when the final RSET slope was 15°, 25.7 seconds were shorter than when 10°, and 4.2 seconds were shorter than when 20°. Male students also found that when the final RSET slope was 15°, 23.8 seconds were shorter than when 10°, and 5.4 seconds shorter than when 20°. It was analyzed that even if the number of participants was increased and the evacuation simulation was executed, the safety of evacuation could be improved when the slope of the slope is 15° as the RSET when the slope of the slope is 15° is shorter than that of 10° and 20°.

Current Status and Planning Improvement through Case Studies of Nursing Homes in the View of Disaster Safety - Focused on the Cases of Cheongju City, Chungbuk - (재난안전 관점의 노인요양시설 사례연구를 통한 현황 및 개선방안 - 충북 청주시 사례를 중심으로 -)

  • Choi, Yu-Ra;Kim, Mi-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.41-51
    • /
    • 2020
  • As there are the elderly who have difficulty in evacuating themselves, it is necessary to develop architectural and institutional planning for nursing homes that can minimize disaster damage. The purpose of this study was to suggest the improvement plan by grasping the current status of nursing homes on planning aspects such as floor plan type, spatial layout, and evacuation route through 14 case studies in Cheongju city in terms of disaster safety. The results of this study were as follows; the most common plan type was the grouped-corridor type difficulty in securing evacuation routes. The circulation corridor type is need to be considered because it is possible not only to secure evacuation and nursing routes, but also to create a hanging around corridor for the elderly with dementia. Second, if there is a risk of flooding due to the location, the living room should be placed on the 2nd floor or more. In particular, a kitchen should be placed not adjacent to the entrance and the vertical evacuation route. Third, the horizontal evacuation route should be arranged differently depending on the floor plan type. For vertical evacuation routes, it is necessary to install outdoor stairs or ramps considering the evacuation characteristics of the elderly. In addition, the institutional aspects should be considered to ensure the safety of disasters.