• 제목/요약/키워드: vertical earthquake

검색결과 466건 처리시간 0.023초

탄성받침의 강성 변동을 고려한 PSCI 거더 교량의 지진 응답 평가 (Seismic Response Evaluation of PSCI Girder Bridges Considering Stiffness Variation in Elastic Bearings)

  • 윤혜진;조창백;김영진;강준원
    • 한국지진공학회논문집
    • /
    • 제27권4호
    • /
    • pp.187-192
    • /
    • 2023
  • An elastic bearing must be strong against vertical loads and flexible against horizontal loads. However, due to the material characteristics of rubber, it may show variability due to the manufacturing process and environmental factors. If the value applied in the bridge design stage and the actual measured value have different values or if the performance during operation changes, the performance required in the design stage may not be achieved. In this paper, the seismic response of bridges was compared and analyzed by assuming a case where quality deviation occurs during construction compared to the design value for elastic bearings, which have not only always served as traditional bearings but also have had many applications in recent seismic reinforcement. The bearing's vertical stiffness and shear stiffness deviation were considered separately for the quality deviation. In order to investigate the seismic response, a time history analysis was performed using artificial seismic waves. The results confirmed that the change in the bearing's shear stiffness affects the natural period and response of the structure.

Vertical equipment isolation using piezoelectric inertial-type isolation system

  • Lu, Lyan-Ywan;Lin, Ging-Long;Chen, Yi-Siang;Hsiao, Kun-An
    • Smart Structures and Systems
    • /
    • 제26권2호
    • /
    • pp.195-211
    • /
    • 2020
  • Among anti-seismic technologies, base isolation is a very effective means of mitigating damage to structural and nonstructural components, such as equipment. However, most seismic isolation systems are designed for mitigating only horizontal seismic responses because the realization of a vertical isolation system (VIS) is difficult. The difficulty is primarily due to conflicting isolation stiffness demands in the static and dynamic states for a VIS, which requires sufficient rigidity to support the self-weight of the isolated object in the static state, but sufficient flexibility to lengthen the isolation period and uncouple the ground motion in the dynamic state. To overcome this problem, a semi-active VIS, called the piezoelectric inertia-type vertical isolation system (PIVIS), is proposed in this study. PIVIS is composed of a piezoelectric friction damper (PFD) and a leverage mechanism with a counterweight. The counterweight provides an uplifting force in the static state and an extra inertial force in the dynamic state; therefore, the effective vertical stiffness of PIVIS is higher in the static state and lower in the dynamic state. The PFD provides a controllable friction force for PIVIS to further prevent its excessive displacement. For experimental verification, a shaking table test was conducted on a prototype PIVIS controlled by a simple controller. The experimental results well agree with the theoretical results. To further investigate the isolation performance of PIVIS, the seismic responses of PIVIS were simulated numerically by considering 14 vertical ground motions with different characteristics. The responses of PIVIS were compared with those of a traditional VIS and a passive system (PIVIS without control). The numerical results demonstrate that compared with the traditional and passive systems, PIVIS can effectively suppress isolation displacement in all kinds of earthquake with various peak ground accelerations and frequency content while maintaining its isolation efficiency. The proposed system is particularly effective for near-fault earthquakes with long-period components, for which it prevents resonant-like motion.

Angle형 기기 정착부의 성능평가에 관한 실험적 연구 (A study on the experimental evaluation of an Angle Type Anchorage System)

  • 김강식;서용표;유원진;김갑순
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.266-274
    • /
    • 2002
  • A typical case where the effects of prying in the base angle type anchorage system with expansion bolt. This connection consists of an angle which is attathed to an equipment cabinet and bolted to a concrete slab via an expantion bolt. A seismic analysis of the cabinet may indicate a vertical load, P, transferred to the vertical leg of the angle due to overturning of the cabinet. Due to the eccentricity, b(e), and the continuous beam action in the base member, the load resisted by the bolt will be amplified by a factor λ. Thus, in this study, experimental evaluation of the anchorage system is executed.

  • PDF

양산단층 북부 유리계 일대의 신기 단층운동 소고 (Discussion on the Quaternary fault movement at Yugye-ri area in the northern part of Yangsan Fault)

  • 경재복
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.66-73
    • /
    • 2001
  • Yangsan fault in the southeastern part of Korean peninsula has been locally reactivated along a prexisted fault during the late Pleistocene time. Geomorphological evidence of the reactivation is revealed at the northern segment(Yugye-ri, Tosung-ri areas) of the Yangsan fault. The reactivation is distinctively characterized by fault gouge and fracture zone with high frequency in the Yugye-ri area. Obique slip separation of the area is about three meters of the middle terrace. The cumulative vertical displacement is recognized after the formation of the middle terrace. Age of the reactivated faulting is constrained to during the formation of dissected valley deposits. Average vertical slip based on paleo-event is inferred to about 0.5-0.7 meter in this area.

  • PDF

축소규모 고감쇠 및 납삽입형 면진베어링에 대한 특성시험고찰 (Characteristic Tests of Reduced-Scale High Damping and Lead Rubber Bearings)

  • 유봉;이재한;구경회
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.175-182
    • /
    • 1997
  • The characteristic tests of reduced-scale high damping and lead rubber bearings are performed by changing the shear displacements and the vertical loads. The test frequency is 0.5Hz. Test results show that the shear stiffnesses obtained for both bearings are less than target values, but the damping values are greater than the targets. The shear stiffness and damping of lead are larger than those of high damping bearings. The shear-deformation characteristic values such as stiffness, damping and yield load values are changed according to the level of design vertical loads.

  • PDF

경상분지에서의 수직변위값에 대한 최대 스펙트럼 진폭의 감쇠 (Attenuation of Peak Spectral Amplitude for the Vertical Displacement in the Kyungsang Basin)

  • 김성균
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.45-51
    • /
    • 1999
  • The attenuations of peak vertical displacements are studies using a conventional least squeare regression technique for microearthquakes occurred in the Kyungsang Basin southeastern Korea. The regression model applied to bandpass-fitered ground motion data includes parameters to account for geometric spreading anelastic attenuation depending on frequency source size and station site effects. Thirty nine displacement traces obtained by integrating velocity records for six shallow local microearthquakes are used to determine attenuation characteristics in the Basin. The regression result of the peak amplitude data leads to Q(f)=59.9 {{{{ {f }^{0.955 } }} for 1.5Hz$\leq$ f $\leq$ 25 Hz. It appears that the anelastic attenuation in the Kyungsang Basin is greater than that in the Western North America Area.

  • PDF

수신함수를 이용한 관측소 하부의 지진파 속도구조 (Crustal structure beneath broadband seismic station using receiver function)

  • 박윤경;전정수;김성균
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.45-49
    • /
    • 2003
  • The velocity structure beneath the CHNB broadband station is determined by receiver function analysis using by from teleseismic P waveforms. The detailed broadband receiver functions are obtained by stacking method for source-equalized vertical, radial and tangential components of teleseismic P waveforms. A time domain inversion uses the stacked radial receiver function to determine vertical P wave velocity structure beneath the station. The crustal velocity structures beneath the stations are estimated using the receiver function inversion method in the case at the crustal model parameterized by many thin, flat-tying, homogeneous layers. The result of crust at model inversion shows the crustal velocity structure beneath the CHNB station varies smoothly with increasing depth, and there are six discontinuity around 2.5km, 6.25km, 12.5km, 22.5km and 27.5km depth, with Moho discontinuity at about 32.5km depth.

  • PDF

수신함수를 이용한 관측소 하부의 지진파 속도구조 (2) (Crustal structure beneath broadband seismic station using receiver function (2))

  • 박윤경;전정수;김성균
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.3-7
    • /
    • 2003
  • The velocity structure beneath the CHNB broadband station is determined by receiver function analysis using by from teleseismic P waveforms. The detailed broadband receiver functions are obtained by stacking method for source-equalized vertical, radial and tangential components of teleseismic P waveforms. A time domain inversion uses the stacked radial receiver function to determine vertical P wave velocity structure beneath the station. The crustal velocity structures beneath the stations are estimated using the receiver function inversion method in the case at the crustal model parameterized by many thin, flat-lying, homogeneous layers. Events divide into 4 groups. four azimuths corresponding to events in group a(southwest), b(south), c(southeast), d(northeast). The result of crust at model inversion shows the crustal velocity structure beneath the CHNB station varies smoothly with increasing depth. The conard discontinuity lies around 18 km and moho discontinuity lies range from 30 to 34 km.

  • PDF

원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구 (Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System)

  • 함경원;이경진;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF

마찰진자형 면진베어링의 특성 연구 (A study on the characteristics of friction pendulum isolation bearings)

  • 김영중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.407-414
    • /
    • 2000
  • The friction pendulum type seismic isolation system (FPS) has been developed to provide a simple and effective way to achieve earthquake resistance for buildings . The major advantages are: the isolation frequency can be easily achieved by designing a curvature of the surface and does not depend on the supported weight of a structure. The function of carrying vertical load is separated to the function of providing horizontal stiffness. Next the friction provides sufficient energy dissipation to protect the structure from earthquake response and resistance to the weak external disturbances such as wind load and ground vibrations due to traffic. In this paper, the friction coefficients are evaluated from number of experiments on the FPS test specimens. The relations between friction coefficient and the test waveform, velocity, and pressure are reviewed and further works are discussed.

  • PDF